6 | Electrical connection
80.06.231_iVarioProL-iVarioProXL_IM_en-GB
43 / 72
n
Calculate the conductor cross section according to the length and quality
of the power cable used.
3 NAC 400 V
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
27
40
40
6
iVario Pro XL
41
59
63
10
3 NAC 400 V
Balanced power
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
21
30
32
4
iVario Pro XL
34
50
50
10
3 NAC 415 V
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
29
41
50
10
iVario Pro XL
44
61
63
10
3 AC 200 V
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
26
74
80
16
iVario Pro XL
38
111
125
35
3 AC 208 V
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
23
64
70
16
iVario Pro XL
34
96
100
25
3 AC 220 V
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
25
66
80
16
iVario Pro XL
38
100
100
25
3 AC 230 V
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
27
69
80
16
iVario Pro XL
41
103
125
35
3 AC 240 V
Power kW
Amp draw A
Fuse A
Conductor cross-sec-
tion mm²
iVario Pro L
22
53
60
10
iVario Pro XL
37
88
100
25