- 15 -
V06
GB
Service parts / trouble shooting
Service parts:
Part number description
60.30.139
Leg for stand
TC for 6X1/1GN and 10X1/1GN units
2x 60.30.255 Door gasket
TC for 6X2/1GN and 10X2/1GN units
1x 60.30.255 Gasket for door left side
1x 60.30.258 Gasket for door right side
42.00.024
operator pcb
42.00.025
power pcb
40.02.146
heating element
40.01.561
PT 500 resistance
60.30.238
Double ball catch with
counter part
2610.400279
Door handle
3038.0313
Connection box
3038.0315
Lid of connection box
4007.0630
Cable gland M32
4007.0640
Nut for cable gland M32
60.30.292
Door holding bracket left
60.30.293
Door holding bracket right
60.30.259
Bushing bottom
40.02.756
Safety thermostat
3014.0325
Klixon (only USA)
Trouble shooting
Failure codes:
E1: Will be indicated, if temperature inside cabinet
is below -10°C (14°F)
E2: Will be indicated, if temperature inside cabinet
is above 114°C (237°F)
Possible reason
Thermo sensor PT 500 defect
- No heating
Possible reason:
Safety temperature limiter has tripped.
For testing of STL remove center bar of the TC
and afterwards the heating elements with holder.
STL can be found in the connection box of heat-
ing elements.
Содержание 60.30.007
Страница 26: ...V06 26 RU VDE H05 RN F 3x2 5 2 30 TC 3 PE N L1 3B 3 A B...
Страница 28: ...V06 28 RU A Thermo Cabinets A A...
Страница 29: ...29 V06 RU C F 10 C F 30 C 80 C I...