background image

Page 7

 

Example

 of

 Cavity

 Design

 - T

op
 V

iew

1.

 

Angle

 section

 for

 support

 fi xed
 to

 timber

 frame/

fl oor
 using

 coach

 screws

 or

 ‘Dynabolts

’ when

 fi xing
 to

 concrete.

2.

 

The
 joint
 for

 fi re

 rated

 board*

 and
 Plasterboard

 located

 over
 frame

 member

 must

 be

 stopped

 to

 manufacture

r’s

 instructions.

  Note:

 W

allpaper

 is

 not
 permitted

 on

 the
 

front

 of

 the
 enclosure.

3.

 

Comply

 with
 all

 minimum

 distance

 to

 all

 combustible

 surfaces.

  Any
 modi

fi cations

 to

 the
 dimensions

 shown

 to

 be

 veri
fi ed

 by

 consultation

 with
 the
 relevant

 Building

 

Consent

 Authorit

y.

4.

 

Ensure

 there

 is

 a

 minimum

 of

 100cm

2

ventilation

 into
 the
 cavity

 (this
 does

 not
 need

 to

 be

 from
 the
 outside).

5.

 

Installers

 must

 ensure

 adequate

 vermin

 proof

 measu

res
 are
 incorporated

 into
 the
 cavity

 construction

 (if

 applicable).

*Ensure

 product

 being

 used

 is

 fi reproof

 rated

 above

 80°C

 eg

 Micore,

 Supalux,

 Eterpan

 or

 similar

NOTES

*

*

210mm

210mm

100mm

Содержание Sara

Страница 1: ...et Fire Installation Specifications Safety testing of the Ecoteck Sara Insert Wood Pellet Burning Heater to AS NZS ARS 2918 2001 Flue Emissions 2 R 08 1862 ARS R1 08 1862 ARS 5 0 1185 ARS F App 2918 2001 AS NZS to Testing Kit R1 08 1861 09 2082 09 2078 09 2079 09 2080 ...

Страница 2: ... both inside and outside the cavity Depending on the circumstances you may also have to consider the use of a hearth and the installation of the support Cavity masonry a into installed typically is Sara The frame Dimensions Sara Insert Built In Heater Refer to Safety Test 08 1861R1 for all clearances to combustible 713 5 610 541 5 112 400 78 590 14 527 5 541 5 177 9 72 9 78 476 196 4 589 5 87 51 2...

Страница 3: ... test 05 1185 If installing a floating hearth ensure sufficient clearance is left below the fire to allow for installation of the chosen surround Exterior of Cavity D E J H VENT F B C A G I J VENT Interior of Cavity Creating the Cavity Internal Cavity Dimensions A Width 3 10 0mm min B Depth 590mm min C Height 2090 2320 m m Includes 100mm clearance from rear of flue spigot o s l A g n i w o l l a r o f...

Страница 4: ... Includes 100mm clearance from rear of flue spigot box s w o l l a r o f a m m 0 0 1 l l a w s s e n k c i h t d n a If this measurement is less than 500mm a custom surround will be required Ensure that extra depth required at B is also added to the hearth measurement K Built in fire clearances don t apply in a non combustible cavity The above clearance to combustibles on the flue are only applicable...

Страница 5: ...h all minimum distance to all combustible surfaces Any modifications to the dimensions shown to be verified by consultation with the relevant Building Consent Authority 4 Ensure there is a minimum of 100cm2 ventilation into the cavity this does not need to be from the outside 5 Installers must ensure adequate vermin proof measures are incorporated into the cavity construction if applicable Ensure pr...

Страница 6: ...nclosure 3 Comply with all minimum distance to all combustible surfaces Any modifi cations to the dimensions shown to be verifi ed by consultation with the relevant Building Consent Authority 4 Ensure there is a minimum of 100cm 2 ventilation into the cavity this does not need to be from the outside 5 Installers must ensure adequate vermin proof measures are incorporated into the cavity construction...

Страница 7: ...coach screws Thickness of flooring must be 20mm minimum The flooring shall be fixed to the nearest joist with two 8g x 40 screws per hold down anchor Fixing to Timber Floor Framing Minimum 14g x 60 screws 6 3 diameter or M10 x 90 coach screws These shall be fixed a minimum of 40mm into the centre line of the existing floor joists If screws cannot be installed directly into an existing floor joist slid b...

Страница 8: ... these precautions Pellet e r i F s n o i t u l o S declines all responsibility 1 The fire must be installed on a floor with sufficient carrying capacity If the existing building does not meet this requirement appropriate measures must be taken i e a load distribution plate 2 Sara must be installed on a non combustible surface This surface must protrude a minimum of 150mm from the front of the closed...

Страница 9: ...cavity Depending on the circumstances you may also have to consider the use of a hearth and the installation of a support frame TELEVISION CLEARANCES Television If electrical equipment eg Plasma TV LCD TV or home theatre is to be installed above the wood pellet fire we recommend installing a non combustible mantle below the TV screen or recessing the TV screen into the wall for heat protection 50mm...

Отзывы: