![Raven SCS 661 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/raven/scs-661/scs-661_installation-and-service-manual_788844035.webp)
29
4)
DISPLAY SMOOTHING ON/OFF
A)
RATE display will show "diSP". DATA display will show "on".
B)
Depressing
momentarily changes the DATA display between "on" and "oFF". A
value of "on" means smoothing is enabled; a value of "oFF" means smoothing is disabled.
The percent smoothing is determined by the third digit of VALVE CAL value as shown:
Brake Point Digit
(3rd digit) of VALVE CAL 2 1 2 3
0 = 1% + Deadband
5 = 25% + Deadband
1 = 3% + Deadband
6 = 30% + Deadband
2 = 7% + Deadband
7 = 35% + Deadband
3 = 10% + Deadband
8 = 40% + Deadband
4 = 20% + Deadband
9 = 45% + Deadband
Actual rate is displayed if unit does not reach deadband within 10 seconds."oFF" means
RATE displays the actual rate at all times.
C)
Momentarily depress
to advance to FAN RPM.
5)
FAN RPM
A)
RATE display will show "FAn". DATA display will show actual FAN RPM.
B)
Momentarily depress
to advance to FCAL (in liquid application mode) or LEFT
SHAFT FAULT ON/OFF (in granular application mode).
6)
*LEFT SHAFT FAULT ON/OFF
A)
RATE display will show "SHFT". DATA display will show "1oFF".
B)
Depressing
momentarily changes the DATA display between "1oFF" and "1 on". A
value of "1 on" means fault detector is enabled; a value of "1oFF"
means fault detector is disabled.
C)
Momentarily depress
to advance to RIGHT SHAFT FAULT ON/OFF.
7)
*RIGHT SHAFT FAULT ON/OFF
A)
RATE display will show "SHFT". DATA display will show "2oFF".
B)
Depressing
momentarily changes the DATA display between "2oFF" and "2 on". A
value of "2 on" means fault detector is enabled; a value of "2oFF"
means fault detector is disabled.
C)
Momentarily depress
to advance to BIN LEVEL FAULT ON/OFF.
* = GRANULAR APPLICATIONS ONLY
Содержание SCS 661
Страница 1: ...SCS 661 FOR LIQUID AND GRANULAR APPLICATIONS INSTALLATION AND SERVICE MANUAL ...
Страница 2: ...W A R N I N G Disconnect console before jump starting charging battery or welding on equipment ...
Страница 3: ......
Страница 4: ... ...
Страница 6: ...Manual Rev D SCS 661 LIQ 07 02 016 0159 744 ...