Part IV Disassembly and Maintenance
41
e) Check the ignition coil
(Primary side)
Make contact between tester terminal and wire terminal and coil core, to measure the resistance
value of coil primary.
The resistance of primary coil: 1.0-1.5 Ω (recommended value)
(Secondary side)
Remove the cap of spark plug, to connect one end of the tester to HV harness, and make contact
between the other end and coil core, to measure resistance value on the secondary side of the
coil.
The resistance value of secondary coil: 5-7 kΩ
Make the tester touch both ends of the spark plug cap to measure the resistance value of the
spark plug cap.
Resistance value: 5kΩ±5%/10kΩ±5% (recommended)