Hardware Installation
User Manual
ApplianceStor
50
Rev. 1, November 2011
34
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system displays the status
of the RAID volume as "Degraded" during POST. You can rebuild the RAID array with other installed
non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1.
At the prompt, press <Ctrl> + <I> to enter the Intel Rapid Storage Technology option ROM
utility.
2.
If there is a non-RAID SATA Hard Disk available, the utility will prompt to rebuild the RAID.
Press <Enter>, and then use up/down arrow keys to select the destination disk or press
<ESC> to exit.
Figure 43-Rebuild RAID
Select a destination disk with the same size as the original hard disk.
3.
The utility immediately starts rebuilding after the disk is selected. The status
Figure 44- Select recovery disk
4.
of the degraded RAID volume is changed to "Rebuild".
5.
Exit Intel Rapid Storage Technology and reboot the system.
6.
Select Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console or click the Intel
Rapid Storage Technology tray icon to load the Intel Rapid Stroage Manager utility.
Содержание ApplianceStor 50
Страница 1: ...Manual contents ApplianceStor50 Performance Storage Server User Manual 1th Edition November 2010 ...
Страница 29: ...Introduction User Manual ApplianceStor 50 Rev 1 November 2011 11 LAN RJ 45 LEDs Figure 6 NIC LEDs ...
Страница 30: ...Packing Checklist Chapter 2 Before You Begin ...
Страница 61: ...Hardware Installation User Manual ApplianceStor 50 Rev 1 November 2011 43 Figure 56 Finish chipset install ...
Страница 65: ...Hardware Installation User Manual ApplianceStor 50 Rev 1 November 2011 47 Figure 62 Install finish ...
Страница 71: ...Mother board Jumpers Connectors LEDs BIOS Chapter 5 Advanced System Use and Maintenance ...
Страница 80: ...Advanced System Use Maintenance User Manual ApplianceStor 50 Rev 1 November 2011 62 ...