LIGHTING AND OPERATION (continued)
VALVE OUTLET
FITTING
NOTCHED END OF
HEAT SHIELD
OFF ON
AT PILOT POSITION
SLIGHT PUSH TO
TURN OFF
FULL PUSH TO
LIGHT
Heat Shield:
HEAT SHIELD is placed over the Valve Assembly with the
notched end over the VALVE OUTLET FITTING.
WARNING: HEAT SHIELD MUST BE INSTALLED TO
PREVENT PREMATURE VALVE FAILURE AND/OR
VOIDING OF VALVE MANUFACTURER'S WARRANTY
PILOT
ADJUSTMENT
SCREW
CONTROL KNOB
HEAT SHIELD
+
+
OFF ON
AT PILOT POSITION
SLIGHT PUSH TO
TURN OFF
FULL PUSH TO
LIGHT
Lighting Instructions:
1. Bleed all air from piping leading to control. Carefully re-tighten connection.
2. Turn CONTROL KNOB pointer to "OFF" position. Wait 5 minutes before lighting.
3. Turn CONTROL KNOB pointer to "PILOT" position. Depress CONTROL KNOB and hold down 60 seconds after lighting pilot
burner. Release CONTROL KNOB. Pilot will remain lighted.
4. Turn CONTROL KNOB partially towards the "ON" position. After gas fills burner pan medium, burner will light. Dial may then be
turned to full "ON" or to desired flame height
5. If main or pilot burner extinguishes, turn CONTROL KNOB to "OFF" position. Wait five minutes and repeat above lighting
procedure from step 1.
T O P V I E W
PILOT FLAME
THERMOCOUPLE
1/2"
Pilot Adjustment:
1. Adjust Pilot if necessary. With narrow long stem screw driver, turn P I L O T
ADJUSTMENT SCREW clockwise to reduce size of pilot flame or counterclockwise
to increase flame. Correctly adjusted pilot flame should be steady and soft blue
surrounding approximately 1/2 inch of thermocouple tip. Never permit tip to exceed a
dull red temperature.
NOTE: Ensure Right Front Log position does not allow burner flame to come in contact with Pilot
Assembly. Direct burner flame on Pilot Assembly may will cause nuisance pilot shut-off or damage to pilot.
Millivolt Switch/Remote Ready Safety Control
•
Natural Gas Models LC(18,24,30)-S-N.
•
Propane Gas Models LC(18,24,30)-S-P.
Top Burner
Pan Tube
Burner Input Fitting
Burner orifice
NAT LP
Burner Orifice Orifice
18" #36 #53
24" #29 #49
30" #29 #45
Required Air
Mixer for LP
RPK3-FA
IMPORTANT: When lit, chimney damper must be wide open
Burner Orifice
Burner Orifice:
Burner Orifice is located at valve output fitting.
NOTE: Maximum flame height can be adjusted by changing orifice size, e.g., a
larger orifice results in a larger flame.
NOTE: Over sizing Propane Orifice may result in improper air mixing causing
excessive soot formation on the logs.
Heat Shield:
Heat shield is [laced over the valve assembly by Inserting the notched portion of
the Heat Shield between the Valve outlet 3 / 8 M I P x 3 / 8
Heat Shield
F I P Elbow and the 3 / 8 F l a r e d x 3 / 8 M I P
Elbow
Ensure that the Heat Shield is over the VALVE
ASSEMBLY. Pilot tubing and wire leads should be
behind the shield exiting towards the rear.
CAUTION: The safety control valve
must be protected to a max ambient
temperature of 175° F. Excessive
heat to the valve is indicated by
melted plastic on the valve body.
VALVE
Heat
Shield
(Top
View)
6