Chapter 7: Device Management
166
Blade chassis
Required/recommended action
•
Exit the iKVM GUI menu before attaching Dell's chassis to a
Raritan CIM. iKVM may not work correctly if this is not done.
•
Configure the iKVM GUI Main menu to select target blades by
Slot, not by Name. iKVM may not work correctly if this is not
done.
•
Do not
designate any slots for scan operations in the iKVM
GUI Setup Scan menu. iKVM may not work correctly
otherwise.
•
Do not
designate any slots for broadcast keyboard/mouse
operations in the iKVM GUI Setup Broadcast menu. iKVM may
not work correctly otherwise.
•
Designate a single key sequence to invoke the iKVM GUI.
This key sequence must also be identified during Dominion
KX II port configuration. Otherwise, indiscriminate iKVM
operation may occur as a result of client key entry.
•
Ensure that Front Panel USB/Video Enabled is
not
selected
during iKVM configuration via the Dell CMC GUI. Otherwise,
connections made at the front of chassis will take precedence
over the Dominion KX II connection at the rear, preventing
proper iKVM operation. A message will be displayed stating
'User has been disabled as front panel is currently active.'
•
Ensure that 'Allow access to CMC CLI from iKVM' is
not
selected during iKVM configuration via the Dell CMC GUI.
•
To avoid having the iKVM GUI display upon connecting to the
blade chassis, set the Screen Delay Time to 8 seconds.
•
Recommend that 'Timed' and 'Displayed' be selected during
iKVM GUI Flag Setup. This will allow you to visually confirm
the connection to the desired blade slot.
Dell PowerEdge
1855/1955
•
Disable the iKVM GUI screensaver. An Authorize dialog will
appear if this is not done and will prevent the iKVM from
operating correctly.
•
Exit the iKVM GUI menu before attaching Dell's chassis to a
Raritan CIM. iKVM may not work correctly if this is not done.
•
Configure the iKVM GUI Main menu to select target blades by
Slot, not by Name. iKVM may not work correctly if this is not
done.
•
Do not
designate any slots for scan operations in the iKVM
GUI Setup Scan menu or the iKVM may not work properly.
•
To avoid having the iKVM GUI display upon connecting to the
blade chassis, set the Screen Delay Time to 8 seconds.
•
Recommend that 'Timed' and 'Displayed' be selected during
iKVM GUI Flag Setup. This will allow you to visually confirm
the connection to the desired blade slot.
Содержание Dominion KX II
Страница 10: ......
Страница 14: ...Chapter 1 Introduction 4...
Страница 16: ...Chapter 1 Introduction 6 Product Photos Dominion KX II KX2 832...
Страница 17: ...Chapter 1 Introduction 7 KX2 864...
Страница 89: ...Chapter 4 Virtual Media 79...
Страница 111: ...Chapter 6 User Management 101...
Страница 144: ...Chapter 7 Device Management 134 3 Click OK...
Страница 154: ...Chapter 7 Device Management 144 3 Click OK...
Страница 198: ...Chapter 9 Security Management 188 3 You are prompted to confirm the deletion Click OK...
Страница 277: ...Appendix B Updating the LDAP Schema 267...
Страница 324: ......