Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C30000XZ
32
When the laser key switch hits REM mode, pin 8/9 must be shorted to the main control board to
power up.
e) Remote Mains Power Up
This signal is used to enable mains power-up via the XP2 interface.
Figure 23 XP2 remote main power up wiring diagram.
f) Control board is powered up output
This signal is relay output, the main control board power on the relay suction.
4.4.2 Hard Wiring XP1
64 pin hard wire interface, control signal input and output interface of laser in remote mode. Input
high level is greater than 18V valid, input low level is less than 3V valid. Specific interface definitions are
shown in Table 7 below.
Table 7 XP1 Hardwire interface definitions.
No. XP1
Interface Requirements
Type
Description
Pin
number
Pin definition
XP1
A1
Laser request
signal
Input signal
Import signal, request laser, this bit is valid before the
laser receives other instructions
PIN
PIN
Dipswitch
Содержание RFL-C30000XZ
Страница 1: ...RFL C30000XZ JS01 1 S 85 RFL C30000XZ...
Страница 2: ...RFL C30000XZ Continuous Wave Fiber Laser User Guide...
Страница 3: ...Wuhan Raycus Fiber Laser Technologies Co Ltd...
Страница 4: ......