background image

INSTALLATION  (All Models) (Continued)

A

B

C

D

Gas Connection:

ENSURE THAT GAS SUPPLY TO FIREPLACE IS TURNED OFF
1.  Apply pipe compound to threaded end of GAS SUPPLY PIPE (A). Thread
1/2" FIP x 3/8" FLARE ELBOW (B) onto GAS SUPPLY PIPE (A) and
wrench tighten.
2. With BURNER PAN inside firebox at previously marked position, thread (without
pipe compound) one end of the ALUMINUM 

CONNECTOR  TUBE (C) to the

1/2" FIP x 3/8" FLARE ELBOW (B) and wrench tighten.
3. Carefully bend ALUMINUM CONNECTOR TUBE (C), align and connect,
without pipe compound, to the FLARED VALVE INPUT FITTING (D). Wrench
tighten.
NOTE: ALUMINUM CONNECTOR TUBE (C) may kink or break, causing air
flow noise and/or leaks if bent into too small a radius.
4. Turn gas supply to fireplace on.
5. Test all connections for leaks with soapy water  solution. If solution bubbles, turn
off gas supply, re-tighten fitting and recheck.

Pressure Testing:

1.

Use Gas resistant compound on all pipe fittings (Do not use compound on connections with flared fitting).

2.  The gas log set and its individual shutoff valve (if installed) must be disconnected  from  the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).  The gas log set must be isolated from the gas
supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
3.

Test new piping for leaks using soap solution.  Do not use open flame to flame test.

Filling Pans with Medium:

1.

Completely cover BURNER TUBES and EMBER BOOSTER with the

appropriate PAN MEDIUM. The  WHITE SAND is for use with Natural
Gas, 
the  BLACK VOLCANIC ASH is for use with Propane/LP Gas.
Use the  ENTIRE CONTENTS of the bag provided with the burner.

WARNING: 

A safety pilot must be installed on all units

designed or converted to burn Propane/LP gas

2. Sprinkle a light covering of "EMBER MAGIC" over the PAN MEDIUM.  Pull
apart "EMBER MAGIC" fiber material to enhance the glowing ember effect.

BURNER TUBES

MEDIUM

EMBER MAGIC

MEDIUM

Spread the remaining "EMBER MAGIC" around ends of pan to enhance ember bed appearance.
3. VOLCANIC ASH may be sprinkled around the OUTSIDE of the BURNER PAN as a decorative effect.

Log Placement:

1

.  The largest logs will be either the Rear Log or  the Left or Right Front Logs(two separate front logs which simulate a

charred and burnt effect between the two halves). The Large Top Logs are placed across the front and rear logs with the larger top
logs placed first. The remaining L O G S  are placed diagonally across the two large TOP LOGS allowing flame to pass freely
between them. CAUTION: Crowded logs will cause poor combustion and result in excessive soot formation.
NOTE:  Ensure Right Front Log position does not allow burner flame to come in contact with Pilot
Assembly.  Direct burner flame on Pilot Assembly will cause nuisance pilot shut-off or damage to pilot.

Front Logs

Large
Top Log

Small
Top Logs

Small
Top Log

Large
Top Log

FRONT VIEW

Large
Top Logs

Front Logs

Rear Log

Small
Top Logs

TOP VIEW

LIGHTING AND OPERATION

DAMPER MUST BE WIDE OPEN WHILE BURNING

IMPORTANT INFORMATION BEFORE LIGHTING

A fire place screen must be in place when the log set is in
operation and, unless other provisions for combustion air are
provided, the screen shall have opening(s) for introduction of
combustion air.

The area around the gas log set must be clear and free from
combustible materials,  gasoline and any other flammable vapors
and liquids.

The installation and the provision for combustion and ventilation
air must conform with the NATIONAL FUEL GAS CODE ANSI
Z223.1 latest edition.

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.

4

Содержание LC-18-N

Страница 1: ...CHIMNEY DAMPER MUST BE FULLY OPEN WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Read these instructions thoroughly before installation For assistance or additio...

Страница 2: ...lled at the installation install a gas valve on the supply line in or just outside the fireplace in accordance with the provisions of the National Fuel Gas Code ANSI Z223 1 Latest Edition or the CSA B149 1 Natural Gas and Propane Installation Guide 3 Natural Gas Operating Pressures The minimum inlet gas supply pressure for the purpose of input adjustment shall be 6 inches of water column The maxim...

Страница 3: ...ed end of 3 8 ORIFICE HOLDER B 2 Thread ORIFICE SPUD C into 3 8 ORIFICE HOLDER B and tighten 3 Apply pipe compound to the outside threads of the 3 8 ORIFICE HOLDER B Thread into TOP BURNER TUBE D Wrench tighten with the flared connection facing towards rear 4 Insert RATING PLATE HEAT SHIELD E between the LOCKING PALNUT A and BURNER TUBE D Wrench tighten LOCKING PAL NUT B C A D E Natural Gas Match ...

Страница 4: ...designed or converted to burn Propane LP gas 2 Sprinkle a light covering of EMBER MAGIC over the PAN MEDIUM Pull apart EMBER MAGIC fiber material to enhance the glowing ember effect BURNER TUBES MEDIUM EMBER MAGIC MEDIUM Spread the remaining EMBER MAGIC around ends of pan to enhance ember bed appearance 3 VOLCANIC ASH may be sprinkled around the OUTSIDE of the BURNER PAN as a decorative effect Log...

Страница 5: ...furnishings and could cause serious illness If improper venting is suspected IMMEDIATELY HAVE LOG SET AND CHIMNEY FLUE SERVICED Periodically examine and clean the venting system Once a year a qualified agency should examine and clean the venting system of your solid fuel burning fireplace MANUAL MATCH LIGHTING For use only with Natural Gas Models LC 18 24 30 N 1 Place lighted match on embers near ...

Страница 6: ...kwise to increase flame Correctly adjusted pilot flame should be steady and soft blue surrounding approximately 1 2 inch of thermocouple tip Never permit tip to exceed a dull red temperature NOTE Ensure Right Front Log position does not allow burner flame to come in contact with Pilot Assembly Direct burner flame on Pilot Assembly may will cause nuisance pilot shut off or damage to pilot Millivolt...

Страница 7: ...ry From THERMOPILE Valve Terminals 3 Way Control Selector Switch To ACCESSORY CONTROL Outside Terminal Piggy Back Outside Terminal THERMOGENERATOR PILOT FLAME 1 2 Pilot Adjustment Switch and Remote Valve 1 The PILOT FLAME should be steady and soft blue surrounding approximately 1 2 inch of the thermocouple tip 2 If pilot flame adjustment is necessary use a narrow long stem screw driver to turn PIL...

Страница 8: ... kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price pa...

Отзывы: