![Raven AutoBoom XRT Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/raven/autoboom-xrt/autoboom-xrt_calibration-and-operation-manual_788967066.webp)
C
HAPTER
7
62
AutoBoom XRT Calibration & Operation Manual
VARIABLE DAMPER TEST
This test allows the user to manually apply a control effort to the variable damper system.
1. Select Connectivity Test
2. Enter a Target Effort Percentage
3. Touch the Start button.
NOTE:
Each damper should draw between 2.0 and 2.8 amps when tested at 100%.
FIGURE 18. Variable Damper Test