background image

Thank you for purchasing RATH’s Eco Call Station. We are the largest Emergency Communication 

Manufacturer in North America and have been in business for over 35 years. 

We take great pride in our products, service, and support. Our Emergency Products are of the highest 

quality. Our experienced customer support teams are available to remotely assist with site preparation, 

installation, and maintenance. It is our sincere hope that your experience with us has and will continue 

to surpass your expectations. 

Thank you for your business,

The RATH

®

 Team

N56W24720 N. Corporate Circle    Sussex, WI 53089

800-451-1460    www.rathcommunications.com

Table of Contents

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Items Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone Programming . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjusting The Volume . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3
Page 3
Page 4
Page 4
Page 4
Page 5
Page 6
Page 6
Page 7
Page 8

Содержание 2100-ELL2

Страница 1: ...t Call Station 2100 ELL2 Landline 12v Call Station 2100 ELV2 VoIP POE Call Station N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www rathcommunications com RP8500SCSL Ver 3 10 18 Installation Operations Manual Made in the USA 2 Year Warranty ...

Страница 2: ...remotely assist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business The RATH Team N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www rathcommunications com Table of Contents Description Safety Guidelines Items Needed Installation Communication Phone Programmi...

Страница 3: ...rage Be careful of finished surfaces during transport and installation to avoid damaging the finish Installation and maintenance should only be performed by qualified electricians It is recommended a minimum of 2 people perform installation Do not install phone during extreme weather conditions Do not touch uninsulated phone wires or terminals unless the phone line has been disconnected at the net...

Страница 4: ...motely secure the front assembly to the back panel and reinstall the 8 screws to the sides of the unit If the phone will be programmed on site proceed to the directions for On Site Programming Communication Page 4 Landline To connect your analog phone line to the Emergency Call Station 1 Remove front Stainless Steel plate using the security torx bit to remove the 6 security screws 2 Locate the gra...

Страница 5: ...es Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number of the Call Station B After first simulated ring Press Wait for 4 tones C Key in security code Default is 1111 Wait for confirmation tones Step 2 To Program Emergency Numbers A Press 1 Phone number Wait for confirmation tones Note Emergency numbers 2 5 rep...

Страница 6: ...proceed to the Troubleshooting Section Push the emergency button on the front of the Call Station Yes No RATH recommends the Call Station be tested on a regular basis to ensure proper operation Adjusting the Volume Volume Adjust VR1 Mic Sensitivity VR2 If the volume is too low or high adjust it by referring to the diagram and instructions below Note Refer to the instructions under Programming the ...

Страница 7: ...em is not providing a disconnect signal Contact the appropriate party to make sure the disconnect signal is provided When the called party hangs up busy signal is heard through speaker Phone company or phone system is not providing a disconnect signal Operator needs to press to disconnect the call Disconnect time on phone needs to be lowered see page 6 Call Station appears non functional Strobe do...

Страница 8: ... Pause Stop Constant Strobe to 900 MHz Radio or Cellular y r e t t a B Communication Source LED for Panel FRONT COVER Note If using landline phone cable will just run out of the bottom of the NEMA 4 enclousre 12v Wago Connector Page 8 Wiring Wago Connector ...

Отзывы: