AXIS-H EMC
Flow factor (FF) decrease or increase on
one side
Highly unbalanced flow factor
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: [email protected]
Page
1
of
1
29.10.2014
Chapter 750
•
The flow factor decreases or increases immediately or during spreading on one side
•
Error message: Flow factor outside acceptable limits
•
The flow factor deviates considerably on one side
Left or right pressure sensor defective
Pressure sensor check in the
Test/Diagnosis menu
=> see chapter 5
Metering slide actuator sluggish or
defective
Metering slide actuator check in the
Test/Diagnosis menu
=> see chapter 5
Clogging in the outlet, e.g. due to
fertiliser remaining in the hopper for a
prolonged period
Low, moist fertiliser quality
Empty the hopper and correct the
clogging
CAUTION! Disconnect the machine
plug at the outlet to stop the agitator
prior to any cleaning attempts!
Check the metering slide calibration
+ Check the spreading vanes for wear
+ Check the spreading discs for
distortions
+ Check the spreading discs for
fertiliser deposits
Test/Diagnosis menu
=> see chapter 5
- Move to slider test points
If required: Slide recalibration
=> see
chapter 3
+ Spreading vanes with holes or
considerable signs of wear may impair
EMC control
+ Replace distorted spreading discs
+ Remove deposits
Check the metering slide basic
settings
Check the metering slide basic settings
=> see chapter 2