3.1.6 Country
Select a country in this menu. This is used to set the default values for
pipe diameter and insulation thickness. For more information see
Appendix 5.1, page 24.
3.1.7 Maintain temperature
The maintain temperature is the water temperature that you set for normal
use. The temperature can be selected using the up/down arrow keys.
The minimum temperature is 41˚C or the economy temperature, whichever
is higher. The maximum temperature depends on cable type, pipe thick-
ness, insulation thickness and ambient temperature (see Fig. 3, page 12).
The programmed maintain temperature can be displayed by pushing the
escape key once the system is in operation.
3.1.8 Economy temperature
The economy temperature is the water temperature for periods during
which hot water is not usually tapped (at night) or when lots of hot water
is tapped (peak period). The temperature can be selected using the
up/down arrow keys. The minimum temperature is 41˚C and the maximum
temperature is the selected maintain temperature.
3.1.9 Pre-Programs
The HWAT-ECO has 8 default timer programs. See 5.5.2 Diagrams,
page 35 for more information. A pre-program can be selected using the
up/down arrow keys. Press Enter to confirm your choice. HWAT-ECO takes
a few seconds to copy the default program to the internal memory. During
this time a row of dots will show in the display.
Fig. 5
Program name
Diagram number
Building type
Constant
I - 0
Constant temperature
Apartments
I - 1
Apartment block
Family Home
I - 2
Family home
Prison
I - 3
Prison / Barracks
Hospital
I - 4
Hospital
Nursing Home
I - 5
Nursing home
Hotel
I - 6
Hotel
Sport Centre
I - 7
Sport centre / Swimming pool
Convalesc. Home
I - 8
Convalescent home
esc
Tyco C 9278e HWAT-ECO 22.02.2002 14:12 Page 15
Содержание HWAT-ECO
Страница 2: ...3 148 mm 1 2 A B C Tyco C 9278e HWAT ECO 22 02 2002 14 12 Page 2 ...
Страница 28: ...28 Fig 10 Example Fig 11 Tyco C 9278e HWAT ECO 22 02 2002 14 12 Page 28 ...
Страница 29: ...29 Fig 12 Tyco C 9278e HWAT ECO 22 02 2002 14 12 Page 29 ...
Страница 97: ...Fig 10 Exemple Fig 11 97 Tyco C 9278f HWAT ECO 22 02 2002 14 10 Page 97 ...
Страница 98: ...Fig 12 98 Tyco C 9278f HWAT ECO 22 02 2002 14 10 Page 98 ...