SETTINGS
CALIBRATIONS
FIGURE 9. Calibrations
AUTO-INDEX OF HEIGHT SENSORS
The Auto-Index of Height Sensors calibration allows the user to verify the number of height sensors and update
the location of the sensors. The user will be prompted to raise the left and right booms. By observing which
sensors had the greatest increase in height at each step, the system learns which sensor is at each location on the
boom.
1. Verify the number of height sensors detected matches the number displayed on the screen.
2. If all sensors are detected, touch the Next button to continue.
FIGURE 10. Height Sensor Setup - Sensor Indexing
3. Unfold the boom and set the booms to level and less than 8 ft. [2.4 m] above ground.