IMPORTANT INSTALLATION REQUIREMENTS

THIS BURNER FOR USE ONLY IN A FULLY FUNCTIONING SOLID FUEL BURNING

FIREPLACE CONSTRUCTED OF NON COMBUSTIBLE MATERIAL WITH A WORKING

FLUE.

WHEN OPERATING, THE DAMPER MUST BE WIDE OPEN.  THE FLUE MUST VENT ALL

PRODUCTS OF COMBUSTION.

TO PROVIDE AIR FOR SAFE COMBUSTION, COMPONENT COOLING AND VENTING,

GLASS DOORS MUST BE KEPT WIDE OPEN WHEN THE BURNER IS ON .  AFTER USE,

ALLOW GAS LOGS TO COOL BEFORE CLOSING GLASS DOORS.

I

nstallation Requirements:

THIS BURNER IS FOR USE ONLY IN A FULLY FUNCTIONING WOOD BURNING FIREPLACE WITH

THE DAMPER WIDE OPEN.  THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.

1

.

The installation and the provisions for combustion and ventilation air must conform with the 

National Fuel Gas Code  ANSI Z223.1 -

Latest Edition

 or the 

CSA B149.1 Natural  Gas and Propane Installation Guide

.

2.  A manufactured home (USA only) or mobile home OEM installation must conform with the (U.S.) 

Manufactured Home Construction

and  Safety Standard, Title 24 CFR, part 3280, 

 or, when such a standard is not applicable, the Standard for 

Fire Safety Criteria for

Manufactured Home Installation Sites and Communities, ANSI/NFPA 501A,

 the U.S., or the 

Mobile Homes Standard, CAN/CSA-Z240

MH series

 in Canada.

Gas Supply and Pressure Requirements:

1.

Verify appliance gas type:  Verify that the Burner-Valve assembly is correctly matched to the  gas supply.

NATURAL GAS

L C - ( 1 8 , 2 4 , 3 0 ) - N

MATCHLIT Only

Pan filler = White Sand

NATURAL GAS

L C - ( 1 8 , 2 4 , 3 0 ) - M - N

L C - ( 1 8 , 2 4 , 3 0 ) - S - N

Pan filler = White Sand

PROPANE GAS

L C - ( 1 8 , 2 4 , 3 0 ) - M - P

L C - ( 1 8 , 2 4 , 3 0 ) - S - P

Pan Filler = Volcanic Ash

          NOTE: Propane Valve Assemblies can be quickly identified by the Air Mixer hole present on the Black Iron Coupling.

WARNING:

MATCHLIT BURNER IS NOT DESIGNED FOR USE WITH PROPANE/LP
GAS.  A SAFETY PILOT MUST BE INSTALLED ON ALL UNITS DESIGNED
OR CONVERTED TO BURN PROPANE/LP GAS

2.

If local gas supply valve is not already installed at the installation, install a gas valve on the supply line in or just outside the

fireplace in accordance with the provisions of the 

National Fuel Gas Code  ANSI Z223.1 - Latest Edition

 or the 

CSA B149.1 Natural  Gas

and Propane Installation Guide

.

3.

Natural Gas Operating Pressures:  The minimum inlet gas supply pressure for the purpose of input adjustment shall be 6

inches of water column.  The maximum inlet gas supply pressure shall be 7 inches of water column.
4.

Propane Gas Operating Pressures:  The minimum inlet gas supply pressure for the purpose of input adjustment shall be 11

inches of water column.  The maximum inlet gas supply pressure shall be 14 inches of water column.

The gas supply  must be regulated prior to input into the appliance.  Never connect this

appliance directly to an unregulated Propane tank.  Do not conduct line pressure testing in

excess of 1/2 psig without first isolating the appliance. see Pressure Testing, page 4.

Firebox Requirements:

1.

This gas log set must only  be installed  in a  solid-fuel burning fireplace constructed of non combustible material with a working

flue.  The flue must be operable and must exhaust all products of combustion.

Firebox Sizing Requirements:

2.

The minimum size (in inches) of the fireplace in which the log set is to be installed must be in accordance with the "MINIMUM

FIREPLACE SIZE IN INCHES" below:

MINIMUM FIREPLACE SIZE IN INCHES

LOG SET SIZE

HEIGHT

D E P T H

FRONTWIDTH

CHIMNEY

18 INCH
24 INCH

30 INCH

.

16
16
16

16
16
16

26
38
36

7 INCH DIAMETER
7 INCH DIAMETER

8 INCH DIAMETER

.

Required Fireplace Preparation Prior to Installation:

1.

Firebox and chimney damper/flue must be  thoroughly cleaned (if previously used for either gas or wood burning.)

WARNING: Before installing in a solid fuel burning fireplace,  the chimney flue and firebox
must  be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

2.

The area around the installation  must be clear and free from combustible materials, gasoline and any other flammable vapors and

liquids. Provide adequate clearances for servicing and proper operation.

2

Содержание LC-18-N

Страница 1: ...CHIMNEY DAMPER MUST BE FULLY OPEN WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Read these instructions thoroughly before installation For assistance or additio...

Страница 2: ...lled at the installation install a gas valve on the supply line in or just outside the fireplace in accordance with the provisions of the National Fuel Gas Code ANSI Z223 1 Latest Edition or the CSA B149 1 Natural Gas and Propane Installation Guide 3 Natural Gas Operating Pressures The minimum inlet gas supply pressure for the purpose of input adjustment shall be 6 inches of water column The maxim...

Страница 3: ...ed end of 3 8 ORIFICE HOLDER B 2 Thread ORIFICE SPUD C into 3 8 ORIFICE HOLDER B and tighten 3 Apply pipe compound to the outside threads of the 3 8 ORIFICE HOLDER B Thread into TOP BURNER TUBE D Wrench tighten with the flared connection facing towards rear 4 Insert RATING PLATE HEAT SHIELD E between the LOCKING PALNUT A and BURNER TUBE D Wrench tighten LOCKING PAL NUT B C A D E Natural Gas Match ...

Страница 4: ...designed or converted to burn Propane LP gas 2 Sprinkle a light covering of EMBER MAGIC over the PAN MEDIUM Pull apart EMBER MAGIC fiber material to enhance the glowing ember effect BURNER TUBES MEDIUM EMBER MAGIC MEDIUM Spread the remaining EMBER MAGIC around ends of pan to enhance ember bed appearance 3 VOLCANIC ASH may be sprinkled around the OUTSIDE of the BURNER PAN as a decorative effect Log...

Страница 5: ...furnishings and could cause serious illness If improper venting is suspected IMMEDIATELY HAVE LOG SET AND CHIMNEY FLUE SERVICED Periodically examine and clean the venting system Once a year a qualified agency should examine and clean the venting system of your solid fuel burning fireplace MANUAL MATCH LIGHTING For use only with Natural Gas Models LC 18 24 30 N 1 Place lighted match on embers near ...

Страница 6: ...kwise to increase flame Correctly adjusted pilot flame should be steady and soft blue surrounding approximately 1 2 inch of thermocouple tip Never permit tip to exceed a dull red temperature NOTE Ensure Right Front Log position does not allow burner flame to come in contact with Pilot Assembly Direct burner flame on Pilot Assembly may will cause nuisance pilot shut off or damage to pilot Millivolt...

Страница 7: ...ry From THERMOPILE Valve Terminals 3 Way Control Selector Switch To ACCESSORY CONTROL Outside Terminal Piggy Back Outside Terminal THERMOGENERATOR PILOT FLAME 1 2 Pilot Adjustment Switch and Remote Valve 1 The PILOT FLAME should be steady and soft blue surrounding approximately 1 2 inch of the thermocouple tip 2 If pilot flame adjustment is necessary use a narrow long stem screw driver to turn PIL...

Страница 8: ... kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price pa...

Отзывы: