System Calibration: Initial Start Up and Calibration Wizard
17
SYSTEM CALIBRATION
RATE SENSOR SETUP
1. Select the Flow Meter Calibration field and enter the calibration value for the flow meter used to monitor the
product flow.
2. Select the units field and use the drop-down options to select the flow meter units.
NOTE:
The flow meter calibration value and units are typically found on a tag or label affixed to the flow
meter. Raven flow meters use a meter cal in pulses per 10 gallons [37.9 L]. Other manufacturers may
use different meter cal units.
3. Enter the Flow Meter Low Limit value. This is the lowest specified reading of the flow meter and can be
obtained from the manufacturer. Raven flow meter low limit values are as follows:
•
RFM 5 - 0.1 GPM (0.4 L/min)
•
RFM 15 - 0.5 GPM (1.9 L/min)
•
RFM 60 - 1.5 GPM (5.7 L/min)
•
RFM 100 - 3 GPM (11.4 L/min)
•
RFM 200 - 15 GPM (56.8 L/min)
4. If available, select the Tank Fill/Level Sensor that is currently installed. If a tank fill flow meter is selected, enter
the meter cal and units for the sensor before proceeding with the calibration.
5. Select the Next button to continue to the Tank Fill Setup page.
TANK FILL SETUP
1. Touch the Tank Capacity field and enter the full volume of the main product tank.
2. Touch the Current Tank Level field and enter the current product volume in the tank.
3. Touch the Low Tank Level field and enter the volume at which the operator should be alerted to a low tank
condition. Enable the Alarm option to allow the system to activate an audible alarm when the Low Tank Level is
reached during field applications.
4. Touch the Max Tank Fill PWM field and enter the maximum duty cycle for the pump to refill the product tank.
5. Touch the Next button to continue to the Rates Setup page.
NOTE:
Additional tank fill setup pages will be displayed for any additional Sidekick Pro ICD products
detected on the system.
RECIRCULATION SETUP
NOTE:
The Recirculation Setup is only displayed when the recirculation feature is unlocked and when
injection is not detected by the RCM - Sprayer ECU.
1. Enable the Boom Recirculation check box if the boom is equipped with recirculation plumbing. Refer to
section on page 39 for additional information regarding the recirculation feature.
2. Enable the Auto Recirculate check box to allow the system to automatically activate the boom recirculation
feature when all boom sections are toggled off.
RATES SETUP
1. Enter Rate and Pressure Preset values that will be used during field applications to quickly change target
application rate or pressures.
NOTE:
Pressure preset values may only be entered if the
AIM Command FLEX™ II NCV system is detected.
Содержание Command FLEX II
Страница 20: ...CHAPTER 2 10 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 30: ...CHAPTER 3 20 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 54: ...CHAPTER 4 44 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 58: ...CHAPTER 5 48 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 68: ...CHAPTER 6 58 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 118: ...APPENDIX A 108 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 122: ...APPENDIX B 112 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 134: ...APPENDIX D 124 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...
Страница 142: ...APPENDIX F 132 RCM Sprayer and AIM Command FLEX II Calibration and Operation Manual ...