Use and maintenance manual for stoves with touch remote

Pag.28 

Rev.0 05/12/2022

ANOMALY (general)

The stove has detected an anomaly; refer to the troubleshooting 

chapter.

By pressing the confirmation key, the problem is described.

AUTOMATIC CLEANING

SYSTEM ACTIVE

 For models with automatic cleaning system it indicates the 

operating state of the same.

Warning Pop -Up

ANOMALY

DESCRIPTION

SERVICE REQUEST

The threshold value of set work hours has been reached. The symbol displayed 

remains active throughout the work phase. Non-routine maintenance is required 

on the stove.

Alarms (table with reference codes)

TITLE

REASON

 SOLUTION

AL 01 BLACK OUT

No voltage during work phase

Press the switch off key and switch on the stove 

again
If the problem persists, contact the Support Service

AL 02

SMOKE 

PROBE 

FAILURE

The smoke probe is malfunctioning

Contact the Support Service

The smoke probe is disconnected from the 

electronic board

Contact the Support Service

AL 03 OVERTEMP. 

SMOKE

Combustion in the fire pot is not optimal due to 

clogging or obstructions of internal stove ducts 

inside the stove

Switch off the stove, clean the fire pot and the tube 

bundle and adjust the combustion setting the Pellet/

Air values
Contact the Support Service
If the problem persists, contact the Support Service

AL 04 FAN BROKEN

Fume exhaust encoder is not working or is  

connected incorrectly

Contact the Support Service

No power to fume extractor.

Contact the Support Service

The fume extractor is blocked.

Contact the Support Service

AL 05 NO IGNITION

The pellet tank is empty.

Check for the presence of pellets in the container.

Top up, if necessary.

Pellet calibration and suction during switch on 

phase is incorrect.

 Contact the Support Service

The ignition coil is faulty or positioned 

incorrectly

Contact the Support Service

AL 06 NO PELLET

 The pellet tank is empty.

Check for the presence of pellets in the container.

Top up, if necessary.

 The gear motor is not loading pellets.

Empty the tank to see if there are any objects inside 

that may prevent proper operation of the auger.

Not enough pellets loaded

Regulate pellets setting from “SET AIR/PELLETS”
If the problem persists, contact the Support Service

AL 07 THERMAL 

RESET

The manual or automatic reset thermostat 

connected to the hopper has been triggered /

Door, drawer or pellet door remained open

Wait for the stove to cool, reset the thermostat (if 

with manual reset) by pressing the button on the 

back of the stove

Combustion in the fire pot is not optimal due to 

clogging or obstructions of internal stove ducts 

inside the stove

Switch off the stove, clean the fire pot and the tube 

bundle and adjust the combustion setting the Pellet/

Air values
Contact the Support Service

Содержание Vittoria V

Страница 1: ...USE AND MAINTENANCE MANUAL Stoves with Touch Remote Vittoria V Atena V RV 120 Touch...

Страница 2: ...ns could result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Contact local authoriti...

Страница 3: ...from combustible material 15 Standard horizontal installation configurations 16 CONTROLS AND USE 18 Control panel description 18 Radio touch remote control initialization 18 Description of the radio...

Страница 4: ...the Technical service This stove must be used for the purpose for which it has been specifically manufactured Do not use the appliance as an incinerator or in any way other than that for which it was...

Страница 5: ...erials and moved outdoors immediately If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly co...

Страница 6: ...e if cleaning is necessary GENERAL The Stove must only operate in rooms As it is controlled by an electronic board combustion is completely automatic and controlled and the control unit regulates the...

Страница 7: ...not be used They must always be protected from the damp both during transport and in storage Do not place such fuel within the space heater installation clearances or within the space required for cha...

Страница 8: ...blowtorch style with a high quality of incandescent pellets coming out of the grate Correct the pellet air set by reducing the percentage of air from 0 to 5 if not sufficient also increase the percen...

Страница 9: ...0 Touch 0 6 79 25 2 19 2 8 Spare parts Use original spare parts only Do not use any substitute material Do not wait for the components to be worn before replacing them Replace a worn component before...

Страница 10: ...1 8 5 3 Supply V Hz 120 60 120 60 120 60 Hopper capacity Lbs 50 50 50 Efficiency 79 25 79 25 79 25 Smoke temperature min max F 200 415 200 415 200 415 overll heating efficiency is determined using hi...

Страница 11: ...loset or similar conceald space or a floor or ceiling Where passage through a wal or partition of combustible construction is desired the installationshall conform to CAN CSA B365 The stove must be in...

Страница 12: ...rom any forced air intake of any other appliance G Minimum 2 clearance below eaves or overhangs H Minimum 1 clearance horizontally from combustible wall X Must be a minimum of 2 above the roof ridge T...

Страница 13: ...9 0 4 0 3 5 2 2 0 3 9 8 8 2 7 8 7 9 5 6 3 1 8 7 5 3 2 8 3 5 8 0 1 0 7 8 3 4 7 8 9 4 5 3 7 M o d D E S C R I Z I O N E D a t a D i s A p p r M O D I F I C H E 5 4 0 0 0 0 0 0 0 1 M O D _ _ A 1 S C H E...

Страница 14: ...P E R Q U O T E L I N E A R I A N G O L A R I S M U S S I E R A C C O R D I C L A S S E F I N E U N I E N 2 2 7 6 8 1 D O V E N O N I N D I C A T E 1 5 F C H P B e l o t t i v e n e r d 1 4 s e t t e...

Страница 15: ...2 51 2 51 4 102 Back wall to pipe Inch mm 2 75 70 N A 1 25 Side wall to unit L R Inch mm 2 51 2 51 2 51 Side wall to pipe Inch mm 2 75 70 11 280 11 280 Front to unit A Inch mm 40 1000 40 1000 40 1000...

Страница 16: ...stove with pipe attached towards the wall the pipe will go through the wall thimble Do not position the back of the stove closer than 2 51mm from the wall 4 Install listed type PL 45 degree elbow wit...

Страница 17: ...pe If you vent to the furthest wall the vent pipe must maintain a 3 clea rance parallel to the other wall Top View Illustration Notes It is not recommended to ter minate exhaust vent on the prevailing...

Страница 18: ...ges available in the menu Select the desired language with the scroll buttons and confirm your selection with the confirmation button In order to operate correctly the remote control should be interfa...

Страница 19: ...tive cover of the battery on the back of the remote control as shown in Figure A and insert the 3 batteries mini pen style battery AAA 1 5V in the housing of the remote control and observe the poles I...

Страница 20: ...FW VERSION ADJUST LANGUAGE SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE The display is subdivided into three parts 1 It shows the current room temperature measured by the handheld set Mo...

Страница 21: ...LIMA DELTA COMFORT CLIMA DELTA RESTART DELTA SHUTDOWN DELAY SETTINGS SCREW FEEDING CHRONOTHERMOSTAT AIR PELLET SET STOVE STATE CONNECT AN EXTERNAL THERMOSTAT WITH A SIMPLE DRY CONTACT THEREFORE NOT PO...

Страница 22: ...dry contact therefore not powered moreover we recommend you use a thermostat with a minimum offset of 3 C if you ntend to use the comfort clima function Description of menu functions Press the key to...

Страница 23: ...om temperature If the type of system designed requires controlling the 3 way valve diagram 1 and 3 it is necessary to purchase the optional kit from the retailer or the authorized Ravelli dealer CHRON...

Страница 24: ...RE OVER WE RECOMMEND YOU USE A THERMOSTAT WITH A MINIMUM OFFSET OF 3 C IF YOU INTEND TO USE THE COMFORT CLIMA FUNCTION Operating phases of the appliance Modulation During the work phase the appliance...

Страница 25: ...W VERSION FW VERSION LANGUAGE LANGUAGE LANGUAGE LANGUAGE ADJUST ADJUST ADJUST ADJUST In Home mode instead of room temperature measured and settable appears the line T ON if the room in which the therm...

Страница 26: ...ey you will confirm of data and switch to the page within SETTINGS menu The stoves equipped with ventilation system can heat the area in which are installed through the heat generated by the window an...

Страница 27: ...mperature set is reached see the dedicated section WAITING START RESTART Switch on is requested but with the stove in cooling phase once this condition is met it restarts automatically IGNITION RESTAR...

Страница 28: ...sists contact the Support Service AL 04 FAN BROKEN Fume exhaust encoder is not working or is connected incorrectly Contact the Support Service No power to fume extractor Contact the Support Service Th...

Страница 29: ...tion to power the gear motor Check the mains voltage AL 15 AUGER TRIAC An internal part of the electronic board that controls the pellet auger is faulty Check the flue is free and clean Possible volta...

Страница 30: ...THERMAL BREAKER below shows the location where to operate to reset the thermal switch with manual reset 1 By pressing the button OK on the display the alarm can be reset 2 Unscrew the protection cap a...

Страница 31: ...r M3 Flue gas fan M4 Front room fan M5 Rear right room fan only for ducted stoves M6 Rear left room fan only for ducted stoves R1 Igniter S1 Flame probe S2 External thermostat S3 Room probe opt G2 Enc...

Страница 32: ...600 a material based on vermiculite the result of research and development by Ravelli The main features of FIREX 600 are resistant to heat its lightness and excellent insulating capacities im proving...

Страница 33: ...the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of the product and or shortcomings on the part of the customer The use of poor quality pellet or any...

Страница 34: ......

Страница 35: ......

Страница 36: ...any variations to the features of its products and to the present manual without notice Aico S p A Headquarter Via Consorzio Agrario 3 25032 Chiari BS Italy Research and Development Centre Viale del c...

Отзывы: