background image

Items Needed for Installation

Installation

1.

 Remove 8 security screws from unit. 

2.

 Pull front assembly away from back unit.

3.

 Disconnect the gray Wago connector (see diagram on page 8).

4.

 If wall mount, mount to wall.

5.

 If pole mount, attach unit to pole using Pole Mounting Bracket (Part # RP7700098AE).

6.

 Connect the electrical conduit of the 12v power supply to the Call Station and run  necessary wires.

7.

 Connect 12v wiring to the Call Station power cable (see diagram on page 8).

8.

 Turn on 12v power to the Call Station.

Once the electrical is “live”, the phone needs to be programmed and tested. Reconnect the Wago connectors  that 

attach the front plate to the NEMA 4 box. If the phone will be programmed remotely, secure the front  assembly to the 

back panel and reinstall the 8 screws to the sides of the unit. If the  phone will be programmed on-site, proceed to the 

directions for “On-Site Programming”.  

Communication

Page 4

Landline:

To connect your analog phone line to the Emergency Call Station:

1.

 Remove front Stainless Steel plate using the security torx bit to remove the 6 security screws.

2.

 Locate the gray phone cable coming out of the NEMA 4 box.

3.

 Connect the incoming phone line by connecting the tip and ring of the phone line to red and green of 

    provided gray line cord.

VoIP:

See additional manual.

Item

Description

Wall Mounting Hardware

If Mounting to Wall

Pole Mount Bracket (Part # RP7700098AE)

If Mounting to Pole

#1 Phillips Screwdriver
Voltage Meter
Security Torx Bit

Provided by RATH®

Adjustable Wrench
12v Power Source or POE
Analog Phone Line

If Using Landline

Phone Cable

If Using Landline

Содержание 2100-ELL2

Страница 1: ...t Call Station 2100 ELL2 Landline 12v Call Station 2100 ELV2 VoIP POE Call Station N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www rathcommunications com RP8500SCSL Ver 3 10 18 Installation Operations Manual Made in the USA 2 Year Warranty ...

Страница 2: ...remotely assist with site preparation installation and maintenance It is our sincere hope that your experience with us has and will continue to surpass your expectations Thank you for your business The RATH Team N56W24720 N Corporate Circle Sussex WI 53089 800 451 1460 www rathcommunications com Table of Contents Description Safety Guidelines Items Needed Installation Communication Phone Programmi...

Страница 3: ...rage Be careful of finished surfaces during transport and installation to avoid damaging the finish Installation and maintenance should only be performed by qualified electricians It is recommended a minimum of 2 people perform installation Do not install phone during extreme weather conditions Do not touch uninsulated phone wires or terminals unless the phone line has been disconnected at the net...

Страница 4: ...motely secure the front assembly to the back panel and reinstall the 8 screws to the sides of the unit If the phone will be programmed on site proceed to the directions for On Site Programming Communication Page 4 Landline To connect your analog phone line to the Emergency Call Station 1 Remove front Stainless Steel plate using the security torx bit to remove the 6 security screws 2 Locate the gra...

Страница 5: ...es Ex 2 minutes 002 Step 5 To Exit Program Mode A Press Stop for 3 seconds Step 1 To Begin Program Mode A Call into phone by dialing the number of the Call Station B After first simulated ring Press Wait for 4 tones C Key in security code Default is 1111 Wait for confirmation tones Step 2 To Program Emergency Numbers A Press 1 Phone number Wait for confirmation tones Note Emergency numbers 2 5 rep...

Страница 6: ...proceed to the Troubleshooting Section Push the emergency button on the front of the Call Station Yes No RATH recommends the Call Station be tested on a regular basis to ensure proper operation Adjusting the Volume Volume Adjust VR1 Mic Sensitivity VR2 If the volume is too low or high adjust it by referring to the diagram and instructions below Note Refer to the instructions under Programming the ...

Страница 7: ...em is not providing a disconnect signal Contact the appropriate party to make sure the disconnect signal is provided When the called party hangs up busy signal is heard through speaker Phone company or phone system is not providing a disconnect signal Operator needs to press to disconnect the call Disconnect time on phone needs to be lowered see page 6 Call Station appears non functional Strobe do...

Страница 8: ... Pause Stop Constant Strobe to 900 MHz Radio or Cellular y r e t t a B Communication Source LED for Panel FRONT COVER Note If using landline phone cable will just run out of the bottom of the NEMA 4 enclousre 12v Wago Connector Page 8 Wiring Wago Connector ...

Отзывы: