background image

Use and maintenance manual for stoves with RDS technology

Pag.4 

Rev.0 05/12/2022

INTRODUCTION

 

📌

Please read this manual carefully. It describes all the phases necessary for perfect functioning of the stove.

 

The regulations on installation and operation in this manual may differ from the regulations in force locally. In this case, the 

indications of the competent local authorities must always be followed. The drawings shown in this manual are indicative 

and not to scale.

Information

The packaging that we have used offers good protection against any damage due to transport. Always check the stove immediately 

after delivery: in the event of any damage, please inform your Ravelli dealer immediately.

Description of use and maintenance manual

With this use and maintenance manual, Ravelli wishes to provide the user with all the information on safety in using the stove, in order 

to avoid damage to persons or things or parts of the stove. Please read this manual carefully before use and any work on the product.

WARNINGS

Ravelli stoves are manufactured taking care even on the individual components in order to protect both the user and the 

installer from any accidents.

The authorized personnel, after any work on the product, should therefore always pay special attention to the electrical 

connections.  

Installation must be performed by authorized personnel, who must give the purchaser a declaration of conformity of the 

appliance, and who will assume all responsibility for the final installation and consequent good functioning of the product 

installed. It is also necessary to take into consideration all the laws and national, regional, provincial and local regulations 

present in the country in which the appliance has been installed. In the event of failure to respect these precautions, Aico 

S.p.A. declines all responsibility.

This instruction manual is an integral part of the product: please make sure that it is always with the stove, including in 

the case of transfer to another owner or user, or transfer to another place. In the case of its damage or loss, please request 

another copy from the Technical service.

This stove must be used for the purpose for which it has been specifically manufactured. Do not use the appliance as an 

incinerator or in any way other than that for which it was designed. All contractual and tort responsibility of the manufacturer 

is excluded for damage caused to persons, animals or things, due to errors of installation, maintenance regulation or 

improper use. No other fuel except the pellets must be used. Do not use liquid fuels.

After having removed the packaging, please make sure that the contents are complete and intact.

All the electrical components that make up the stove must be replaced with original spare parts exclusively from an 

authorized technical assistance centre. 

Maintenance of the stove must be performed at least once a year, planning it in time with the technical assistance centre. 

Do not make any unauthorized modification to the appliance.

For safety reasons, please remember that:

- the stove must not be used by children or disabled people without assistance;

- do not touch the stove when barefoot or when any parts of the body are wet;

- the safety devices or adjustment devices must not be modified without the authorization or instructions of Ravelli.

The stove, especially the external surfaces, reaches very high temperatures when it is in operation; take care when touching 

it to avoid burns.

The stove has been designed to function in any climatic condition; in the event of particularly adverse conditions (wind, freezing), 

safety systems could switch off the stove.

If this occurs, contact the technical assistance and, in any case, do not disable the safety systems.

THANK YOU

Dear Customer,

We would like to thank you and congratulate you on the excellent choice you have made.

With the Ravelli stove, you will see that quality and economy can go hand in hand, offering excellent performances with limited 

consumption and being totally practical. Please find below some suggestions, which we would like to give you, to obtain the most 

from your stove and to fully enjoy all the advantages that it can give you.

Through this, we want to be close to our customers to offer the maximum technical support to all those who use our technology.

Aico S.p.A. thanks you for your confidence

and wishes you happy times in the company 

of your pellet stove.

Содержание Francesca 2015

Страница 1: ...USE AND MAINTENANCE MANUAL Stoves with RDS technology Francesca RV 80 Ceramica Nicole RV 100 Classic Roma...

Страница 2: ...ns could result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Contact local authoriti...

Страница 3: ...tallation only for pellet fireplace insert 17 Minimum opening for masonry and manufactured fireplace only for pellet fireplace insert 20 Standard horizontal installation configurations 21 DESCRIPTION...

Страница 4: ...the Technical service This stove must be used for the purpose for which it has been specifically manufactured Do not use the appliance as an incinerator or in any way other than that for which it was...

Страница 5: ...terials and moved outdoors immediately If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly c...

Страница 6: ...ne if cleaning is necessary GENERAL The Stove must only operate in rooms As it is controlled by an electronic board combustion is completely automatic and controlled and the control unit regulates the...

Страница 7: ...nnot be used They must always be protected from the damp both during transport and in storage Do not place such fuel within the space heater installation clearances or within the space required for ch...

Страница 8: ...n blowtorch style with a high quality of incandescent pellets coming out of the grate Correct the pellet air set by reducing the percentage of air from 0 to 5 if not sufficient also increase the perce...

Страница 9: ...ESIGNER DATA DRWG NR N DISEGNO DATE CAD DRAWNING HANDLING ON CAD SYSTEM ONLY TRATTAM SUPERFICIALE Posizione file di disegno X ECO PROGETTI 00_STUFE ARCHIVIO VALIDI MODELLI SW 1 014 ASS PORTA MONTATA V...

Страница 10: ...1 5 Width Inch 17 32 17 4 20 20 21 7 43 4 Depth Inch 18 46 19 6 19 1 21 9 29 5 Weight Lbs 200 253 270 320 550 Diameter of smoke exit tube Inch 3 14 3 14 3 14 3 14 3 14 Min max hourly consumption of pe...

Страница 11: ...closet or similar conceald space or a floor or ceiling Where passage through a wal or partition of combustible construction is desired the installationshall conform to CAN CSA B365 The stove must be i...

Страница 12: ...from any forced air intake of any other appliance G Minimum 2 clearance below eaves or overhangs H Minimum 1 clearance horizontally from combustible wall X Must be a minimum of 2 above the roof ridge...

Страница 13: ...9 0 4 0 3 5 2 2 0 3 9 8 8 2 7 8 7 9 5 6 3 1 8 7 5 3 2 8 3 5 8 0 1 0 7 8 3 4 7 8 9 4 5 3 7 M o d D E S C R I Z I O N E D a t a D i s A p p r M O D I F I C H E 5 4 0 0 0 0 0 0 0 1 M O D _ _ A 1 S C H E...

Страница 14: ...P E R Q U O T E L I N E A R I A N G O L A R I S M U S S I E R A C C O R D I C L A S S E F I N E U N I E N 2 2 7 6 8 1 D O V E N O N I N D I C A T E 1 5 F C H P B e l o t t i v e n e r d 1 4 s e t t e...

Страница 15: ...ing from floor F Corner from stove Side wall from stove Rear side wall from stove Ceiling from floor Front D Side E Unit of measurement Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm...

Страница 16: ...y be made of combustible material G B E Wall may be made of combustible materials zero clearance Combustib K Combustible floor Minimum distance from combustible material for pellet fireplace insert Ro...

Страница 17: ...tion on the top of the plate to reduce the possibility of condensation This fireplace has not been tested with unvented Gas log set To reduce risk of injury do not install an unvented gas log set into...

Страница 18: ...Use and maintenance manual for stoves with RDS technology Pag 18 Rev 0 05 12 2022 Use only 45 or 30 bends do not use 90 bends...

Страница 19: ...rom the insert to the top of the chimney The chimney liner must be conform to the class 3 require ments of CAN ULC S635 Standard for Lining Systems for ExistingMasonry or Factory Built Chimneys and Ve...

Страница 20: ...over plate non combustible B L vent flex section C The smoke baffle damper and shields may be removed if attached with mechanical fasteners D The metal sides frame members or other structural compo ne...

Страница 21: ...a section of PL pipe until inner pipe liner pushes into the bead of RTV sealer 3 Push the stove with pipe attached towards the wall the pipe will go through the wall thimble Do not position the back o...

Страница 22: ...m clearance between wall and pipe If you vent to the furthest wall the vent pipe must maintain a 3 clea rance parallel to the other wall Top View Illustration Notes It is not recommended to ter minate...

Страница 23: ...e unavoidable inconveniences will disappear after the first hours of operation To reduce your discomfort to a minimum keep the stove on for a few hours on low power and in the beginning do not overloa...

Страница 24: ...he display recommended for use with wall mounted display only With external thermostat Press key 1 from the Home screen to enter the room temperature setting page Set the desired temperature with keys...

Страница 25: ...s still hot i e in FINAL CLEANING the stove will remain in the WAITING RESTART phase for a few minutes after which it will automatically re ignite IGNITION RESTART Modulation During the work phase the...

Страница 26: ...r service during inspection To go to the second screen press key 1 From the first screen it is possible to activate the initial loading of the auger by pressing key 2 The Screw Status value will becom...

Страница 27: ...stoves it is possible to set the temperatures of the individual rooms F front temperature of the stove installation room R Rear single duct room temperature heated by ducting RL and RR Rear Left and R...

Страница 28: ...1 30 Power 3 Room temperature 21 C Activation days Saturday and Sunday Switch on at 9 00 Switch off at 12 00 Power 5 Room temperature Regulated by an external thermostat The Comfort Clima function als...

Страница 29: ...he set value in this case 5 C activated the Comfort Clima function OPERATION The value adjusts the re ignition temperature of the stove EXAMPLE room temperature set at 21 C Comfort Clima value set at...

Страница 30: ...LF CONTROL SYSTEM S C S Enable or disable the function by using key OK Mode SELF CONTROL SYSTEM S C S has been realized allowing the stove to recognize faster an eventual problem just in case you are...

Страница 31: ...the stove appropriately By accessing the menu the adjustment of the draft pellet mixture is displayed To change the percentage use buttons 1 and 2 to switch from adjusting the quantity of pellets to a...

Страница 32: ...To facilitate cooling the stove brings the capacity to a minimum with ventilation at max power level OFF The stove is off ANOMALY general The stove has detected an anomaly refer to the troubleshooting...

Страница 33: ...o read the quantity of inlet air could be disconnected or defect Please contact the local Technical Assistance Centre The device could be dirty and so not read cor rectly Please contact the local Tech...

Страница 34: ...with reset 1 By pressing the button OK on the display the alarm can be reset 2 Unscrew the protection cap and press the button to reset the thermostat alarm 3 Try and repeat lighting after the coolin...

Страница 35: ...ELETTRONICA 24 ottobre 2016 11 24 34 Via Kupfer 25036 Palazzolo S O BRESCIA ITALY MICROINTERRUTTORE MK V11D09 COD 55536 Mod DESCRIZIONE Data Dis Appr MODIFICHE 55536 MOD _ _ A3 SCHEET FORMATO TOLLERA...

Страница 36: ...eased to other parties without written consent any infringement in any way utilized for the manifacture of the component of unit herein illustrated All proprietary right reserved by Society ECOTECK s...

Страница 37: ...tion takes place is clean and that no waste or residue blocks the holes in order to always guarantee excellent combustion of the stove thus avoiding possible overheating which could causes changes in...

Страница 38: ...usted with a soft brush to remove the ash that is deposited during combustion Abrasive sponges to clean to most resistant waste should not be used as they could compromise the thickness of the FIREX60...

Страница 39: ...the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of the product and or shortcomings on the part of the customer The use of poor quality pellet or any...

Страница 40: ...any variations to the features of its products and to the present manual without notice Aico S p A Headquarter Via Consorzio Agrario 3 25032 Chiari BS Italy Research and Development Centre Viale del c...

Отзывы: