Manual No. 016-5032-004
11
Hydraulic System Installation
FIGURE 3.
Shuttle Valve Installed in End Cap
3.
Install the tapered end of a shuttle valve (P/N 334-0002-163) into the end cap.
4.
Reinstall the end cap on the steering valve.
Note:
Ensure the O-rings remain seated during installation.
5.
Reinstall and tighten any previously removed mounting bolts, hoses, and/or tubes.
FIGURE 4.
Small End Cap Location
6.
Remove the opposite end cap from the steering valve.
Note:
The second, smaller end cap is not used in the SmarTrax system. Store the end cap in a safe
place for future use in case the SmarTrax system is removed from the machine.
Small
End Cap
Valve Located Behind the Axle
Valve Located by the Cab
Front of Machine
Front of Machine