Use and maintenance manual for stoves with RDS technology

Pag.33 

Rev.0 05/12/2022

AL

Warning

Reason

Solution

AL 05 NO IGNITION

The pellet tank is empty.

Check if there are pellets inside the tank.

Setting of pellets and of intake during ignition 

phase insufficient.

Contact local Technical Assistance Centre.

The resistance for lighting is defective of not in 

position

Contact local Technical Assistance Centre.

AL 06 NO PELLETS

The pellet tank is empty

Check whether there are pellets in the tank

The ratiomotor does not load pellets.

Empty the tank to check that no objects have 

fallen inside which could prevent the correct func

-

tioning of the auger

No pellet loading

Regulate the pellet setting
If the problem continues, contact the area Techni

-

cal Assistance Centre. 

AL 07

THERMAL 

ALARM WITH 

RESET

The thermostat with manual reset has intervened Reset the thermostat pressing the button on the 

back of the stove

The centrifugal fan is defective

Please contact local Technical Assistance Centre.

Combustion in the fire pot is not optimal

Switch off the stove, clean the fire pot and regu

-

late combustion with the setting of the pellets.
If the problem continues, contact the area Techni

-

cal Assistance Centre.

AL 08 DEPRESSION

The combustion chamber is dirty

Follow the cleaning operations of the stove as per 

the instructions in the booklet

The flue is blocked

Check that the flue is clear and clean

The vacuum switch is malfunctioning

Please contact local Technical Assistance Centre

AL 09 AIR-FLOW 

METER

The device who read the quantity of inlet air could 

be disconnected or defect

Please contact the local Technical Assistance 

Centre

The device could be dirty and so not read cor

-

rectly

Please contact the local Technical Assistance 

Centre

AL 11 LOW FLAME

The pellet tank is empty.

Check whether there are pellets in the tank

Bad setting of pellet and air on ignition in phase

Contact local Technical Assistance Centre

AL 12 FAN RPM

The revolution of smoke fan lowering more the 

15% of speed to fan congestion

Contact local Technical Assistance Centre

AL 13 INSUFFICIENT

FLOW

The door and the ashtray are not correctly closed Check the devices are closed

Bad combustion in the fire pot

Switch off the stove, clean the fire pot, the grid 

and set the combustion through the set pellet/

flow.

Presence of a foreign body inside the air inlet 

pipe

Check for its presence and extract the unwanted 

body

Please contact the local Technical Assistance 

Centre

AL 14

AUGER PHASE

The gear motor is not correctly connected

Please contact the local Technical Assistance 

Centre

AL 15

AUGER TRIAC

The device in the motherboard who gears the 

auger is defect  

Please contact the local Technical Assistance 

Centre

 

📌

AL 09 - AIR-FLOW METER is an alarm that do not block the operation of the stove. In these conditions, the stove goes into 

modulating work, working at fixed extractor revolutions (RDS off). In any case, a periodic visual and acoustic signal indicating 

the type of problem remains active. Please contact the local Technical Assistance Centre

To reset the alarm, keep the OK key pressed for a few seconds. The stove can be restarted manually or automatically (in the case 

of an active chronothermostat or external thermostat) only after resetting the alarm.

Содержание Francesca 2015

Страница 1: ...USE AND MAINTENANCE MANUAL Stoves with RDS technology Francesca RV 80 Ceramica Nicole RV 100 Classic Roma...

Страница 2: ...ns could result in property damage bodily injury or even death Contact local building or fire officials about restrictions and installation inspection requirements in your area Contact local authoriti...

Страница 3: ...tallation only for pellet fireplace insert 17 Minimum opening for masonry and manufactured fireplace only for pellet fireplace insert 20 Standard horizontal installation configurations 21 DESCRIPTION...

Страница 4: ...the Technical service This stove must be used for the purpose for which it has been specifically manufactured Do not use the appliance as an incinerator or in any way other than that for which it was...

Страница 5: ...terials and moved outdoors immediately If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly c...

Страница 6: ...ne if cleaning is necessary GENERAL The Stove must only operate in rooms As it is controlled by an electronic board combustion is completely automatic and controlled and the control unit regulates the...

Страница 7: ...nnot be used They must always be protected from the damp both during transport and in storage Do not place such fuel within the space heater installation clearances or within the space required for ch...

Страница 8: ...n blowtorch style with a high quality of incandescent pellets coming out of the grate Correct the pellet air set by reducing the percentage of air from 0 to 5 if not sufficient also increase the perce...

Страница 9: ...ESIGNER DATA DRWG NR N DISEGNO DATE CAD DRAWNING HANDLING ON CAD SYSTEM ONLY TRATTAM SUPERFICIALE Posizione file di disegno X ECO PROGETTI 00_STUFE ARCHIVIO VALIDI MODELLI SW 1 014 ASS PORTA MONTATA V...

Страница 10: ...1 5 Width Inch 17 32 17 4 20 20 21 7 43 4 Depth Inch 18 46 19 6 19 1 21 9 29 5 Weight Lbs 200 253 270 320 550 Diameter of smoke exit tube Inch 3 14 3 14 3 14 3 14 3 14 Min max hourly consumption of pe...

Страница 11: ...closet or similar conceald space or a floor or ceiling Where passage through a wal or partition of combustible construction is desired the installationshall conform to CAN CSA B365 The stove must be i...

Страница 12: ...from any forced air intake of any other appliance G Minimum 2 clearance below eaves or overhangs H Minimum 1 clearance horizontally from combustible wall X Must be a minimum of 2 above the roof ridge...

Страница 13: ...9 0 4 0 3 5 2 2 0 3 9 8 8 2 7 8 7 9 5 6 3 1 8 7 5 3 2 8 3 5 8 0 1 0 7 8 3 4 7 8 9 4 5 3 7 M o d D E S C R I Z I O N E D a t a D i s A p p r M O D I F I C H E 5 4 0 0 0 0 0 0 0 1 M O D _ _ A 1 S C H E...

Страница 14: ...P E R Q U O T E L I N E A R I A N G O L A R I S M U S S I E R A C C O R D I C L A S S E F I N E U N I E N 2 2 7 6 8 1 D O V E N O N I N D I C A T E 1 5 F C H P B e l o t t i v e n e r d 1 4 s e t t e...

Страница 15: ...ing from floor F Corner from stove Side wall from stove Rear side wall from stove Ceiling from floor Front D Side E Unit of measurement Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm...

Страница 16: ...y be made of combustible material G B E Wall may be made of combustible materials zero clearance Combustib K Combustible floor Minimum distance from combustible material for pellet fireplace insert Ro...

Страница 17: ...tion on the top of the plate to reduce the possibility of condensation This fireplace has not been tested with unvented Gas log set To reduce risk of injury do not install an unvented gas log set into...

Страница 18: ...Use and maintenance manual for stoves with RDS technology Pag 18 Rev 0 05 12 2022 Use only 45 or 30 bends do not use 90 bends...

Страница 19: ...rom the insert to the top of the chimney The chimney liner must be conform to the class 3 require ments of CAN ULC S635 Standard for Lining Systems for ExistingMasonry or Factory Built Chimneys and Ve...

Страница 20: ...over plate non combustible B L vent flex section C The smoke baffle damper and shields may be removed if attached with mechanical fasteners D The metal sides frame members or other structural compo ne...

Страница 21: ...a section of PL pipe until inner pipe liner pushes into the bead of RTV sealer 3 Push the stove with pipe attached towards the wall the pipe will go through the wall thimble Do not position the back o...

Страница 22: ...m clearance between wall and pipe If you vent to the furthest wall the vent pipe must maintain a 3 clea rance parallel to the other wall Top View Illustration Notes It is not recommended to ter minate...

Страница 23: ...e unavoidable inconveniences will disappear after the first hours of operation To reduce your discomfort to a minimum keep the stove on for a few hours on low power and in the beginning do not overloa...

Страница 24: ...he display recommended for use with wall mounted display only With external thermostat Press key 1 from the Home screen to enter the room temperature setting page Set the desired temperature with keys...

Страница 25: ...s still hot i e in FINAL CLEANING the stove will remain in the WAITING RESTART phase for a few minutes after which it will automatically re ignite IGNITION RESTART Modulation During the work phase the...

Страница 26: ...r service during inspection To go to the second screen press key 1 From the first screen it is possible to activate the initial loading of the auger by pressing key 2 The Screw Status value will becom...

Страница 27: ...stoves it is possible to set the temperatures of the individual rooms F front temperature of the stove installation room R Rear single duct room temperature heated by ducting RL and RR Rear Left and R...

Страница 28: ...1 30 Power 3 Room temperature 21 C Activation days Saturday and Sunday Switch on at 9 00 Switch off at 12 00 Power 5 Room temperature Regulated by an external thermostat The Comfort Clima function als...

Страница 29: ...he set value in this case 5 C activated the Comfort Clima function OPERATION The value adjusts the re ignition temperature of the stove EXAMPLE room temperature set at 21 C Comfort Clima value set at...

Страница 30: ...LF CONTROL SYSTEM S C S Enable or disable the function by using key OK Mode SELF CONTROL SYSTEM S C S has been realized allowing the stove to recognize faster an eventual problem just in case you are...

Страница 31: ...the stove appropriately By accessing the menu the adjustment of the draft pellet mixture is displayed To change the percentage use buttons 1 and 2 to switch from adjusting the quantity of pellets to a...

Страница 32: ...To facilitate cooling the stove brings the capacity to a minimum with ventilation at max power level OFF The stove is off ANOMALY general The stove has detected an anomaly refer to the troubleshooting...

Страница 33: ...o read the quantity of inlet air could be disconnected or defect Please contact the local Technical Assistance Centre The device could be dirty and so not read cor rectly Please contact the local Tech...

Страница 34: ...with reset 1 By pressing the button OK on the display the alarm can be reset 2 Unscrew the protection cap and press the button to reset the thermostat alarm 3 Try and repeat lighting after the coolin...

Страница 35: ...ELETTRONICA 24 ottobre 2016 11 24 34 Via Kupfer 25036 Palazzolo S O BRESCIA ITALY MICROINTERRUTTORE MK V11D09 COD 55536 Mod DESCRIZIONE Data Dis Appr MODIFICHE 55536 MOD _ _ A3 SCHEET FORMATO TOLLERA...

Страница 36: ...eased to other parties without written consent any infringement in any way utilized for the manifacture of the component of unit herein illustrated All proprietary right reserved by Society ECOTECK s...

Страница 37: ...tion takes place is clean and that no waste or residue blocks the holes in order to always guarantee excellent combustion of the stove thus avoiding possible overheating which could causes changes in...

Страница 38: ...usted with a soft brush to remove the ash that is deposited during combustion Abrasive sponges to clean to most resistant waste should not be used as they could compromise the thickness of the FIREX60...

Страница 39: ...the Majolica cladding the aesthetic parts any damages caused by unsuitable installation and or use of the product and or shortcomings on the part of the customer The use of poor quality pellet or any...

Страница 40: ...any variations to the features of its products and to the present manual without notice Aico S p A Headquarter Via Consorzio Agrario 3 25032 Chiari BS Italy Research and Development Centre Viale del c...

Отзывы: