Faults and possible causes
105
9
Irregular fertiliser feed to
spreading disc
Fertiliser bridging above the
agitator
Remove fertiliser until the
height of the protective grid
on the affected side.
Break up accumulated fer-
tiliser with a wooden stick
through the bars of the pro-
tective grid.
Outlet blocked
See blockages of the mete-
ring openings
Defective agitator
Remove fertiliser until the
height of the protective grid
on the affected side.
Open the metering slide
and break up accumulated
fertiliser with a wooden
stick through the bars of
the protective grid so that
the remaining fertiliser can
run out of the outlet.
Check the functionality of
the agitator drive. See
chapter
.
Spreading discs are fluttering.
Check cap nuts for tight fit
and check threads.
Metering slide does not open
Metering slides do not
move easily.
Check for smooth mo-
vement of the slide, the le-
ver and the joints, and
improve if necessary.
Check the extension
spring.
The reducing plate at the
hose connection of the
plug-in connector is conta-
minated.
Clean the reducing plate at
the hose connection of the
plug-in connector.
The metering slide opens too
slowly.
Clean the restrictor plate.
Replace the 0.7mm restric-
tor plate with a 1.0mm res-
trictor plate. The plate is
located at the hose
connection of the plug-in
connector.
Agitator not working.
The agitator drive is defective.
Check the agitator drive.
See
Fault
Possible cause
Measure
Содержание AXIS-M 30.2
Страница 8: ...Inhaltsverzeichnis VI...
Страница 10: ...Intended use 1 2...
Страница 42: ...Technical data 4 34...
Страница 46: ...Axle load calculation 5 38...
Страница 48: ...Transportation without tractor 6 40...
Страница 110: ...Spreading operation 8 102...
Страница 144: ...Index D...
Страница 146: ......
Страница 147: ......
Страница 148: ......