22
√
√
NOTE:
The cable is bundled together with several other cables with a plastic
cable tie which must be cut in order to remove the electromagnetic
valve. After replacing the valve, re-bundle the cables together with a
new cable tie in the same location.
3.
Disconnect the (A) output and (B) intake tubes from the electromagnetic valve.
√
√
NOTE:
When re-installing, ensure that the liquid output tube is connected to
the (A) inner valve and the liquid intake tube is connected to the (B)
outer valve.
A
B
A
B