MAINTENANCE

 

📌

Cleaning should be provided by the user 

 

This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this 

wood heater in a manner inconsistent with operating instructions in this manual.

Before any cleaning operation on the stove, implement the following precautions:  

-  switch off the stove and disconnect the power cord with the stove in “Switched OFF” state;  

-  make sure all the parts of the stove are cold; 

-  make sure the ash is completely cooled.  

 

Please read carefully the following instructions to perform proper cleaning. Failure to comply with there instructions may lead 

to malfunctions of the stove.

Before carrying out any maintenance operation on the stove, please take the following precautions:

- Make sure that all the parts of the stove are cold

- Make sure that the ashes are completely extinguished

- Make sure that the general switch is in the zero position (off)

- Make sure that the plug is disconnected from the socket, thus avoiding accidental contacts.

 

📌

Please follow the instructions for cleaning shown below carefully! Failure to observe them may lead to problems in the 

functioning of the stove AND FIRE HAZARD.

Cleaning the surfaces

To clean the surfaces on the painted metal parts, use a wet cloth in water or at the most, water and soap.

 

The use of aggressive detergents or diluents can damage the surfaces of the stove.

Cleaning the FIREX 600

All Ravelli products have a combustion chamber made with FIREX 600, a material based on vermiculite, the result of research and 

development by Ravelli. The main features of FIREX 600 are resistant to heat, its lightness and excellent insulating capacities, im-

proving the combustion and performance of the stove.    

During combustion, FIREX 600 turns white, due to an effect called PYROLYSIS, making the flame clear and shining. If the combus-

tion is regulated in an optimal way, the FIREX 600 interior always remains clean and white.

The condition of FIREX 600 is therefore a thermometer to understand whether the combustion is good or not.

FIREX 600 LIGHT – GOOD COMBUSTION

FIREX 600 DARK – POOR COMBUSTION

Firex 600 does not require special maintenance, it only has to be dusted with a soft brush to remove the ash that is deposited during 

combustion.

Abrasive sponges to clean to most resistant waste should not be used as they could compromise the thickness of the FIREX600 

panel, creating critical points of breakage.

The tube of the vacuum cleaner should not be used in direct contact with FIREX 600.

Wet cloths should not be used to clean FIREX 600.

FIREX 600 is resistant to heat but not to knocks; handle with care if moved.

FIREX 600 may show a slight abrasion after a few hours of functioning, this is perfectly normal as the flame creates microgrooves 

in the panel without compromising it.

The duration of FIREX 600 depends only on how maintenance is carried out.

The pellet stove is a generator of heat with a solid fuel and as such requires servicing by qualified personnel at least once a year at 

the start of the season. This maintenance has the purpose of ascertaining and ensuring the perfect efficiency of all the components.

We recommend you draw up an annual  contract for maintenance of the product with your installer/dealer.

Содержание Vittoria V

Страница 1: ...USE AND MAINTENANCE MANUAL Stoves with Touch Remote Vittoria V Atena V RV 120 Touch...

Страница 2: ...ns could result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Contact local authoriti...

Страница 3: ...from combustible material 15 Standard horizontal installation configurations 16 CONTROLS AND USE 18 Control panel description 18 Radio touch remote control initialization 18 Description of the radio...

Страница 4: ...the Technical service This stove must be used for the purpose for which it has been specifically manufactured Do not use the appliance as an incinerator or in any way other than that for which it was...

Страница 5: ...erials and moved outdoors immediately If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly co...

Страница 6: ...e if cleaning is necessary GENERAL The Stove must only operate in rooms As it is controlled by an electronic board combustion is completely automatic and controlled and the control unit regulates the...

Страница 7: ...not be used They must always be protected from the damp both during transport and in storage Do not place such fuel within the space heater installation clearances or within the space required for cha...

Страница 8: ...blowtorch style with a high quality of incandescent pellets coming out of the grate Correct the pellet air set by reducing the percentage of air from 0 to 5 if not sufficient also increase the percen...

Страница 9: ...0 Touch 0 6 79 25 2 19 2 8 Spare parts Use original spare parts only Do not use any substitute material Do not wait for the components to be worn before replacing them Replace a worn component before...

Страница 10: ...1 8 5 3 Supply V Hz 120 60 120 60 120 60 Hopper capacity Lbs 50 50 50 Efficiency 79 25 79 25 79 25 Smoke temperature min max F 200 415 200 415 200 415 overll heating efficiency is determined using hi...

Страница 11: ...loset or similar conceald space or a floor or ceiling Where passage through a wal or partition of combustible construction is desired the installationshall conform to CAN CSA B365 The stove must be in...

Страница 12: ...rom any forced air intake of any other appliance G Minimum 2 clearance below eaves or overhangs H Minimum 1 clearance horizontally from combustible wall X Must be a minimum of 2 above the roof ridge T...

Страница 13: ...9 0 4 0 3 5 2 2 0 3 9 8 8 2 7 8 7 9 5 6 3 1 8 7 5 3 2 8 3 5 8 0 1 0 7 8 3 4 7 8 9 4 5 3 7 M o d D E S C R I Z I O N E D a t a D i s A p p r M O D I F I C H E 5 4 0 0 0 0 0 0 0 1 M O D _ _ A 1 S C H E...

Страница 14: ...P E R Q U O T E L I N E A R I A N G O L A R I S M U S S I E R A C C O R D I C L A S S E F I N E U N I E N 2 2 7 6 8 1 D O V E N O N I N D I C A T E 1 5 F C H P B e l o t t i v e n e r d 1 4 s e t t e...

Страница 15: ...2 51 2 51 4 102 Back wall to pipe Inch mm 2 75 70 N A 1 25 Side wall to unit L R Inch mm 2 51 2 51 2 51 Side wall to pipe Inch mm 2 75 70 11 280 11 280 Front to unit A Inch mm 40 1000 40 1000 40 1000...

Страница 16: ...stove with pipe attached towards the wall the pipe will go through the wall thimble Do not position the back of the stove closer than 2 51mm from the wall 4 Install listed type PL 45 degree elbow wit...

Страница 17: ...pe If you vent to the furthest wall the vent pipe must maintain a 3 clea rance parallel to the other wall Top View Illustration Notes It is not recommended to ter minate exhaust vent on the prevailing...

Страница 18: ...ges available in the menu Select the desired language with the scroll buttons and confirm your selection with the confirmation button In order to operate correctly the remote control should be interfa...

Страница 19: ...tive cover of the battery on the back of the remote control as shown in Figure A and insert the 3 batteries mini pen style battery AAA 1 5V in the housing of the remote control and observe the poles I...

Страница 20: ...FW VERSION ADJUST LANGUAGE SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE The display is subdivided into three parts 1 It shows the current room temperature measured by the handheld set Mo...

Страница 21: ...LIMA DELTA COMFORT CLIMA DELTA RESTART DELTA SHUTDOWN DELAY SETTINGS SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT THEREFORE NOT PO...

Страница 22: ...dry contact therefore not powered moreover we recommend you use a thermostat with a minimum offset of 3 C if you ntend to use the comfort clima function Description of menu functions Press the key to...

Страница 23: ...om temperature If the type of system designed requires controlling the 3 way valve diagram 1 and 3 it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer CHRON...

Страница 24: ...RE OVER WE RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3 C IF YOU INTEND TO USE THE COMFORT CLIMA FUNCTION Operating phases of the appliance Modulation During the work phase the appliance...

Страница 25: ...W VERSION FW VERSION LANGUAGE LANGUAGE LANGUAGE LANGUAGE ADJUST ADJUST ADJUST ADJUST In Home mode instead of room temperature measured and settable appears the line T ON if the room in which the therm...

Страница 26: ...ey you will confirm of data and switch to the page within SETTINGS menu The stoves equipped with ventilation system can heat the area in which are installed through the heat generated by the window an...

Страница 27: ...mperature set is reached see the dedicated section WAITING START RESTART Switch on is requested but with the stove in cooling phase once this condition is met it restarts automatically IGNITION RESTAR...

Страница 28: ...sists contact the Support Service AL 04 FAN BROKEN Fume exhaust encoder is not working or is connected incorrectly Contact the Support Service No power to fume extractor Contact the Support Service Th...

Страница 29: ...tion to power the gear motor Check the mains voltage AL 15 AUGER TRIAC An internal part of the electronic board that controls the pellet auger is faulty Check the flue is free and clean Possible volta...

Страница 30: ...THERMAL BREAKER below shows the location where to operate to reset the thermal switch with manual reset 1 By pressing the button OK on the display the alarm can be reset 2 Unscrew the protection cap a...

Страница 31: ...r M3 Flue gas fan M4 Front room fan M5 Rear right room fan only for ducted stoves M6 Rear left room fan only for ducted stoves R1 Igniter S1 Flame probe S2 External thermostat S3 Room probe opt G2 Enc...

Страница 32: ...600 a material based on vermiculite the result of research and development by Ravelli The main features of FIREX 600 are resistant to heat its lightness and excellent insulating capacities im proving...

Страница 33: ...the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of the product and or shortcomings on the part of the customer The use of poor quality pellet or any...

Страница 34: ......

Страница 35: ......

Страница 36: ...any variations to the features of its products and to the present manual without notice Aico S p A Headquarter Via Consorzio Agrario 3 25032 Chiari BS Italy Research and Development Centre Viale del c...

Отзывы: