background image

Installation

General Information

There are two critical components when installing a Sara Insert Wood Pellet Fire: 1) Ensuring the wall cavity is the 

necessary size and 2) ensuring relevant clearances to combustibles are adhered to both inside and outside the 

cavity.  Depending on the circumstances, you may also have to consider the use of a hearth, and the installation 

of the support 

 

 

Cavity.

 

masonry

 

a

 

into

 

installed

 

typically

 

is

 

Sara

 

The

 

 

frame.

Dimensions – Sara Insert & Built-In Heater

Refer to Safety Test 08/1861R1 for all clearances to combustible.

713,5

610

541,5

112

400

78

590

14

527,5

541,5

177,9

72,9

78

476

196,4

589,5

87

51

254,5

154

684

224

517

80

78

587

Содержание Sara

Страница 1: ...et Fire Installation Specifications Safety testing of the Ecoteck Sara Insert Wood Pellet Burning Heater to AS NZS ARS 2918 2001 Flue Emissions 2 R 08 1862 ARS R1 08 1862 ARS 5 0 1185 ARS F App 2918 2001 AS NZS to Testing Kit R1 08 1861 09 2082 09 2078 09 2079 09 2080 ...

Страница 2: ... both inside and outside the cavity Depending on the circumstances you may also have to consider the use of a hearth and the installation of the support Cavity masonry a into installed typically is Sara The frame Dimensions Sara Insert Built In Heater Refer to Safety Test 08 1861R1 for all clearances to combustible 713 5 610 541 5 112 400 78 590 14 527 5 541 5 177 9 72 9 78 476 196 4 589 5 87 51 2...

Страница 3: ... test 05 1185 If installing a floating hearth ensure sufficient clearance is left below the fire to allow for installation of the chosen surround Exterior of Cavity D E J H VENT F B C A G I J VENT Interior of Cavity Creating the Cavity Internal Cavity Dimensions A Width 3 10 0mm min B Depth 590mm min C Height 2090 2320 m m Includes 100mm clearance from rear of flue spigot o s l A g n i w o l l a r o f...

Страница 4: ... Includes 100mm clearance from rear of flue spigot box s w o l l a r o f a m m 0 0 1 l l a w s s e n k c i h t d n a If this measurement is less than 500mm a custom surround will be required Ensure that extra depth required at B is also added to the hearth measurement K Built in fire clearances don t apply in a non combustible cavity The above clearance to combustibles on the flue are only applicable...

Страница 5: ...h all minimum distance to all combustible surfaces Any modifications to the dimensions shown to be verified by consultation with the relevant Building Consent Authority 4 Ensure there is a minimum of 100cm2 ventilation into the cavity this does not need to be from the outside 5 Installers must ensure adequate vermin proof measures are incorporated into the cavity construction if applicable Ensure pr...

Страница 6: ...nclosure 3 Comply with all minimum distance to all combustible surfaces Any modifi cations to the dimensions shown to be verifi ed by consultation with the relevant Building Consent Authority 4 Ensure there is a minimum of 100cm 2 ventilation into the cavity this does not need to be from the outside 5 Installers must ensure adequate vermin proof measures are incorporated into the cavity construction...

Страница 7: ...coach screws Thickness of flooring must be 20mm minimum The flooring shall be fixed to the nearest joist with two 8g x 40 screws per hold down anchor Fixing to Timber Floor Framing Minimum 14g x 60 screws 6 3 diameter or M10 x 90 coach screws These shall be fixed a minimum of 40mm into the centre line of the existing floor joists If screws cannot be installed directly into an existing floor joist slid b...

Страница 8: ... these precautions Pellet e r i F s n o i t u l o S declines all responsibility 1 The fire must be installed on a floor with sufficient carrying capacity If the existing building does not meet this requirement appropriate measures must be taken i e a load distribution plate 2 Sara must be installed on a non combustible surface This surface must protrude a minimum of 150mm from the front of the closed...

Страница 9: ...cavity Depending on the circumstances you may also have to consider the use of a hearth and the installation of a support frame TELEVISION CLEARANCES Television If electrical equipment eg Plasma TV LCD TV or home theatre is to be installed above the wood pellet fire we recommend installing a non combustible mantle below the TV screen or recessing the TV screen into the wall for heat protection 50mm...