4.9
DOMESTIC WATER
4.9.1
The domestic hot water must be in accor-
dance with the relevant recommendations
of BS 5546. Copper tubing to BS 2871.1 is
recommended for water carrying pipework
and MUST be used for pipework carrying
potable water..
4.10
ELECTRICAL SUPPLY
Warning: this appliance must be earthed
4.10.1
External wiring to the appliance must be
carried out by a competent person and be in
accordance with the current I.E.E. Regula-
tions and local regulations which apply.
The Ravenheat boiler is supplied for con-
nection to a 230 V - 50 Hz single phase
supply. The supply
must be fused at 3 A.
NOTE: The method of connection to the
electricity supply MUST facilitate complete
electrical isolation of the appliance, by the
use of a fused, double pole isolator, having
a contact separation of at least 3 mm in all
poles. The point of connection to the elec-
tricity supply must be readily accessible and
adjacent to the appliance except, where the
appliance is installed in a bathroom, this
MUST be sited outside the bathroom.
SECTION 5 INSTALLATION
5.1
WARNING
5.1.1
It is MOST IMPORTANT that this appliance
is installed in a VERTICAL POSITION, with
the flue air duct passing through the wall in
a HORIZONTAL PLANE. A minor deviation
from the horizontal is acceptable, provided
that this results in a downward slope of the
flue/air duct away from the combination
boiler.
Flue box containing (Fig. 12):
Standard Flue Assembly
57 - Flue bend assembly
59 - Rubber seal 0 60
60 - Air intake duct
61 - Flue exhaust duct
62 - Terminal
65 - Pipe centering spring
66 - Flue sample point
5.2
DELIVERY
5.2.1
The appliance will arrive on site in three
cartons:
Boiler carton containing:
a) boiler fully assembled
b) installation instructions and
user instructions
c) white paper template
d) terminal cover plate (Fig. 12 item 127)
g) - 4 coach bolts and wall plugs
- screws and dowels
h) header gasket (Fig. 12 item 56)
Valve pack carton containing:
a) 2-22 mm compression ball valves
(heating)
b) 1-1 5 mm compression ball valve
(with drain screw for domestic cold
water inlet)
c) 1-1/2" BSP Union gas cock
d) Polythene bag containing
2 15 mm flanged copper tails complete
with 1/2" brass nuts and washers
- 2 22 mm flanged copper tails complete
with 3/4" brass nuts and washers
Fig. 10
For vertical flue
system see sect. 5.7.12
(Minimum vertical 1100 mm)
Fig. 12