IMPORTANT INSTALLATION REQUIREMENTS

Required Minimum Permanent Chimney Damper Opening:

1.

The chimney damper must be fixed in a manner to maintain a permanent

free opening of at least 39 square inches based on a minimum chimney
height of at least 8 feet. The area of the flue must not be less than 1/10 the
area of the fireplace opening. The flue must exhaust all products of
combustion.
  MINIMUM PERMANENT CHIMNEY OPENING is
accomplished by either  installing the provided damper clamp, permanently
fixing the damper open,  or by drilling holes in the damper blade.

Attaching Damper Clamp:

1.

Install the damper clamp (provided) on the edge of the damper blade to

prevent its closing, or drill holes in the damper.

Damper
Stop Clamp

Damper

Chimney
Flue

   .

WARNING: Minimum Permanent Chimney Damper Opening is the minimum permanent opening required
by Standard or Codes to ensure safe operation of the appliance.  It is not the minimum operating damper
position. 
 When operating this appliance,  THE DAMPER MUST BE WIDE OPEN.  The flue must
vent all products of combustion.

ASSEMBLY (Natural Gas Match Lighted Models Only)

WARNING:  Match Lighted 

L C   ( 1 8 , 2 4 , 3 0 ) - N )

 is for use with natural gas only.  A safety pilot must be

installed on all units designed or converted to burn Propane/LP gas.

Required Tools And Materials:  

Screw Driver, Adjustable Wrench, Pipe Wrench,  Pipe Sealing Compound or Teflon Tape.

Natural Gas Match Lighted Model Assembly

1. Wrench tighten LOCKING PAL NUT (A) onto the non-flared end of 3/8"
ORIFICE HOLDER (B).
2. Thread ORIFICE SPUD (C) into 3/8" ORIFICE HOLDER (B) and tighten.
3. Apply pipe compound to the outside threads of the 3/8" ORIFICE HOLDER
( B ) .    
Thread into TOP BURNER TUBE (D).  Wrench tighten with the flared
connection facing towards rear.
4.  Insert   RATING PLATE/HEAT SHIELD E) between the LOCKING
PALNUT (A) 
and  BURNER TUBE (D).    Wrench tighten LOCKING PAL NUT

B

C

A

D

E

Natural Gas Match Lighted Model with
Accessory V-17  

(For use only with Natural Gas Models

LC (18,24,30)-N) Assembly

1.

Wrench tighten LOCKING PAL NUT (A) onto 3/8" ELBOW (B).

2.

Apply pipe compound to threaded end of 3/8" STREET EL (B).  Thread into

TOP BURNER TUBE (C) and wrench tighten to position shown.
3.

Thread ORIFICE SPUD (D) into 3/8" V-17 VALVE (E) and wrench tighten.

4.

Apply pipe compound to orifice end of 3/8" V-17 VALVE (E). Thread into 3/8"

G

E

F

G

STREET EL (B) and wrench tighten to position shown.
5.

Apply pipe compound to inlet side threads of 3/8" V-17 VALVE

( E ) .  Thread 3/8" CONNECTOR FITTING (F) onto inlet side of
3/8" V-17 VALVE (E) and wrench tighten.
6.

Insert the  RATING PLATE-HEAT SHIELD (G) between  the

LOCKING PAL NUT (A) and BURNER TUBE (D).  Wrench
tighten the LOCKING PAL NUT.
7.

Insert  K E Y   ( G )   sleeve  over 3/8" V-17 VALVE (E) stem.

Insert screw and tighten.

C

A

B

D

INSTALLATION  (All Models)

Burner Pan and Grate Positioning (see Firebox Sizing Requirements-page 2):

REAR WALL

TOP VIEW

1. Place GRATE inside firebox as
far to the rear as possible. Center
GRATE left to right.
2. With open edge facing out, place
BURNER PAN beneath grate with
leading edge approximately one inch
forward of GRATE front legs.
3. Mark positions of GRATE and
BURNER PAN on fire place floor
with pencil. Remove from firebox.

SIDE VIEW

3

Содержание LC-18-N

Страница 1: ...CHIMNEY DAMPER MUST BE FULLY OPEN WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Read these instructions thoroughly before installation For assistance or additio...

Страница 2: ...lled at the installation install a gas valve on the supply line in or just outside the fireplace in accordance with the provisions of the National Fuel Gas Code ANSI Z223 1 Latest Edition or the CSA B149 1 Natural Gas and Propane Installation Guide 3 Natural Gas Operating Pressures The minimum inlet gas supply pressure for the purpose of input adjustment shall be 6 inches of water column The maxim...

Страница 3: ...ed end of 3 8 ORIFICE HOLDER B 2 Thread ORIFICE SPUD C into 3 8 ORIFICE HOLDER B and tighten 3 Apply pipe compound to the outside threads of the 3 8 ORIFICE HOLDER B Thread into TOP BURNER TUBE D Wrench tighten with the flared connection facing towards rear 4 Insert RATING PLATE HEAT SHIELD E between the LOCKING PALNUT A and BURNER TUBE D Wrench tighten LOCKING PAL NUT B C A D E Natural Gas Match ...

Страница 4: ...designed or converted to burn Propane LP gas 2 Sprinkle a light covering of EMBER MAGIC over the PAN MEDIUM Pull apart EMBER MAGIC fiber material to enhance the glowing ember effect BURNER TUBES MEDIUM EMBER MAGIC MEDIUM Spread the remaining EMBER MAGIC around ends of pan to enhance ember bed appearance 3 VOLCANIC ASH may be sprinkled around the OUTSIDE of the BURNER PAN as a decorative effect Log...

Страница 5: ...furnishings and could cause serious illness If improper venting is suspected IMMEDIATELY HAVE LOG SET AND CHIMNEY FLUE SERVICED Periodically examine and clean the venting system Once a year a qualified agency should examine and clean the venting system of your solid fuel burning fireplace MANUAL MATCH LIGHTING For use only with Natural Gas Models LC 18 24 30 N 1 Place lighted match on embers near ...

Страница 6: ...kwise to increase flame Correctly adjusted pilot flame should be steady and soft blue surrounding approximately 1 2 inch of thermocouple tip Never permit tip to exceed a dull red temperature NOTE Ensure Right Front Log position does not allow burner flame to come in contact with Pilot Assembly Direct burner flame on Pilot Assembly may will cause nuisance pilot shut off or damage to pilot Millivolt...

Страница 7: ...ry From THERMOPILE Valve Terminals 3 Way Control Selector Switch To ACCESSORY CONTROL Outside Terminal Piggy Back Outside Terminal THERMOGENERATOR PILOT FLAME 1 2 Pilot Adjustment Switch and Remote Valve 1 The PILOT FLAME should be steady and soft blue surrounding approximately 1 2 inch of the thermocouple tip 2 If pilot flame adjustment is necessary use a narrow long stem screw driver to turn PIL...

Страница 8: ... kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price pa...

Отзывы: