24
3.
Remove the module for the membrane from the electromagnetic valve.
4.
Wipe the (A) plastic cap, (B) membrane module and (C) electromagnet completely
clean of any coffee grounds or particles.
√
√
NOTE:
If the O-ring in the plastic cap falls out or gets dislodged during the
cleaning process, ensure that the O-ring is re-installed into the cap.
Failure to re-install the O-ring may cause the electromagnetic valve to
not work correctly.
5.
Reverse the steps above to re-install the electromagnetic valve.