![Ravelli Sara Скачать руководство пользователя страница 34](http://html2.mh-extra.com/html/ravelli/sara/sara_owners-and-installation-manual_3836960034.webp)
Each 55 Built-in-Heater Flue Kit
(non-Chimney installation) contains:-
y
t
i
t
n
a
u
Q
n
o
i
t
p
i
r
c
s
e
D
o
N
t
r
a
P
1
Galvanised outer liner
ø100mm x 900mm long
4
2
Stainless steel inner liner
ø75mm x 900mm long
4
5
Inner/outer flue liner spacer
2
8
Rain cap 75mm
1
9
Rain cap 100mm
1
This flue kit may be used in new or existing timber
chimneys. The overall height of the flue is 3.6m.
Kit is supplied in a carton.
Heat-resistant
floor protector
Seismic restraint
(to be fitted)
600mm from
roof
penetration
Ravelli Sara & Camino
- new home
(non-Chimney installation)
55
25mm minimum clearance if lined:
75mm minimum clearance if unlined
Note: The Davin 55 Built-in-Heater Flue Kit
for Sara and Camino (non-Chimney) complies
with AS/NZS2918:2001 as per Applied
Research Test Report 05/1185, dated 15
September 2005.
All fires must be installed by a qualified
installer as per the manufacturer’s instruc-
tions and AS/NZS2918:2001.
6c Ceiling thimble ø107mm hole 1
702 Support angle 950mm long
– 40mm x 40mm sides
2
46
Velocity cone
1
Each 55:1 Built-in-Heater Flue Kit
(Chimney installation) contains:-
y
t
i
t
n
a
u
Q
n
o
i
t
p
i
r
c
s
e
D
o
N
t
r
a
P
Galvanised outer liner
ø100mm x 900mm long
4
Stainless steel inner liner
ø75mm x 900mm long
4
5
Inner/outer flue liner spacer
2
8
Rain cap 75mm
1
9
Rain cap 100mm
1
11
Telescopic offset 100mm
(Galvanised) - (2 x 45° bends)
10
Telescopic offset 75mm
(Stainless) - (2 x 45° bends)
Ravelli Sara & Camino
- new home
(Chimney installation)
55:1
This flue kit may be used in new or existing timber
chimneys. The overall height of the flue is 3.6m.
Kit is supplied in a carton.
Note: The Davin 55:1 Built-in-Heater Flue Kit
for Sara and Camino (chimney) complies
with AS/NZS 2918:2001 as per Applied
Research Test Report 05/1185, dated 15
September 2005.
All fires must be installed by a qualified
installer as per the manufacturer’s
instructions and AS/NZS2918:2001.
Heat-resistant
floor protector
Chimney to
be flashed
by builder
25mm minimum clearance if lined:
75mm minimum clearance if unlined
Seismic restraint
(to be fitted)
1
1
6 C
eiling Thimble 1 07mm h
ole
1
ø
702 Support angle 950mm long
– 40mm x 40mm sides
2
46
Velocity cone
1
1
2
Each 56 Insert Flue Kit contains:-
y
t
i
t
n
a
u
Q
n
o
i
t
p
i
r
c
s
e
D
o
N
t
r
a
P
2
Stainless steel inner liner
ø75mm x 900mm long
5
8
Rain cap 75mm
1
19
Flexible flue pipe – stainless
steel ø75mm x 1m
1
839
Casing cover – standard
ø75mm - ø300mm
1
This flue kit may be used in replacement applications
in masonry chimneys. The overall height of the flue is
6.0m. Kit is supplied in two cartons.
Note: The Davin 56 Insert Flue Kit for Ravelli
Applied Research Test Report 05/1185,
dated 15 September 2005.
All fires must be installed by a qualified
installer as per the manufacturer’s
instructions and AS/NZS2918:2001.
Heat-resistant
floor protector
(to be fitted)
56
Ravelli Sara Insert Flue Kit
Sara complies with AS/NZS 2918:2001 as per
Seismic restraint
Stainless steel inner
ø75mm x 0mm long
4
50
1
2
16
Clamp – flexible flue to
stainless flue pipe
46
Velocity cone
1
74
32
Page 10
16. Flueing