BIN LEVEL SENSOR INSTALLATION
063-0171-252
Install Bin Level Sensor in spreader bin at location illustrated. Select location in accordance to bin
construction.
Use the mounting plate as a template to mark the location for the holes. Drill and deburr all holes. Route
the sensor cable and secure the mounting plate to the bin wall using U-bolt protectors. Route and connect
the sensor cable connector to the flow cable connector. Secure all cables with plastic cable ties.