Chapter 4
20
Case IH Steiger & New Holland TJ/T90X0 SmarTrax™ Installation Manual
FIGURE 4.
Valve Harness Connected to PVE
5.
Plug the PVES connector from the valve harness into the PVE.
FIGURE 5.
Valve Harness Connected to Flow Switch
6.
Plug the 3-pin TRANSDUCER 1 and TRANSDUCER 2 connectors from the valve harness into the pressure
transducers installed on the flow switch.
Note:
These connections can be plugged into either transducer.
7.
Use plastic cable ties to secure the valve harness to the machine’s frame, hoses, and/or cables, ensuring
the cable is not in contact with moving parts or heat sources.