![Rational SelfCooking Center Скачать руководство пользователя страница 57](http://html2.mh-extra.com/html/rational/selfcooking-center/selfcooking-center_operating-manual_3802747057.webp)
- 53 -
Descaling
Warning!
• The process described involves working
with an aggressive chemical fl uid – danger
of corrosive burns!
• To prevent damage to materials and
health it is vital that you use:
protective clothing
safety goggles
protective gloves
face mask
the manufacturer’s descaler hand pump
• Thoroughly rinse descaling fl uid spills with
water immediately.
• After descaling rinse descaler pump and
hoses thoroughly with water.
• Use only the descaler made by the
appliance manufacturer.
• Follow descaler pump instructions and
safety instructions.
You will need:
Electric descaler pump – Article no.: 60.70.409
Descaler, 10 litre canister – Article no.: 6006. 0110
Deselect operating mode
Follow user prompt
Note:
If the cabinet temperature exceeds 40 °C,
the display will show the message
Please cool the cabinet with „Cool Down“.
Once your unit has cooled down you can continue
descaling
Wait until the steam generator has cooled down.
Remove left grid shelf and air baffl e.
Steam generator descaling
1
2
3
4
descale
unit to hot
open door
descale
close door
wait cool
steam generator
5