www.ravas.com
20
THE TOUCH PANEL
Each key has 2 operational and one entry function
Key
Function level 1
(short key press)
Function level 2
(long key press)
Function level 3
(entry mode)
zero setting
code entry
enter
automatic tare
pre-set tare
decrease the value of
the digit flashing
print weight and add
to the total
check subtotal and
print total
increase the value of
the digit flashing
sampling a piece
weight
enter a piece weight
shift to the next digit
on the left
on/off switch
toggle units
clear entry
IMPORTANT
Operation of a key is not accepted unless the weighing system is stable (and the
“load stable” pointer lights up). This means that the indicator only executes
commands with a stable load.
WARNING
When the weighed load surpasses the pre-set maximum, the display shows:
“ERR02”. In order to prevent damage to the indicator or load cells, the weighing
system must be unloaded immediately.