www.ravas.com
29
Error messages
ERROR MESSAGES INDICATOR 320
Display
Meaning
Out of error mode
Err01
Err02
Err03
Err04
Err06
Err08
Err09
Err10
Err14
CAL-J
Err98
Err99
----
Err_L
OimL
ntEP
SCALL
ESoFt
EConF
Load cell signal is unstable
Overload on full scale
Gross negative. This action is not allowed
Out of zero range
Input signal too high
Calibration out of range (negative)
Calibration out of range (signal too low)
Calibration count 2nd (3rd) point lower than count 1st (2nd)
point
Setpoint value 2 < setpoint value 1. This is not allowed
Legal for trade version: action not allowed
Calibration point must be higher than previous one
Action
only allowed in start-up units
Loadcell signal negative
Pallet truck is out of level (only legal-for-trade version)
Battery of indicator is empty
Action not allowed (only legal for trade version)
Action not allowed (only legal for trade version)
Audit trail no out of range
Wrong combination of firmwares
P96 not set
Automatic
Automatic after removing weight
Automatic
Press any key
Automatic after correcting input
Automatic
Automatic
Automatic
Automatic
When action is intended, remove jumper
JP1 ( attention: after this action a complete
new calibration and stamping of the system
is necessary )
Automatic
Automatic
Lift up the forks from the ground
Put the pallet truck into horizontal position
Charge the battery pack
Automatic
Automatic
Contact RAVAS Service department
Contact
your dealer
Contact your dealer
ERROR MESSAGES RELATED TO INDICATOR 320-BLE ONLY
Display
Meaning
Out of error mode
ErrF1
ErrF2
Er_F1
Er_F2
tiP
SidE
+F1
+F2
LobaF
Problem with transmitter module 1 (no communication)
Problem with transmitter module 2 (no communication)
too few samples for measurement
too few samples for measurement
too large load on the tip of forks
too large load on one fork
battery of transmitter module 1 is empty
battery of transmitter module 2 is empty
Fork batteries are empty (appears after three times
start-up with empty batteries)
Indicator will try to reconnect for 30 sec. Restart
indicator. Restart transmitter module and indicator.
Indicator will try to reconnect for 30 sec. Restart
indicator. Restart transmitter module and indicator.
Wait for improvement of the Bluetooth connection (by
moving the mast to lower position)
Wait for improvement of the Bluetooth connection (by
moving the mast to lower position)
Replace load
Replace load
Replace the Li-ion pack or recgarge
Replace the Li-ion pack or recgarge
charge the fork batteries