Chapter 480 

 

 

 

Press buf size

 

=> 

Buffer for sampling rate 

(number of measuring values for the FF calculation) 

Idle buf size

 

=> 

see above at idle measurement

 

Flow factor step

 

=> 

maximum admissible step 

of the FF 

Fill tolerance

 => 

currently not relevant

 

Max valid

 

=> 

currently not relevant

 

+/- LBS Limit

 

=> 

admissible tolerance for AD 

values

  

 

Overload limit (V)

 

=> 

max. signal voltage of the 

overload protection unit

 

Deactivation time (sec)

 

=> 

deactivation delay 

of the agitator in case of overload 

Actuator Min PWM

 

=> 

minimum actuator 

speed

 

Disc Max PWM

 

=> 

limits the maximum speed of 

spreading discs

 

Disc Min PWM

 

=> 

lower speed limit of 

spreading discs

 

 

Idle Limit1 (%)

 

=> 

currently not relevant

 

Idle Limit2 (%)

 

=> 

currently not relevant

 

Disc PWM freq.

 

=> 

PWM for the activation of 

proportional valves

 

SC CRP_XI

 

=> 

calculation of the fertiliser hitting 

point from the coupling point

 

Velocity filter

 

=> 

forward speed filter. For GPS 

signal or very unsteady speeds, the value can be 
increased (max. 12)

 

Содержание AXIS-H 30.1 EMC

Страница 1: ...Rauch Landmaschinenfabrik GmbH Landstr 14 76547 Sinzheim www rauch de english Version 2014_01 AXIS H EMC Service manual AXIS H 30 1 EMC AXIS H 30 1 EMC W AXIS H 50 1 EMC W...

Страница 2: ...4 Electronic system 400 Implement ECU software update 401 Update tool installation 410 AXIS H EMC SW 2 08 00 update 411 AXIS H EMC update as of SW 3 00 00 420 Metering slide calibration 430 Drop point...

Страница 3: ...Diagnosis 610 Voltage supply check 620 Drop point calibration check 630 Metering slide calibration check 640 Weigh cell calibration check 650 LIN actuator check 660 Speed sensor check 670 Pressure se...

Страница 4: ...t diagram 811 Electric circuit diagram part 1 812 Electric circuit diagram part 2 820 Tractor installation cable circuit diagram 2054380 830 Tractor installation cable circuit diagram 2057683 831 Trac...

Страница 5: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 1 Chapter 1 Introduction...

Страница 6: ...shop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 1 Chapter 1 Introduction 110 Preface 120 U...

Страница 7: ...as their disposal and storage are also fundamental requirements Compliance with accident prevention regulations as well as knowledge on the prevention of accidents and hazards are required The operato...

Страница 8: ...r Completely new topics are to be included in new chapters e g 390 If existing instructions or topics are updated or extended new pieces of information are added with a consecutive number e g old chap...

Страница 9: ...XIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 2 Chapter 2 Basic informatio...

Страница 10: ...brik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 2 Chapter 2 Basic information 210 Layout and components 220 Spreader basic...

Страница 11: ...nce of 1 100 mm between the spreading discs the AXIS H 50 1 a distance of 1 400 mm Due to the greater working widths the AXIS H 50 1 features 15 cm motors The AXIS H 30 1 features 11 cm3 motors 1 Impl...

Страница 12: ...relay see figure 5 2056831 3 Hydraulic block complete see chapter Hydraulic system 4 Gearbox please refer to figure 2 a Gearbox left hand side without motor 4087272 b Gearbox right hand side without...

Страница 13: ...s different settings for boundary or section spreading The drop point actuators communicate with the implement ECU via a LIN BUS system The metering slides are activated depending on the application r...

Страница 14: ...asic hopper volume 1200 l 1200 l 2000 l Weigh cell only hopper weight displayed x x Max capacity 3 000 kg 3 000 kg 4 000 kg Hopper size standard unit 240x130 cm 240x130 cm 290x150 cm Basic weight 340...

Страница 15: ...s Spreading disc AXIS H 30 1 EMC AXIS H 30 1 EMC W AXIS H 50 1 EMC W S2 12 18 m X X S4 18 28 m X X X S6 24 36 m X X X S8 30 42 m X X X S10 36 18 m X S12 42 50 m X VxR plus Special coating of the sprea...

Страница 16: ...nition EMC Electronic Mass Flow Control Mass flow control of the fertiliser on the spreading disc by means of torque measurement via pressure sensors Individual control of the slide opening for the le...

Страница 17: ...ding disc 1 pressure sensor located at the return flow for compensating the return flow pressure From the pressure the torque and thus the mass flow can be determined From forward speed application ra...

Страница 18: ...XIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 3 Chapter 3 Mechanical syste...

Страница 19: ...Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 3 Chapter 3 Mechanical system 1 Metering slide basic settings 2 drop point basic settings currently n...

Страница 20: ...etering slide Uneven application rate on the left right hand side Highly unbalanced flow factor on the left and right hand side Auxiliary equipment Lower link pins category II 28mm 1 Basic settings ch...

Страница 21: ...position Correct setting Position 85 In case of deviations release the retention screws of the metering slide scale and relocate the scale in such a way that position 85 is displayed Re tighten the s...

Страница 22: ...XIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 27 10 2014 Chapter 4 Chapter 4 Electronic syste...

Страница 23: ...08 00 update 411 AXIS H EMC update as of SW 3 00 00 420 Metering slide calibration 430 DP actuator initialisation 440 DP actuator calibration 450 Weigh cell calibration 460 Service menu overview and d...

Страница 24: ...le R2058068 RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 4 27 10 2014 Chapter 400 How to find the files for the update w...

Страница 25: ...m Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 4 27 10 2014 Chapter 400 Registration with your dealer login information If you have not obtained your dealer login infor...

Страница 26: ...te with update cable R2058068 RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 3 of 4 27 10 2014 Chapter 400 AXIS Software AXIS H...

Страница 27: ...chinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 4 27 10 2014 Chapter 400 Unpack the zip file and save it in a folder o Here the storage...

Страница 28: ...emory must be available d It might be necessary to deactivate the virus scan Download cable required a Update via USB interface R2058068 b Update via serial interface R2057068 For software update 2 up...

Страница 29: ...n the PC RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 4 27 10 2014 Chapter 401 The installation is completed and an icon...

Страница 30: ...of the update tool Connect the update cable to the desired interface Note If the update cable is connected to the USB port for the first time a driver is installed automatically For this an internet...

Страница 31: ...47 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 4 27 10 2014 Chapter 401 b File loader Open the file loader by double clicking on the icon Path of the implemen...

Страница 32: ...tructions 2 Required accessories PC with USB port Update cable R2058068 If the cable is connected to the PC for the first time a driver is automatically installed For this an internet connection may b...

Страница 33: ...Implement ECU connected to ISO terminal power supply established Note down the settings and calibration data example settings particularly important calibration and settings data Fertiliser settings...

Страница 34: ...EMC W Implement ECU software update as of SW 2 08 00 Rauch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 3 of 16 Update SW 2 08 00 27 08 14 Chapter 410 Service Machine options Scale...

Страница 35: ...Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 4 of 16 Update SW 2 08 00 27 08 14 Chapter 410 4 Implement ECU update 4 1 Open the PEX Loader 4 2 Select the file CAUTION Directory and...

Страница 36: ...pare the software transmission Connect the update cable to the PG and PC update interface 4 4 Start the software transmission Request Switch on the device in the Bootstrap condition Switch on the ISOB...

Страница 37: ...14 Chapter 410 4 5 The end of transmission is indicated Switch off the ISOBUS terminal Disconnect the update cable from the PG update interface at the cable harness Disconnect the ISOBUS device plug a...

Страница 38: ...oftkey settings still need to be loaded 5 1 Prepare the software transmission Re connect the update cable 5 1 1 Open the Teejet File Loader The program establishes a connection to the implement ECU Th...

Страница 39: ...ore the transmission of the language files and the softkset xml softkeys Just select the softkset xml and all language files in the left hand program field and press the right mouse button Delete CAUT...

Страница 40: ...et xml file Select the desired language in the right hand program field The file ending corresponds to the country code example AXIS en The softkset xml file must be transmitted at all times As of sof...

Страница 41: ...iles and the Softkset xml the files are displayed on the left hand side of the LH Loader program Check to ensure that all desired files have been transmitted Close the Teejet File Loader Switch off th...

Страница 42: ...3 00 00 Do not disconnect the connector wait until the spreader is reloaded The spreader is loaded with a new object pool If the spreader is not loaded automatically restart the terminal after approx...

Страница 43: ...ns page 1 RAUCH selection of Rauch or Kuhn logo activated after restart AXIS 50 selection of Axis 50 or Axis 30 Caution Important since there are different parameters for AXIS 50 or AXIS 30 Quantity f...

Страница 44: ...er 410 SC type DIST LENGTH calculation of the GPS switching points via distance and depth of the spreading pattern CCI terminal M ller terminal as of SW 4 xx xx TopCon SC type DIST TIME calculation of...

Страница 45: ...2 08 00 27 08 14 Chapter 410 Control parameters Menu System test Service code 3354 Page 2 Control parameters Control parameters page 1 Efficiency R Efficiency L Re enter the efficiency of the motors C...

Страница 46: ...6 Update SW 2 08 00 27 08 14 Chapter 410 Weigh cells Menu System test Service code 3354 Page 1 Calibration of weighing cells Check the calibration values and overwrite them if applicable If the weighi...

Страница 47: ...s menu Old software only 2 03 00 Initialisation of the drop point actuators If software 2 04 10 was installed before the update the drop point actuators must be reinitialised Chapter 3 30 Drop point i...

Страница 48: ...instructions 2 Required accessories PC with USB port Update cable R2058068 If the cable is connected to the PC for the first time a driver is automatically installed For this an internet connection m...

Страница 49: ...Implement ECU connected to ISO terminal power supply established Note down the settings and calibration data example settings particularly important calibration and settings data Fertiliser settings...

Страница 50: ...W Implement ECU software update as of SW 3 00 00 Rauch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 3 of 16 Update SW 3 00 00 27 08 14 Chapter 411 Service Machine options weighing...

Страница 51: ...uch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 4 of 16 Update SW 3 00 00 27 08 14 Chapter 411 4 Implement ECU update 4 1 Open the PEX Loader 4 2 Select the file Directory and fil...

Страница 52: ...pare the software transmission Connect the update cable to the PG and PC update interface 4 4 Start the software transmission Request Switch on the device in the Bootstrap condition Switch on the ISOB...

Страница 53: ...14 Chapter 411 4 5 The end of transmission is indicated Switch off the ISOBUS terminal Disconnect the update cable from the PG update interface at the cable harness Disconnect the ISOBUS device plug a...

Страница 54: ...oftkey settings still need to be loaded 5 1 Prepare the software transmission Re connect the update cable 5 1 1 Open the Teejet File Loader The program establishes a connection to the implement ECU Th...

Страница 55: ...Before the transmission of the language files and the softkset xml softkeys Just select the softkset xml and all language files in the left hand program field and press the right mouse button Delete...

Страница 56: ...language in the right hand program field The file ending corresponds to the country code example AXIS de The softkset xml file must be transmitted at all times As of software 3 00 00 a key assignment...

Страница 57: ...iles and the Softkset xml the files are displayed on the left hand side of the LH Loader program Check to ensure that all desired files have been transmitted Close the Teejet File Loader Switch off th...

Страница 58: ...00 Do not disconnect the connector wait until the spreader is reloaded The spreader is loaded with a new object pool If the spreader is not loaded automatically restart the terminal after approx 20 s...

Страница 59: ...ns page 1 RAUCH selection of Rauch or Kuhn logo activated after restart AXIS 50 selection of Axis 50 or Axis 30 Caution Important since there are different parameters for AXIS 50 or AXIS 30 Quantity f...

Страница 60: ...SC type DIST LENGTH calculation of the GPS switching points via distance and depth of the spreading pattern CCI terminal M ller terminal as of SW 4 xx xx TopCon SC type DIST TIME calculation of the GP...

Страница 61: ...3 00 00 27 08 14 Chapter 411 Control parameters Menu System test Service code 3354 Page 2 Control parameters Control parameters page 1 Efficiency R Efficiency L Re enter the efficiency of the motors C...

Страница 62: ...5 of 16 Update SW 3 00 00 27 08 14 Chapter 411 Weigh cells Menu System test Service code 3354 Page 1 Calibrate scales Check the calibration values and overwrite them if applicable If the weighing disp...

Страница 63: ...s menu Old software only 2 03 00 Initialisation of the drop point actuators If software 2 04 10 was installed before the update the drop point actuators must be reinitialised Chapter 3 30 Drop point i...

Страница 64: ...D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 5 27 10 2014 Chapter 420 1 Metering slide actuator calibration 2 Checking the calibration 1 Metering slid...

Страница 65: ...s until the scale indicates a position of 0 Then confirm with OK Ensure that the actuator is not at the end stop Otherwise the carrier plate may be shifted into the long holes If the actuator can be m...

Страница 66: ...5 27 10 2014 Chapter 420 Position 1 is not shown on the scale It is slightly under position 0 Check to ensure that the metering slide is closed completely If position 1 is calibrated too far below po...

Страница 67: ...MC W Metering slide actuator calibration RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 5 27 10 2014 Chapter 420 The calib...

Страница 68: ...1 985 250 E mail service rauch de Page 5 of 5 27 10 2014 Chapter 420 2 Checking the calibration Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the metering slide...

Страница 69: ...eeting of the implement ECU and the actuator 1 Preparation Open the cover of the cable duct AXIS H 50 1 1 cable duct AXIS H 30 1 2 cable ducts The connector plugs of the drop point actuators are locat...

Страница 70: ...Initialisation of the drop point actuators Rauch Landmaschinenfabrik GmbH 49 0 7221 985 250 service rauch de Page 2 of 3 AGP Init_de 29 08 2014 Chapter 430 2 Initialisation Figures refer to AXIS H 30...

Страница 71: ...u Delete addresses Disconnect the plugs of the two actuators Then start address claiming Connect the actuator plug for the right hand side The actuator for controlling the right hand side is mounted o...

Страница 72: ...stomer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 4 27 10 2014 Chapter 440 1 Calibration of drop point actuators 2 Checking the calibration 1 Calibration of drop point actuato...

Страница 73: ...firm with OK Ensure that the actuator is not at the end stop Otherwise the setting of the mechanical levers is to be corrected If the actuator can be moved under position 0 as shown in the figure the...

Страница 74: ...e information AXIS H EMC W RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 3 of 4 27 10 2014 Chapter 440 The calibration is comp...

Страница 75: ...mail service rauch de Page 4 of 4 27 10 2014 Chapter 440 2 Checking the calibration Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the drop point settings are act...

Страница 76: ...r 450 1 Recalibration of weigh cells 2 Application of calibration values 3 Checking the calibration Preparation Battery voltage acceptable and or tractor is running Empty hopper Spreader horizontally...

Страница 77: ...is in a horizontal position Confirm empty weight Known quantity Upon confirmation of the empty weight the menu automatically switches over to Known quantity calibration Load the spreader with a known...

Страница 78: ...ange of the implement ECU Figures refer to AXIS H 30 1 EMC with CCI terminal In the calibration data menu the AD values can be read and transmitted CAUTION If weigh cells are replaced recalibration is...

Страница 79: ...is loaded with a weight e g person in the hopper the two diagnosis bars have to be approximately equal The displayed weight should correspond to the actual weight in the hopper observe tare The funct...

Страница 80: ...1 EMC with CCI terminal See chapter Machine options When the spreader leaves the factory all calibration values are stored in the boot menu In the event of calibration problems the factory settings c...

Страница 81: ...hapter Boot menu When an ISO unit is initially loaded in an ISO terminal basic unit information is stored in the terminal in order to speed up loading the next time After an update of the attachment u...

Страница 82: ...014 Chapter 470 As of software 2 05 00 Machine options Settings and explanations In the machine options the spreader is configured After an update the machine options need to be checked After replacem...

Страница 83: ...orrection may compensate the suction effect of the spreading discs At the AXIS this suction effect does not occur due to the design of the spreading disc The value remains at 0 Currently only actuator...

Страница 84: ...e rauch de Page 3 of 3 27 10 2014 Chapter 470 Input of the spreader serial number Specification for the calculation of OPTI POINT Example DIST LENGTH CCI ME SW4 08 01 TopCon DIST TIME CCI JD2600 JD263...

Страница 85: ...hapter 471 As of software 3 00 00 Machine options Settings and explanations In the machine options the spreader is configured After an update the machine options need to be checked After replacement o...

Страница 86: ...ection may compensate the suction effect of the spreading discs At the AXIS this suction effect does not occur due to the design of the spreading disc The value remains at 0 Actuator type Currently on...

Страница 87: ...er serial number SC Type Specification for the calculation of OPTI POINT Example DIST LENGTH CCI ME SW4 08 01 TopCon DIST TIME JD2600 JD2630 Trimble FM1000 YARA AgriTouch Tellus Match AG Leader Integr...

Страница 88: ...0 7221 985 250 E mail service rauch de Page 4 of 4 27 10 2014 Chapter 471 kg level sensor As of an adjustable residual quantity in the hopper the driver receives an alarm message Hopper cover If an el...

Страница 89: ...ameters Settings and explanations With the control parameters the spreader function can be set For this reason any modifications to these parameters are subject to consultation with the technical cust...

Страница 90: ...r EMC factors for the individual spreading discs PWM limit value minimum control rate for proportional valve Hydraulics P Hydraulics I Control parameter for Hydraulics D proportional valve Press toler...

Страница 91: ...Limit admissible tolerance for AD values Overload limit V max signal voltage of the overload protection unit Deactivation time sec deactivation delay of the agitator in case of overload Actuator Min...

Страница 92: ...l parameters Settings and explanations With the control parameters the spreader function can be set For this reason any modifications to these parameters are subject to consultation with the technical...

Страница 93: ...factor EMC factors for the individual spreading discs PWM limit value minimum control rate for proportional valve Hydraulics P Hydraulics I Control parameter for Hydraulics D proportional valve Press...

Страница 94: ...voltage of the overload protection unit Deactivation time sec deactivation delay of the agitator in case of overload Actuator Min PWM minimum actuator speed Disc Max PWM limits the maximum speed of s...

Страница 95: ...Field Handle As of software version 6 11 Rauch no 2057592 This assignment is automatically loaded as default if this joystick type is connected Other joystick types The assignment of the keys must be...

Страница 96: ...chinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 27 10 2014 Chapter 490 Service menu page 2 By pressing Create AUX File the assignment...

Страница 97: ...XIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 04 11 2014 Chapter 5 Chapter 5 Hydraulic system...

Страница 98: ...Chapter 5 Chapter 5 Hydraulic drive 510 Hydraulic block layout 511 Component drawing Hydraulic block layout 520 LS relief at the hydraulic block 530 Proportional valve venting 540 Oil motor drive uni...

Страница 99: ...left hand and right hand side 5 sealing plugs for LS relief see chapter 4 20 6 Pressure sensor 40 bar for return flow 2057358 2057358 2057090 2057890 2 Bottom view 7 Pressure scales oil motor right h...

Страница 100: ...ch de Page 2 of 3 04 11 2014 Chapter 510 4 Left hand view 16 Closure plugs for drilling channels 17 Connection P oil motor right hand side 15L 18 Connection P oil motor left hand side 15L 5 Right hand...

Страница 101: ...djustment screw for load sensing constant current conversion 4 Sealing plugs for measurement connection 6 Pressure sensor 40bar 7 Pressure scales oil motor right hand side 8 Pressure scales oil motor...

Страница 102: ...s hydraulic system may lead to speed variations of the spreading discs Solution For hydraulic blocks delivered as of calendar week 48 2011 a relief can be created in the hydraulics block by means of s...

Страница 103: ...activation of the control units or the automatic steering increases the stand by pressure to up to 50 bar o Size of the free return flow of the tractor is sufficient return flow filter is clean o LS...

Страница 104: ...behind the spreader or disassemble the spreading discs Preparation Drive via Load Sensing Start the tractor slightly increase the engine RPM of the tractor Drive via constant flow Start the tractor s...

Страница 105: ...When placing an order please ensure that the correct unit and the correct side are ordered 1 Overview of components Type AXIS H 30 1 EMC W AXIS H 50 1 EMC W Side in direction of travel left right lef...

Страница 106: ...or disconnect the connector at the cable harness CAUTION During disassembly of the disc speed sensor gear oil may escape from the gearbox Disconnect the return tube and the pressure tube It may be nec...

Страница 107: ...AUTION Please observe the direction of rotation of the oil motors There are left and right gear units Reattach the gearbox to the crossbeam Reconnect the hydraulic lines Prior to the installation of t...

Страница 108: ...wear and for fertiliser deposits Otherwise the results may be incorrect Compare the quantity spread according to the trip counter with the quantity displayed by the scales Check whether the spreader i...

Страница 109: ...level is to be checked regularly Check for oily deposits at the gearbox Prior to the oil change Working under the spreader Secure the spreader against accidental falling Take precautions against esca...

Страница 110: ...inzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 04 11 2014 Chapter 550 Fill in the oil pump nozzle Oil type approx 0 3 l SAE 75W 90 Bottom edge of the sensor bor...

Страница 111: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 6 Chapter 6 Test Diagnosis...

Страница 112: ...250 E mail service rauch de Page 2 of 2 29 10 2014 Chapter 6 Chapter 6 Test Diagnosis 610 Voltage supply check 620 Drop point calibration check 630 Metering slide calibration check 640 Weigh cell cali...

Страница 113: ...47 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 610 Figures refer to AXIS H 30 1 EMC with CCI terminal Here the power supply of the implem...

Страница 114: ...ine 49 0 7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 620 Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the drop point settings are activa...

Страница 115: ...ine 49 0 7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 630 Figures refer to AXIS H 30 1 EMC with CCI terminal By means of the Start Stop button the metering slide settings are ac...

Страница 116: ...weight can be filled in for testing Please ensure that the weight is positioned in the centre of the hopper If the spreader is loaded with a weight e g person in the hopper the two diagnosis bars have...

Страница 117: ...via a bus connection The following functions are controlled via LIN actuators Drop point Hopper cover AXMAT TELIMAT AXIS M 50 1W only Figures refer to AXIS H 30 1 EMC with CCI terminal With Start sel...

Страница 118: ...apter 660 Working under the spreader Switch off the tractor Secure the spreader against falling 2 Visual inspection The disc speed sensor is located at the front of the angular gearbox The sensor is e...

Страница 119: ...eading disc is rotated pulses must be displayed on the right hand side Test with running spreader Ensure that no one is in the danger area of the machine Tractor running active oil supply to the tract...

Страница 120: ...pressure sensors Return sensor Flow factor increase or decrease on both sides Idle measurement does not start Sensor left right Flow factor increase or decrease on one side Idle measurement does not s...

Страница 121: ...nit off Load Sensing Tractor off In idle state the AD values have a value of approx 195 Example for a sensor with short circuit AD 1023 Example for a sensor with interruption AD 0001 2 Measurement Hyd...

Страница 122: ...values on the left and right side should be approximately equal Potential causes for unbalanced AD values Defective or contaminated pressure sensor High wear at the spreading discs Incorrect spreadin...

Страница 123: ...7221 985 250 E mail service rauch de Page 1 of 1 29 10 2014 Chapter 680 In case of problems with the ISOBUS communication a hidden menu can be accessed to read out important data for programmers on i...

Страница 124: ...AXIS H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 7 Chapter 7 Troubleshooting...

Страница 125: ...ettings 710 Alarm message overview 720 Idle measurement abortion idle measurement is not fully completed 721 As of SW 3 00 00 Idle measurement is not completed 730 Flow factor increase on both sides 7...

Страница 126: ...g opening is reached The set application rate appl rate exceeds the maximum metering opening 3 Flow factor lies outside acceptable limits The flow factor must lie within a range between 0 40 and 1 90...

Страница 127: ...onnector 21 Spreader overloaded For weighing spreader only Mineral fertiliser spreader is overstrained Too much fertiliser in the hopper 22 Unknown status Function Stop Communication problem at Termin...

Страница 128: ...49 0 7221 985 250 E mail service rauch de Page 3 of 3 29 10 2014 Chapter 710 34 Empty run border spread no empty run measurement can be executed spreading discs are rotating with reduced speed Empty r...

Страница 129: ...epeatedly Disc speed is not achieved Spreading disc speed fluctuating Metering slide fluctuating buzzing actuators Idle position 1 of the metering slides is not reached or the actuator hits the end st...

Страница 130: ...ent can be performed The temperature of the tractor hydraulic oil is too low the pressure differences are too high The spreading disc type in the fertiliser settings complies with the assembled spread...

Страница 131: ...immediately on both sides when spreading begins Error message Flow factor outside acceptable limits Fertiliser flow factor outside of the controllable range compare fertiliser chart Switch to manual m...

Страница 132: ...f the controllable range compare fertiliser chart Switch to manual mode Return pressure sensor defective Pressure sensor return check in the Test Diagnosis menu see chapter 5 Metering slide actuators...

Страница 133: ...in the Test Diagnosis menu see chapter 5 Clogging in the outlet e g due to fertiliser remaining in the hopper for a prolonged period Low moist fertiliser quality Empty the hopper and correct the clog...

Страница 134: ...pulse sensor Forward speed via tractor bus system Recommendation Set the filter to 6 8 Disc speed fluctuation Disc speed is not achieved For one idle measurement the speed fluctuation must not exceed...

Страница 135: ...disc Sufficient tractor power supply voltage drop if the electric agitator is activated Sluggish agitator drive Corroded machine cable harness 2 The spreading disc speed falls or starts to fluctuate...

Страница 136: ...t must be possible to rotate the piston rod manually Check the housing and cable inlet for damage Check the machine cable Check the connectors for humidity and corrosion Check the PG connection update...

Страница 137: ...splay voltage CCI terminal with the tractor installation cable R2057683 Connect a bus terminator to CAN OUT The bus terminator at the CPC plug of the cable harness must be connected Tractor installati...

Страница 138: ...EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 8 Chapter 8 Circuit diagrams Elec...

Страница 139: ...version Connection of various CCI terminal 802 Connection of various terminals to tractor ISO systems 810 Overall electric circuit diagram 811 Electric circuit diagram part 1 812 Electric circuit diag...

Страница 140: ...stomer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 6 29 10 2014 Chapter 800 1 AXIS H EMC with CCI Tractor installation cable 2054380 or or 2057686 Kit 4087369 2057686 2057688 2...

Страница 141: ...7221 985 250 E mail service rauch de Page 2 of 6 29 10 2014 Chapter 800 2 AXIS M ISOBUS with CCI Tractor installation cable 2054380 Kit 4087369 Cable 1st Generation Replaced by Kit 4087369 or 2057686...

Страница 142: ...221 985 250 E mail service rauch de Page 3 of 6 29 10 2014 Chapter 800 3 AXERA H EMC with QUANTRON P Tractor installation cable 2054380 2054234 198 273 For connection to the integrated bus system of F...

Страница 143: ...e hotline 49 0 7221 985 250 E mail service rauch de Page 4 of 6 29 10 2014 Chapter 800 4 AXIS H EMC QUANTRON I Comfort terminal BT top Tractor installation cable 2054380 2057687 2057045 Cable 1st Gene...

Страница 144: ...E mail service rauch de Page 5 of 6 29 10 2014 Chapter 800 5 AXIS M ISOBUS QUANTRON I Comfort terminal BT top Tractor installation cable 2054380 2057045 Cable 1st Generation Replaced by Kit 4120323 A...

Страница 145: ...7221 985 250 E mail service rauch de Page 6 of 6 29 10 2014 Chapter 800 6 AGT QUANTRON I Comfort terminal BT top Tractor installation cable 2054380 2057045 Cable 1st Generation Replaced by Kit 4120323...

Страница 146: ...250 E mail service rauch de Page 1 of 3 29 10 2014 Chapter 801 1 CCI applies for all ISOBUS devices Cable harness 2057683 Bus termination 2057684 at CAN 1 OUT Bus connection 2057684 The bus terminati...

Страница 147: ...service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 3 29 10 2014 Chapter 801 2 QUANTRON I Comfort Terminal BasicTerminal Top Cable harness 2057683 2057687 2057685 15 Cable for ignitio...

Страница 148: ...0 7221 985 250 E mail service rauch de Page 3 of 3 29 10 2014 Chapter 801 3 AXERA H EMC with QUANTRON P Cable harness 2057683 2057685 Cable for ignition probing Via this cable the power relays are co...

Страница 149: ...rauch de Page 1 of 3 29 10 2014 Chapter 802 1 CCI In some cases the tractor bus systems still need to be configured and the CCI needs to be registered as secondary terminal Can settings uncheck prior...

Страница 150: ...29 10 2014 Chapter 802 2 QUANTRON I Comfort terminal BT top In some cases the tractor bus systems still need to be configured and the M ller terminal needs to be registered as secondary terminal as of...

Страница 151: ...connectors however it runs as an LBS system LBS Landwirtschaftliches Bus System preceded ISOBUS The connection can only be established to Fendt tractors or tractors whose bus system can be completely...

Страница 152: ...ght Agitator signal Prop Valve left Pressure sensor right Pressure sensor return Pressure sensor left Connection Update Agitator power ISOBUS plug Slide left Slide right Hopper sensor left Hopper sens...

Страница 153: ...is H EMC Kabelbaum mit ISO Stecker M I Prop valve Right Agitator signal Prop valve Left Pressure sensor Right Pressure sensor Return Pressure sensor Left Connection Update Agitator Power ISOBUS Plug V...

Страница 154: ...plan Axis H EMC Kabelbaum Aktuatoren Slide left Slide right Hopper sensor left Hopper sensor right Weigh cell left Weigh cell right AGP left AGP right Disc sensor left Disc sensor right SL SR LL LR WL...

Страница 155: ...0 1 2 3 4 5 6 7 5 8 9 8 3 9 4 3 6 A B A B A B B B A B B A B C D 9 3 E A 7 A 7 A F G A F G A G H 6 A H7 A I H5 75 A G H6 0 A J F K A I G 7 L IJ F M CFD B 5 E E...

Страница 156: ...1 3 71 2 7 738 738 5 9 6 7 6 2 3 0 2 23 7 9 2 8 3 8 7 2 9 6 7 2 2 37 8 5 3 5 9 5 2 8 9 8 1 2 6 6 7 5 6 3 2 2 2 2 2 2 7 37 8 2 2 2 8 5 9 6 7 2 1 2 1 1 33 8 6 3 33 23 23 23 23 4 87 2 33 33 76 17 23 2 3...

Страница 157: ...6 33A 0 33A 33A 33A 33A 25 33A 0 B B C B D 2 9 33A 33A 33A 25 33A C D 2 3 3 7 C D 2 7 33 4 2 2 2 4 4 4 Originaldateiname 83233162_0 pdf Artikelnummer Index Status Eingangsdatum Bearbeiter ergaenzende...

Страница 158: ...5 2 0 2 5 2 7 7 5 2 5 7 5 8 8 52 7 4 8 5 6 7 4 4 2 4 5 7 752 7 7 2 75 2 5 7 2 4 5 2 5 2 5 4 52 6 7 4 3 4 6 75 7 2 2 9 9 4 Originaldateiname 83233133_2 pdf Artikelnummer Index Status Eingangsdatum Bear...

Страница 159: ...B A0 A A 0 A B A C A B D 7 52 C B D 7 52 5 5 55 C B D 7 52 5 25 9 9 75 2 7 75 9 9 0 0 1 2 3 3 0 1 2 0 4 3 0 2 0 4 5 6789 0 4 5 0 4 5 47 0 0 678 0 1 0 1 6789 0 0 4 678 0 0 2 1 8 0 0 8 0 0 1 847 0 0 1...

Страница 160: ...eschaltet NC 2 Notaus_Eingang W stand 5 CAN1 L W stand 7 CAN1 H NC 1 U B Br cke 4 Notaus_Versorgung NC 6 GND NC 8 Schirm Beschreibung Ader rot U B _geschaltet 5300 50 mm Beschreibung Dieses Kabel dien...

Страница 161: ...enfabrik GmbH D 76547 Sinzheim Kundendienst Hotline 49 0 7221 985 250 e mail service rauch de Seite 1 von 1 03 11 2014 agitator R3087356 i 7 1 agitator R2058051 i 10 1 since Mai 2014 Pin connection Su...

Страница 162: ...EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 29 10 2014 Chapter 9 Chapter 9 Circuit diagrams Hydr...

Страница 163: ...GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 29 10 2014 Chapter 9 Chapter 9 Hydraulic circuit diagrams 910 Hydraulic block circuit diagram 911 H...

Страница 164: ...ew for LS KS conversion 4 Sealing plugs for measurement connection 6 Pressure sensor 40bar 7 Pressure scales oil motor right hand side 8 Pressure scales oil motor left hand side 9 Connection free retu...

Страница 165: ...H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 05 11 2014 Chapter 10 Chapter 10 Technical Informa...

Страница 166: ...H EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 05 11 2014 Chapter 10 Chapter 10 Technical Informa...

Страница 167: ...a standard beginning September 2014 The new cable harness order no 2058201 is installed as a standard as of May 2014 The new software V 3 00 00 with modified start up behaviour of the agitator motor w...

Страница 168: ...n 3 01 00 is available for download in the RAUCH portal for business partners Joystick operation Operation by means of the AUX N joystick MFG 4 by WTK Elektronik is released The joystick is also avail...

Страница 169: ...in the working screen figure 5 Figure 5 Adaptive idle measurement The time between 2 idle measurements is now calculated according to the type and speed of the spreading discs considerably reducing th...

Страница 170: ...Figure 7 Drop Point at deactivated sections If all sections of one side are deactivated the larger DP is now automatically set to reduce the reaction time at reactivation Figure 8 Electrical hopper c...

Страница 171: ...is The LINBUS diagnosis now displays all devices on one page The automatic check is started by Start self test Error code 0 ok Error code 2 blockage Error code 4 overload Figure 13 Available languages...

Страница 172: ...levant machine In the past these parameters had to be requested by telephone from the RAUCH customer service Improvement Since 10 10 2014 AXIS 39602 each transmission is equipped with a label Example...

Страница 173: ...EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 1 of 2 05 11 2014 Chapter 11 Chapter 11 Terminal Compatibili...

Страница 174: ...EMC Workshop manual RAUCH Landmaschinenfabrik GmbH D 76547 Sinzheim Customer service hotline 49 0 7221 985 250 E mail service rauch de Page 2 of 2 05 11 2014 Chapter 11 Chapter 11 Terminal compatibili...

Страница 175: ...Tasten Ja Ja Ja Nein Ja Nein Kverneland Tellus ISOMatch 1 8 Ja 2x6 Tasten Ja Ja Ja aber nur ein Abstand eingebbar Ja Nein Nein Fendt Varioterminal 7 Ja 2x6 Tasten Nein Nein Nein Nein Nein Nein Fendt V...

Отзывы: