11

Page 9

then press and hold [6] for 3 seconds.  The  display 

will show “SCREW STATE”.

2.  Use Button [1] to turn the Auger On “SCREW 1” and 

button [2] to turn it OFF.

3.  Once started auger will run for a couple of minutes 
4.  Remember to turn the screw OFF (SCREW 0) with 

button [2] before exiting, button [3]

5.  Empty the burner pot of any pellets before starting 

the fi re

Also see “6.6 Menu Five - Stove State (Fire Status)” on 

page 10.

6.7 

  Menu Six - Working Hours

The WORKING HOURS Menu shows the total run hours 

done by the fi re. 

To enter this menu, proceed as follows: 

1.  Press Buttons [7] (Menu 01 “Set Clock” will appear). 
2.  Press button [1] twice until you see (Menu 06 

“WORKING HOURS MENU. 

3.  Press [7] to enter this menu . 
4.  Press [3] to return to the main screen.

SCREEN DISPLAY

DESCRIPTION

FINAL CLEANING

The stove is switching off, the cooling phase is not yet completed

LIGHT

The ignition phase has started,the pellets are loaded into fi re pot

WAIT FOR FLAME

The pellet’s are ignited by the hot air passing through the ignition 

candle

FLAME PRESENT

The fl ame is visible in the fi re pot

WORK

The stove has completed the switch ON phase; you can now 

change the power

MODULATION WORK

The set room temperature has been reached

T ON

The room sensor is off or an external thermostat has been 

connected

COOLING/WAITING FOR START

The stove is cooling DOWN. When stove has cooled down it will 

start automatically.

ON/WAITING FOR RESTART

The switch ON phase, when the stove is warm, started. The 

operation is same as phase ON

HOT SMOKE

The max temperature of smokes is reached: to reduce 

temperature, feeding pellets and air draft reduce at POWER 01

OFF

The stove is off

6.8 

Description of Screen Displays

7. Troubleshooting

In the event of a problem with the fi re it will sound an 

alarm and display a fault code and description, see 

“7.1 Explanation of Alarms” on page 12 for more 

information on the cause and what to do.

The fault can be cleared by pressing and holding button 

[3] on the remote. Note which fault is displayed on the 

screen before re-setting the alarm. 
For basic faults follow the steps to resolve the problem

and

 
If

 

below).

 

(see

 

panel

 

electronics

 

the

 

above

 

cap

 

black

 

the

 

under

 

located

 

is

 

This

 

work.

 

will

re 

 

the

 

before

 

re-set

 

manually

 

be

 

to

 

need

 

will

 

device

 

safety

 

The

 

.

 

ALARM”

 

“THERMAL

 

display

 

and

 

device

 

safety

 

a

 

trip

 

will

 

this

 

hot

 

too

 

gets

re 

 

the

 

 

 

agent.

service

/

 

dealer

 

local

 

your

 

 

issues

 

complex

 

more

 

contact

For

 

 

 

re.

 

the

 

restarting

 

try

 

 

 

 

 

 

 

Unscrew

re. 

 

the

 

restarting

 

before

 

trip

 

to

 

device

 

safety

 

this

 

for

 

reason

 

the

 

ascertain

 

you

 

sure

 

 
Make

 

 

alarm.

 

thermostat

 

the

 

reset

 

to

 

button

 

the

 

press

 

and

 

cap

 

protection

 

the

 

Содержание Sara

Страница 1: ...nstallation Manual PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD PELLET FIRE FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH...

Страница 2: ...requires technical programming and individualised air pressure adjustments to ensure it will operate safely and ef ciently and to avoid possible damage to the re or the home Installation of the Sara W...

Страница 3: ...re 8 Menu Descriptions 8 Menu One Setting the Clock 8 Menu Two Set Crono Programmable Thermostat 9 Menu Three Select Language Setting the Language 10 Menu Four View Settings 10 Menu Five Stove State...

Страница 4: ...uel and operation of your stove will directly determine how frequently you will need to clean out the re pot The use of high ash fuels may result in the stove needing to be cleaned daily whereas Pleas...

Страница 5: ...nd after each lighting You must check that the Burn Pot Liner where the combustion takes place is clean and that no waste or residue blocks the holes in order to always guarantee excellent combustion...

Страница 6: ...loading screw 1 Ignition is by means of the resistance 2 which overheats the air from the special intake 5 which on contact with the pellets will allow the development of the ame At this point the exh...

Страница 7: ...e not compliant with the safety instructions Installation that is not compliant with the regulations in force in the country Installation by personnel who are not quali ed or authorized Modi cations a...

Страница 8: ...TING Button 5 on your remote control ROOM TEMPERATURE SETTING see 6 3 1 Modi cations of the room temperature setting on page 9 5 2 Filling the Pellet Hopper Check hopper for foreign objects then empty...

Страница 9: ...ent houses may work better on other settings 6 Switch the power to the re back on the re must be pushed back into its cradle when this is done 7 Press the red button quickly after tuning the power on...

Страница 10: ...01 Monday 02 Tuesday 03 Wednesday 04 Thursday 05 Friday 06 Saturday 07 Sunday OFF Deactivated 5 6 Operating Instructions The heater is completely automated and will self regulate the ignition phase ve...

Страница 11: ...through 10 to set program 2 if required 12 Once you have completed setting up program 2 Press 3 to exit Possible Settings 6 3 1 Modi cations of the room temperature setting The hand held remote that...

Страница 12: ...unit This menu is used when a Service Technician has to understand the parameters set in the machine to nd any modi cations to improve the functioning of the stove 6 6 Menu Five Stove State Fire Statu...

Страница 13: ...d T ON The room sensor is off or an external thermostat has been connected COOLING WAITING FOR START The stove is cooling DOWN When stove has cooled down it will start automatically ON WAITING FOR RES...

Страница 14: ...tricity supply to smoke extractor Contact local Service Technician The smoke extractor is blocked Contact local Service Technician DEPRESSION ALARM The combustion chamber is dirty Follow the cleaning...

Страница 15: ...esh Air Intake Owner Technician Blower Mechanisms Technician Fire exhaust passages Technician Flue system Technician Frequency recommendations given are based on typical re performance and maybe short...

Страница 16: ...of doing this is to vacuum it out Make sure the air intake is clear of ash or debris this can also be vacuumed out to ensure it is clean Place the burn pot back into the re making sure that the burn p...

Страница 17: ...ish patina will form after a few hours A poorly performing re will get brown or black deposits on the glass The glass must be cleaned only when the re is cold using a damp cloth or kitchen paper Somet...

Страница 18: ...rical protection It is very important that the re be thoroughly cleaned and serviced as stated above Exposed metal part may be painted with high temperate paint to prevent rusting over the off season...

Страница 19: ...17 Page 16 9 Maintenance Record E R U T A N G I S T U O D E I R R A C K R O W E T A D...

Страница 20: ...apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product Check with your dealer in advance for any costs to you when arranging a war...

Страница 21: ...let Solution e r i F s approved venting components hearth components or other accessories used in conjunction with the appliance Any part of a pre existing replace system Pellet Ravell i t u l o S i o...

Страница 22: ...re purchase and attach the receipt and any other documents business cards from the retailer that sold you the re Name of Store where Pellet re was purchased e s a h c r u P f o e t a D d i a P t n u...

Страница 23: ...ample of Cavity Design Section View 28 Example of Cavity Design Top View 29 Adjusting the Support Frame 30 Seismic Restraint 30 Fixing to Concrete Floor 30 Fixing to Timber Flooring only 30 Fixing to...

Страница 24: ...al air intake may be required see 5 Creating the Cavity on page 26 for cavity ventilation requirements 6 There must be suf cient circulation of air in the room where the pellet re is installed Never o...

Страница 25: ...i F s n o i t u l o S declines all responsibility 1 The re must be installed on a oor with suf cient carrying capacity If the existing building does not meet this requirement appropriate measures mus...

Страница 26: ...AS NZS 4014 6 standard are recommended Dirty fuel will adversely affect the operation and performance of the unit and will void the warranty The Pellet Fuel Industries PFI has established standards f...

Страница 27: ...t quali ed or authorised Modi cations and repairs that are not authorized by the manufacturer Use of spare parts that are not original Exceptional events If you require further information please cont...

Страница 28: ...est 05 1185 If installing a oating hearth ensure suf cient clearance is left below the re to allow for installation of the chosen surround Exterior of Cavity D E J H VENT F B C A G I J VENT Interior o...

Страница 29: ...0mm min Includes 100mm clearance from rear of ue spigot box s w o l l a r o f a m m 0 0 1 l l a w s s e n k c i h t d n a If this measurement is less than 500mm a custom surround will be required Ens...

Страница 30: ...ith all minimum distance to all combustible surfaces Any modi cations to the dimensions shown to be veri ed by consultation with the relevant Building Consent Authority 4 Ensure there is a minimum of...

Страница 31: ...nclosure 3 Comply with all minimum distance to all combustible surfaces Any modi cations to the dimensions shown to be veri ed by consultation with the relevant Building Consent Authority 4 Ensure the...

Страница 32: ...0 X 90 coach screws Thickness of ooring must be 20mm minimum The ooring shall be xed to the nearest joist with two 8g x 40 screws per hold down anchor 12 Fixing to Timber Floor Framing Minimum 14g x 6...

Страница 33: ...ons and clearance requirements of their electrical appliances to ensure the appliance is suitably located in relation to the wood pellet re t e l l e P e r i F s n o i t u l o S and Ravelli does not g...

Страница 34: ...a Camino new home Chimney installation 55 1 This flue kit may be used in new or existing timber chimneys The overall height of the flue is 3 6m Kit is supplied in a carton Note The Davin 55 1 Built in...

Страница 35: ...by a quali ed technician All operations assume the re is in the default OFF mode press button 3 to achieve this Some operations can also be performed in nal cleaning use caution if the re has been ru...

Страница 36: ...will appear 4 Press 1 or 2 to change to your desired language 5 Press 3 twice to return to the main screen 17 3 3 Menu Four View Settings In this menu you can check the values of the parameters set i...

Страница 37: ...r located on the right hand side of the stove Sometimes due to interference from other electrical household appliances microwave ovens satellite decoders mobile phones the connection between the stove...

Страница 38: ...1 8 Screw power 1 PR06 Sec 2 0 Screw power 2 PR07 Sec 5 2 Screw power 3 PR08 Sec 3 0 Screw power 4 PR09 Sec 3 5 Screw power 5 PR10 Sec Re start threshold PR11 C 80 No pellet threshold PR12 C 50 Off t...

Страница 39: ...Comfort climate PR42 on off OFF Fan 2 speed 1 PR43 V Fan 2 speed 2 PR44 V 140 Fan 2 speed 3 PR45 V 160 Fan 2 speed 4 PR46 V 180 Fan 2 speed 5 PR47 V 210 Draft setting PR48 on off OFF or for version Ai...

Страница 40: ...reen Yellow Green Yellow Green 7 8 11 12 9 10 3 4 Brown Brown Yellow Green Brown 10 9 Brown Blue Yellow Green Black Blue Blue Brown 1 6 6 5 5 6A 5A 1 2 2 6 Encoder Red Black White Black Brown White 7...

Страница 41: ...eration of my Pellet Fire I understand that warranty conditions require an authorised Pellet Fire Solutions Installer to complete the installation Signed Date Installation Details Pellet Fire Model Se...

Отзывы: