Use and maintenance manual for stoves with RDS technology
Pag.26
Rev.0 05/12/2022
The submenus of the USER MENU (the only one accessible for the end user) are the following:
• Menu STOVE STATUS
• Menu SET TEMPER. ROOM
• Menu SET POWER
• Menu CLOCK
• Menu TIMER
• Menu LANGUAGE
• Menu COMFORT CLIMA
• Modalità SILENCE
• Modalità SELF CONTROL SYSTEM
• Menu VIEW SETTINGS
• Menu VIEW WORKING HOURS
• Menu SET DRAUGH/PELLET
Menu STOVE STATUS
In this menu you can check the correct functioning of the most important components of the stove. Here is a list of real data of the
stove useful for service during inspection.
To go to the second screen, press key 1.
From the first screen it is possible to activate the initial loading of the auger by pressing key 2.
The Screw Status value will become 1.
The initial load will stop automatically after a pre-set time, to stop it first press key 2.
Repeat the operation several times until you see the pellet fall into the firepot.
It is possible to do this operation only if the stove is in FINAL CLEANING phase or OFF.
Speed inlet flow
Screw status
Rpm smoke fan
Smokes temperature
RDS current reading RDS (m/s)
RPM current smoke extractor speed (rpm)
Smokes temperature (°C)
Screw status
Set value RDS (m/s)
Cold probe temperature RDS (°C)
Hot probe temperature RDS
(°C)
Electronic board temperature (°C
SET
DF
DR
SK
Screw ON