![Rational SelfCooking Center Скачать руководство пользователя страница 58](http://html2.mh-extra.com/html/rational/selfcooking-center/selfcooking-center_operating-manual_3802747058.webp)
- 54 -
Guide the hose into the steam inlet up to the
mark shown on the hose. Fasten the hose to the
left grid shelf with the wire hook.
Note:
The allocation of marking to unit size is
described in the descaler pump instructions.
Replace left grid shelf to secure the descaler
hose.
Introduce the hose into the canister with the
descaling fl uid.
Place the canister in the cabinet.
Use the appliance manufacturer’s hand
pump to very slowly fi ll with the amount of
descaling fl uid shown on the display.
Caution!
• Descaling fl uid reacts with lime and can
foam over.
As soon as the indicated amount of descaler
has been fi lled, please confi rm input.
Remove the descaling accessories (hand
pump and canister) from the cabinet.
Caution!
•
Residual quantities of descaling fl uid
may be present in the hoses.
Rinse cabinet and descaling accessories
thoroughly with hand shower.
Insert air baffl e and left grid shelf correctly
into the cabinet and lock properly.
Close the cooking cabinet door – Descaling
process starts automatically.
Steam generator descaling
6
7
8
9
10
fill 5 liter descaler
11
stop filling?
12
13
14
close door
15