background image

3

7.

Wireless Status

 - If a Slingshot Field Hub™ is connected to the Viper Pro 

field computer, the status of wireless communications is accessible by touching 
the wireless communication status indicator.

8.

Booms

 - The Booms area displays the status of boom or implement sections. 

A section display character will display green when on, grey when off. Touch in 
this area to configure the optional AccuBoom system.

Note:  

Boom sections controlled by the optional AccuBoom system will display 
with a blue background.

9.

Application Rates

 - Target rate (R

T

) and actual rate (R

A

).

Touch in this area to set or change rates (available for CAN or serial systems 
only).

10.

GPS Status Indicator

 

- Status of DGPS messages and the current source 

of GPS corrections are displayed in this area. Touch this area for additional 
GPS information.

11.

Product Control Status

 - Product Control Status of a Raven serial 

console or a Raven CAN system displays in this area. Touch this area to view or 
modify Product Control settings.

12.

SmarTrax Status Display

 - If an optional SmarTrax system is installed 

with the Viper Pro, this area displays the status of SmarTrax system.

13.

AutoBoom Status Display

 - If an optional Glide Series AutoBoom 

system is installed with the Viper Pro system, this area displays the status of 
AutoBoom system. Touch this area to enable/disable or configure AutoBoom 
system.

Map Tools

Map 

Symbols

Description

When the 

Cursor Lock

 

icon

 is active, Viper will automatically pan 

the display to keep the vehicle indicator on screen. Select this 

mode when running a job.

The 

Information icon

 is available on the Main tab when a job is 

not in progress, or on the Scout tab during an active job. Select this 

icon and touch the map area to view map information.

The 

Prescription icon

 is only available on the Rx tab (if a 

prescription map had been previously loaded) or the Cov tab.

The 

Pan icon

 is used to manually pan the map information up/

down or left/right.

Touch the 

Zoom Out icon

 and then select the map area to view a 

larger area on the map.

Touch the 

Zoom In icon

 and then select the map area to view a 

more detailed area on the map.

Содержание Viper Pro

Страница 1: ...Software Version 3 10 Viper Pro Quick Reference Guide...

Страница 2: ...e sharp objects or harsh chemicals on the field computer touch screen as they may damage the display Don t use the USB ports to charge mobile devices such as phones tablets or mp3 players Basic Startu...

Страница 3: ...rmation based on the selected tab Touch the tabs along the right side of the Viper Pro display to view application information maps or guidance information 5 Tabs Used to access available features fun...

Страница 4: ...or modify Product Control settings 12 SmarTrax Status Display If an optional SmarTrax system is installed with the Viper Pro this area displays the status of SmarTrax system 13 AutoBoom Status Display...

Страница 5: ...The upper portion of the Feature Settings area displays the selected product node or control channel Use the drop down selection box to select other available control channels and display the program...

Страница 6: ...ve and application types used to apply the product Touch in this area to select a different valve type and or application type 7 Tally Registers Touch this button to access the tally registers Also di...

Страница 7: ...ad Profile 2 Select a profile from the list and touch OK 3 Touch the OK button on the Load Profile prompt The Shutdown Viper prompt will be displayed 4 Select the Exit to Menu button and select the ap...

Страница 8: ...s may only be modified on the Viper Pro if the field computer is set as the CANbus controller Product density and spreader constant may also be modified when controlling a granular application system...

Страница 9: ...8 Starting a New AgX Job 1 Select Menu Start Job then New AgX Job 2 Select from the available grower farm and field lists to locate the prepopulated job information for the next job...

Страница 10: ...Do not select control channels for these functions during the job setup process To deselect a channel touch a selected channel again to remove the channel from the job setup process Any deselected cha...

Страница 11: ...nabled and enter the number of products if product application is enabled Note If none of the job options are enabled touch the OK button on the New Job screen to begin the job 3 If products should be...

Страница 12: ...and proceed with the steps below Otherwise touch OK a Touch Browse to find an Rx Map file b Select the desired map file and touch OK c Select the column heading from the dbf file to use for rate info...

Страница 13: ...b From File then Add to Job 2 Select an Existing Job and touch OK Then touch Menu and the Cont Job button to resume application within the job Note The Viper Pro will not log application or location i...

Страница 14: ...button to set the B point of the A B Line The set A B Line appears on the screen in blue To save the currently displayed A B Line 1 With the Guide tab selected touch the Guide Menu icon 2 Touch the S...

Страница 15: ...usly entered values touch Reset above Tnk Vol 4 To reset individual nodes touch Next 5 On the Odometer screen touch Next 6 Type in a value for the Tank Volume and then touch Set 7 Touch Next Do the sa...

Страница 16: ...Feature screen displays Select Field Boundary and select the point entry and offset your options and touch OK Note The Field Boundary will automatically close if the machine comes within one boom wid...

Страница 17: ...ceivers except for the RPR 400 RPR 410 and the Phoenix 300 or when not using the guidance in the Viper Pro to control a SmarTrax SmartSteer system Select Generic GPS when connected to a Raven RPR 400...

Страница 18: ...ct the desired aggressiveness setting and touch OK Note The aggressiveness factor setting uses a percentage of the look ahead times to adjust the responsiveness of the AccuBoom system If a SwitchPro i...

Страница 19: ...e center of the AutoBoom Area 2 Select AutoBoom ON and UltraGlide for mode 3 Touch the Calibrate button 4 Touch Cal Left and wait for left boom calibration to complete then touch Cal Right and wait fo...

Страница 20: ...ch the Calibrate button Note The AutoBoom Control screen in PowerGlide Plus mode will appear similar to the screens shown in the previous UltraGlide section Refer to the UltraGlide section to locate t...

Страница 21: ...uch Menu Setup then Lightbar 2 Select a Lightbar to use 3 Select Send Guidance Message when using the Viper Pro to provide guidance information to a SmarTrax SmartSteer system 4 Touch Next to set it u...

Страница 22: ...e Buttons with arrows go to sub menus Buttons without arrows go directly to selection screens MAIN MENU START JOB SUBMENU FROM FILE SUBMENU SETUP SUBMENU MAPS MENU STREET MAP MENU RX MAP SUB MENU LOCA...

Страница 23: ...22...

Страница 24: ...copyright laws Raven Industries Applied Technology Division Toll Free U S and Canada 800 243 5435 P O Box 5107 or Outside the U S 1 605 575 0722 Sioux Falls SD 57117 5107 Fax 605 331 0426 www ravenpr...

Отзывы: