Страница 1: ...SmartYield Pro Installation Manual P N 016 0171 566 Rev C 12 15 E26333 Copyright 2015 ...

Страница 2: ...nsible for any modifications or repairs made outside our facilities nor damages resulting from inadequate maintenance of this system As with all wireless and satellite signals several factors may affect the availability and accuracy of wireless and satellite navigation and correction services e g GPS GNSS SBAS etc Therefore Raven Industries cannot guarantee the accuracy integrity continuity or ava...

Страница 3: ...sion Plates 18 Bolt on Paddle Chains 18 Riveted Paddle Chains 19 Chapter 4 Moisture Sensor Installation 21 Moisture Sensor Installation Recommendations 21 Installation on the Clean Out Door 21 Clean Out Door Mounting 22 Installation on the Grain Tank Loading Auger 23 Grain Tank Loading Auger Mounting 23 Moisture Sensor Revisions 24 Chapter 5 Header Cutout Switch Installation 25 Factory Rotary Swit...

Страница 4: ...Table of Contents ii SmartYield Pro Installation Manual CAN and Power Connections 31 Chapter 7 Envizio Pro Series Connection 33 ...

Страница 5: ... Pro observe the following safety measures Be alert and aware of surroundings at all times Do not operate any agricultural equipment while under the influence of alcohol or an illegal substance Please review the operation and safety instructions included with the implement and or controller Electrical Safety Do not reverse power leads Doing so could cause severe damage to equipment Always make sur...

Страница 6: ...rating of harness components Wiring should be protected or shielded if it needs to route near hot temperatures beyond harness component specifications Harnessing should not have sharp bends Allow sufficient clearance from machine component operational zones such as Drive shafts universal joints and hitches i e 3 point hitch Pulleys gears sprockets Deflection and backlash of belts and chains Adjust...

Страница 7: ... Sheared or flame cut edges Edges of machined surfaces Fastener threads or cap screw heads Ends of adjustable hose clamps Routing should not allow hoses to Hang below the unit Have the potential to become damaged due to exposure to the exterior environment i e tree limbs debris attachments Be placed in areas of or in contact with machine components which develop temperatures higher than the temper...

Страница 8: ...lamp hoses securely to force controlled movement to occur in the desired hose section Avoid sharp twisting or flexing of hoses in short distances Protect hoses from Foreign objects such as rocks that may fall or be thrown by the unit Buildup of dirt mud snow ice submersion in water and oil Tree limbs brush and debris Damage where service personnel or operators might step or use as a grab bar Damag...

Страница 9: ...Yield Pro system may be used with the following Raven devices Envizio Pro Envizio Pro II or Envizio Pro XL Additional settings and features of the SmartYield Pro system are detailed in the SmartYield Pro Calibration and Operation Manual Installation Overview Installation of the SmartYield Pro system varies depending upon the specific machine make model and model year Despite variations the install...

Страница 10: ...tents SmartYield Pro Kit SmartYield to SmartYield Pro Update Kit Item Description Part Number 117 9000 002 117 9000 003 Node SmartYield Pro 063 9000 002 1 1 Cable SmartYield Pro 115 9000 010 1 1 Kit Node Mounting 117 0171 299 1 1 Sensors Wired Pair Optical Yield 063 9000 006 1 Assembly Yield Sensor Optical Lens 063 9000 001 2 Bracket Yield Sensor Mounting 107 0172 134 2 Bracket Universal Yield Sen...

Страница 11: ... the sensor location towards the lift side may eliminate the need for extension plates FIGURE 1 Angled Paddle Mounting Brackets Refer to the SmartYield Pro Calibration and Operation Manual for details on the calibration and to help determine if extension plates are necessary Refer to Yield Sensor Paddle Extension Plates on page 18 for additional information on installing extension plates TABLE 2 P...

Страница 12: ... 4 Hand File 321 0000 433 1 Item Description Qty Saw 7 8 Hole 1 Saw 3 1 4 Hole 1 Drill 1 4 High Speed Pilot 1 Drill 1 4 Pilot for Bimetal Hole Saw 1 Header Height Sensor Amp SuperSeal Tee P N 115 9000 016 Used on certain models of Gleaner Massey Ferguson Claas and Challenger Harvesters Header Height Sensor Deutsch DTM Tee P N 115 9000 018 Used on certain models of Case IH Harvesters Header Height ...

Страница 13: ...gn up for e mail alerts to receive notice when updates for your Raven products are available on the Raven web site At Raven Industries we strive to make your experience with our products as rewarding as possible One way to improve this experience is to provide us with feedback on this manual Your feedback will help shape the future of our product documentation and the overall service we provide We...

Страница 14: ...Chapter 2 10 SmartYield Pro Installation Manual ...

Страница 15: ...elevator by a measurement X specific for each make and model of harvester Refer to the Yield Sensor Locations section on page 13 for a table of yield sensor offset values Note The X measurement must be made perpendicular from the side wall on the lift side of the clean grain elevator If your specific harvester make and model is not listed contact a local Raven dealer or the Raven technical support...

Страница 16: ...ator Ensure the yield sensors and mounting brackets will not interfere with or be struck during normal equipment operation It may be necessary to assemble the yield sensors and brackets and rough out the yield sensor installation to verify clearances It may be necessary to disconnect or move some components on some machine makes or models to allow for yield sensor installation Contact a local deal...

Страница 17: ...el The offset value X is measured from the wall on the lift side of the clean grain elevator TABLE 1 Harvester Make and Model Offset Measurements Make Model X Measurement Inches Millimeters Case IH 1460 1 3 8 35 1660 2166 1 9 16 40 1680 2 3 8 60 2188 2388 2 3 8 inside 1 15 16 outside 60 inside 50 outside Claas Dominator 86 96 98 1 9 16 40 Dominator 106 108 118 204 218 Lexion Tucano 1 3 4 45 Domina...

Страница 18: ...perly aligned before drilling any holes in the clean grain elevator To mount the yield sensors using the mounting brackets 1 Insert a 1 4 bolt P N 311 0049 103 through the recessed side of the ceramic magnet assembly P N 418 0000 013 The threaded side of the bolt should extend past the flat side of the magnet assembly 2 Insert the bolt through the predrilled holes or slot in the mounting bracket t...

Страница 19: ... Check for any existing components which may interfere with or damage the yield sensors before proceeding Adjust or relocate the yield sensor mounting locations as necessary 6 Measure from the lift side to the desired sensor location Mark the same distance on the opposite side to align the yield sensor mounting points If necessary review the Yield Sensor Locations section on page 13 for machine sp...

Страница 20: ... drilling the yield sensor holes Note Hole saw bits are designed for use at low speeds Adjust the drill speed to the lowest speed setting For elevators with limited access to the inside wall use an extended drill bit to drill the sensor hole on the inside elevator wall if the dimensions of the grain elevator allow Be careful to level the bit or drill to ensure that the sensors will align Mounting ...

Страница 21: ...ush with the magnets on the bracket 6 Align the sensor eye with the holes drilled in the clean grain elevator and carefully set the brackets in place 7 Adjust the sensor depth to secure the lens assembly firmly to the elevator wall and tighten the jam nuts It is not necessary to exert significant force against the elevator wall When properly adjusted the lens assembly should be flush with the elev...

Страница 22: ...details on the calibration and to help determine if tabs are necessary for your specific harvester On models with the elevator paddles riveted to the elevator chain weld the tabs to the paddle brackets Bolt on Paddle Chains To attach the paddle extension plates to bolt on elevator paddles 1 Open the access panel or clean out door in the bottom of the clean grain elevator 2 Manually operate the ele...

Страница 23: ... arc welder to tack the extension plates at the rivet holding the paddle onto the chain The plate weld should not bind or inhibit operation of the chain Important Disconnect battery cables to avoid damaging machine electronics 4 Manually advance the elevator to the next paddle and repeat the above process for each paddle on the clean grain elevator Convert the Paddle to Bolt on Mounting 1 Use a sm...

Страница 24: ...Chapter 3 20 SmartYield Pro Installation Manual ...

Страница 25: ...oftware version 2 01 14 or higher Installation on the Clean Out Door Keep the following items in mind when selecting a location to mount the moisture sensor Mount the moisture sensor to a clean grain elevator or the grain tank loading auger When mounting to the clean grain elevator this location will allow easy access to clean off the moisture sensor when harvesting especially dirty or wet crops F...

Страница 26: ...ole in the clean out door for the moisture sensor Double check clearances with the sensor on the clean grain elevator before drilling any holes Note Hole saw bits are designed to be used at low speeds Adjust the drill to the lowest speed setting FIGURE 1 Example of Moisture Sensor Mounting Location and Hole Drilling 5 Set the moisture sensor in the hole and use the sensor housing to mark the posit...

Страница 27: ...nsor Use the parts provided in the auger moisture sensor kit P N 117 9000 012 to mount the moisture sensor Carefully route and secure the sensor cable so it avoids any moving parts and will not be moved by flowing grain FIGURE 3 Sensor Mounted on Tank Loading Auger Note If you are installing the moisture sensor in the grain tank loading auger the node must be Rev B or greater and software version ...

Страница 28: ...ure carefully 4 Use strap iron or other available materials and any necessary hardware to fabricate a bracket to secure the sensor to the auger enclosure Review the mounting requirements to assist with bracket fabrication The bracket only needs to keep the moisture sensor from moving or vibrating during normal equipment operation Kit P N 117 9000 012 will help with vibration Moisture Sensor Revisi...

Страница 29: ...016 0171 566 Rev C 25 Moisture Sensor Installation FIGURE 4 Moisture Sensor Identification Earlier Revision Sensors Revision Y Sensors Raven 063 0173 629 Raven 063 9000 012 Part Identification Tag ...

Страница 30: ...eader cutout switch The factory rotary switch option allows the operator to make adjustments to the header cutout height on the Raven field computer or display console Connecting a Factory Rotary Switch Cable Note To utilize this switch option use the appropriate adapter cable to tee into the factory installed rotary potentiometer If the feeder house does not have a rotary potentiometer installed ...

Страница 31: ...pter 5 26 SmartYield Pro Installation Manual FIGURE 1 Factory Rotary Potentiometer Examples Note Contact a local Raven dealer for additional assistance with locating the factory header height potentiometer ...

Страница 32: ...r Height Sensor Amp SuperSeal Tee P N 115 9000 016 Used on certain models of Gleaner Massey Ferguson Claas and Challenger Harvesters Header Height Sensor Deutsch DTM Tee P N 115 9000 018 Used on certain models of Case IH Harvesters Header Height Sensor Deutsch DT Tee P N 115 9000 017 Used on certain models of Case IH Harvesters and Aftermarket Sensors Header Height Sensor WeatherPack Female Pins M...

Страница 33: ...s the best range of motion that is free from obstructions Depending on the machine configuration it may be necessary to move the magnet to the alternate mounting hole on the sensor bracket Depending on machine configuration it may be necessary to mount the feeder house magnet directly to the swivel arm instead of using the 90 bracket The sensor shaft can rotate a continuous 360 degrees and the out...

Страница 34: ...016 0171 566 Rev C 29 Header Cutout Switch Installation FIGURE 4 Rotary Sensor Alignment 2 5V 3 5V 4 5V 1 5V 0 5V ...

Страница 35: ...Chapter 5 30 SmartYield Pro Installation Manual ...

Страница 36: ...eration The node features an internal tilt sensor Mount the node with the connectors direction arrow 3 pointing towards the ground When installing the node harness and routing sensor cables ensure that the cables will not interfere with normal equipment operation Make sure that the cables will not be damaged by moving components and secure cables using the supplied cable ties Route cables to avoid...

Страница 37: ...et over before proceeding 3 Secure the magnet to the bracket using a 1 4 nut P N 312 4000 057 Repeat this process to secure the remaining magnets to the node plate 4 Insert a 3 8 bolt P N 311 0054 105 through the magnet side of the mounting plate 5 Thread the bolt through the SmartYield Pro control node P N 063 9000 002 mounting tab and fasten the node to the mounting plate using a 3 8 nut P N 312...

Страница 38: ...force required 2 Tighten the 1 4 bolt to secure the node connector to the node 3 Route the moisture sensor cable connector to the node harness plug labeled Moisture Sensor Secure any excess cable length using the cable ties provided Review the Control Node Installation Recommendations section on page 29 for additional cable routing information 4 Route the yield sensor cable connector to the node h...

Страница 39: ...Chapter 6 32 SmartYield Pro Installation Manual ...

Страница 40: ...nvizio Pro series field computer prior to connecting the SmartYield Pro system 1 Connect the 2 pin Deutsch connector on the yield monitor cable to the connector labeled Switched Power on the field computer cable 2 Connect the 4 pin Deutsch connector on the yield monitor cable to the connector labeled CAN on the field computer cable ...

Страница 41: ...Chapter 7 34 SmartYield Pro Installation Manual FIGURE 1 SmartYield Pro Combine Cable with Envizio Pro Series Cable Connection Diagram D N 054 9000 002 ...

Страница 42: ...y Information 1 Introduction 5 SmartYield Pro Overview 5 J Junction Box Installation 29 Recommendations 29 K Kit Contents Additional Components 7 Optional Components 8 Standard SmartYield Pro Kit Contents 6 M Moisture Sensor Installation 21 Recommendations 21 U Updates 9 Y Yield Sensor Installation 11 Mounting Brackets 14 Paddle Extension Plates 18 Recommendations 11 ...

Страница 43: ...Index 36 SmartYield Pro Installation Manual ...

Отзывы: