23
4.
Remove the two black M2.5x5 round Phillips head self-tapping screws securing the
electromagnetic valve in place and then remove the valve from the machine.
To install the electromagnetic valve, reverse the steps above.
Cleaning the Electromagnetic Valve
1.
Remove the electromagnetic valve from the machine. See “Replacing the
Electromagnetic Valve” on page 21 for instructions.
2.
Remove the two M3x6.2 machine-tapping screws securing the plastic cap in place,
and then remove the cap from the electromagnetic valve.