background image

EN

HEATING CABLE & PIPE

RESET

SERVICE 

STATUS

14 : 17

SELECT CABLE TYPE

SELECT PIPE DIAMETER

SELECT INSULATION THICKNESS

SELECT AMBIENT TEMPERATURE 

SELECT BOILER SENSOR

SELECT BOILER CUT-OFF TEMPS.

HWAT-M

DN 25

40 MM

20°C

ON

35/85°C

HEATING CABLE & PIPE

Selection of 

parameters

Every parameter line shows the actual value /attribute for 

each parameter.

HWAT cable

Select the type of cable used in your installation  

(HWAT-L, HWAT-M, HWAT-R).

Pipe  

diameter

Set the pipe diameter. You can change the value from DN 

15

 mm up to DN 

125

.

Insulation 

thickness

Set the insulation thickness. You can change the value 

from 

9

 to 

130

 mm, with the pipe diameter as the limiting 

value.

Boiler sensor

Activate/deactivate a connected boiler sensor by clicking 

on ON/OFF. The external temperature sensor measures 

the boiler temperature. The trace boiler setting is 

included to ensure that the heating cable temperature 

does not exceed the boiler temperature. The HWAT-ECO 

memorizes the highest measured temperature over 

the last 

24

 hours. If the boiler temperature is too low, 

the maximum temperature is lowered to the boiler 

temperature minus the trace temperature. In this case 

the green trace boiler LED will be on.

Boiler low  

temperature 

limit

You can determine the low temperature limit. If the 

boiler temperature reaches this value, the unit will 

switch off the heating system in order to fulfil hygienic 

requirements and avoid energy waste.

Boiler high 

temperature 

limit

You can determine the high temperature limit.  

If this value is reached the unit will switch off  

the heating system to avoid scalding.

Pipe sensor 

Activate/deactivate a connected pipe sensor by pressing 

ON/OFF. The pipe sensor monitors the pipe temperature 

and needs to be installed close to the furthest point in 

the pipe distribution network.

Pipe sensor 

low  

temperature 

limit

You can determine the low temperature limit.

When the value is reached a warning will appear on the 

screen but will not interrupt the unit’s functioning. The 

info status screen will show the actual pipe temperature.

Pipe sensor 

high  

temperature 

limit

You can determine the high temperature limit. A warning 

will appear on the screen when the value is reached but 

will not interrupt the unit’s functioning.

14 

|

  nVent.com/RAYCHEM

Содержание nVent HWAT-ECO V5 (EU)

Страница 1: ...HWAT ECO V5 EU Firmware version 1 1 3 or higher Installation operation and maintenance manual HWAT ECO V5...

Страница 2: ...Product overview 3 2 Installation instructions 4 3 Installation notes 9 4 Operation 11 5 Parameter settings default 16 6 Technical specifications 16 Appendix 21 2 nVent com RAYCHEM Electrical schemes...

Страница 3: ...EN HWAT ECO V5 HWAT ECO V5 HWAT ECO V5 HWAT ECO V5 1x 1x 2x M25 2x M20 PCN 1244 020365 PCN 1244 015847 2x 2x 1x 1x 1x 1x 1x A B C 1 PRODUCT OVERVIEW nVent com RAYCHEM 3...

Страница 4: ...EN HWAT ECO V5 150 mm 1A 1B 5 2 3 2 INSTALLATION INSTRUCTIONS 4 nVent com RAYCHEM...

Страница 5: ...EN 1 2 A B C 4 5 6 nVent com RAYCHEM 5...

Страница 6: ...EN 7 8 9 6 nVent com RAYCHEM...

Страница 7: ...EN CLICK 10 11 12 nVent com RAYCHEM 7...

Страница 8: ...EN 30mA RCD C20A ON 15 HWAT E CO V5 13 14 8 nVent com RAYCHEM...

Страница 9: ...eveloped for operation with the self regulating heating cables nVent RAYCHEM HWAT R HWAT M and HWAT L The hot water temperature maintenance system is a comfort system providing instant hot water at th...

Страница 10: ...ckup 10 days Clock accuracy A variation of 10 minutes per year is possible Settings All settings are stored in non volatile memory Operating temperature 0 C to 40 C ambient Selectable temperature 37 C...

Страница 11: ...unit is automatically executing a connection check It will check the heating cable connection boiler sensor and pipe sensor connection A connection of the unit to an external relay needs to be confir...

Страница 12: ...ture is the selected maintain temperature Test programme start The test programme runs for 30 minutes during which all parameters will be ignored to check heating cable and connection on site You can...

Страница 13: ...ER SELECT PROGR PROGRAM TIM SELECT CABLE TYPE SELECT PIPE DIAMETER SELECT INSULATION THICKNESS SELECT AMBIENT TEMPERATURE SELECT BOILER SENSOR SELECT BOILER CUT OFF TEMPS HWAT M DN 25 40 MM 20 C ON 35...

Страница 14: ...mperature is too low the maximum temperature is lowered to the boiler temperature minus the trace temperature In this case the green trace boiler LED will be on Boiler low temperature limit You can de...

Страница 15: ...ER TEMP PROGRAMMING ER EMP 0 SELECT LANGUAGE SELECT COUNTRY SELECT DATE SELECT TIME SELECT ALARM GENERAL SETTING SELECT SAVING TIME ENGLISH GERMANY 01 10 2017 14 17 OFF ON 14 17 14 17 14 17 14 17 14 1...

Страница 16: ...Language English Country Not pre defined to be selected Date 01 01 2017 or last saved date Time 00 00 or last saved time Building programme Not pre defined to be selected Heating cable type Not pre d...

Страница 17: ...HOTEL WEEKDAY 10 29 00 01 02 03 04 21 22 23 12 13 14 15 16 18 19 05 07 09 11 20 17 06 08 10 Nursing home Weekday Weekend HEAT UP TIME IN HOUR HOSPITAL WEEKDAY 10 30 00 01 02 03 04 21 22 23 12 13 14 1...

Страница 18: ...0 30 00 01 02 03 04 21 22 23 12 13 14 15 18 19 05 07 09 11 20 17 06 08 10 16 Sport center Weekday Weekend HEAT UP TIME IN HOUR SPORT CENTER WEEKDAY 10 29 00 01 02 03 04 21 22 23 12 13 14 15 16 18 19 0...

Страница 19: ...sor failure Sensor has not been installed Sensor or sensor cable defect only when water heater sensor On is selected Check Sensor and Boiler temperature E 3 2 BOILER TEMP HIGH Water heater temperature...

Страница 20: ...error provide the exact error number cable type cable length and the setpoint temperature E 6 5 INTERNAL ERROR Internal error Disconnect HWAT ECO controller and replace unit When reporting this error...

Страница 21: ...er your 4 digit password If you forgot your password enter the backup password 3000 to unlock the controller See key lock Seeing 3 dots one by one on the screen Pushing the screen for 30 seconds cause...

Страница 22: ...AC 30 mA MAX C 20 A HWAT ECO S1 Pipe Sensor Rohrleitungsf hler R rsensor Potrubn idlo Sonde du tuyau Sensore tubazione Leidingsensor Czujnik temperatury rury S2 Boiler Sensor Boilerf hler Kedelsensor...

Страница 23: ...EN ELECTRICAL SCHEME K1 L3 N L1 L2 30 mA T L L N N PE PE COM NO NC S1 S1 GND S2 S2 GND Temperature sensors NTC Alarm 1 A 30 VDC 0 5 A 125 VAC HWAT HWAT L M R ECO MAX C 20 A nVent com RAYCHEM 23...

Страница 24: ...l 39 02 577 61 51 Fax 39 02 577 61 55 28 salesit nVent com Lietuva Latvija Eesti Tel 370 5 2136633 Fax 370 5 2330084 info baltic nVent com Magyarorsz g Tel 36 1 253 7617 Fax 36 1 253 7618 saleshu nVen...

Отзывы: