Gas Conversion - Grills - L.P. to Natural Gas
Page 17
GAS CONVERSION REQUIRES A CONVERSION KIT, AVAILABLE FROM YOUR SOLAIRE DEALER
For 30" Models, kit includes
For 42" Model & 56*” Models, kit includes
• Two (2) # 250 Main burner orifices.
• Three (3) # 250 Main burner orifices.
*
56” model also requires side burner kit -
see pg. 19 for details
TO CONVERT YOUR SOLAIRE INFRARED GRILL FROM L.P. GAS TO NATURAL GAS, FOLLOW THESE STEPS:
1. Remove the rear top panel from the Grill; this will give access to the regulator (see drawing below).
2. Remove the regulator ‘cap’.
3. Turn it over 180° (see Fig. 12).
4. Replace the regulator ‘cap’ onto the regulator.
5. Remove the Grill cooking grids and the burners, taking care NOT to damage or move the igniter electrodes.
6. The main burner orifices are located at the end of the burner valves (where they enter the burner throat)
and should be unscrewed and put to one side.
7. Replace the old L.P. Gas main burner orifices (# 155) with new Natural Gas orifices (# 250)
8. Refit the rear access panel.
9. Refit the main burners onto the burner valve orifices, taking care not to damage or move the igniter electrodes.
10. After the Grill has been correctly installed and tested for leaks as detailed on Page 6, follow the instructions
for lighting the grill and check the burner characteristics.
11. After establishing that the burner characteristics are correct refit the front control panel and control knobs.
12. Change the indication on the rating plate to show that the unit has been converted to Natural Gas.
13. Your SOLAIRE INFRARED Grill can now be operated on Natural Gas.
NAT GAS
LP GAS