Calibrating the scanner

You

 

need

 

to

 

perform

 

calibration

 

in

 

order

 

to

 

ensure

 

the

 

work

 

of

 

the

 

scanner

 

after the

adjustment of lenses.

 

Specifically

 

for

 

this

 

purpose

 

we

 

use

 

the

 

calibration plate, which is

pre-measured with

 

high

 

accuracy

 

.

 

Scanning

 

software

 

analyzes

 

the

 

image of the plate,

obtained from the

 

cameras

 

and

 

compares

 

it

 

with

 

the

 

mathematical model, marked by

the algorithm.

There

 

are

 

3

 

types

 

of

 

calibration:

 

Full

 

calibration

automatic

 

calibration

,

fast calibration

(orientation)

and

Calibration of

 

turntable

 

(finding

 

the

 

table

 

axis)

.

Full

 

and

 

automatic

 

calibrations

 

are

 

used:

before

 

work

 

with

 

the

 

scanner,

after

 

transporting

 

the

 

scanner.

Fast

 

calibration

 

is

 

used:

if

 

you

 

suspect

 

that

 

the

 

camera

 

moved

 

due

 

to

 

unreliable

 

mounting,

if

 

you

 

want

 

to

 

check

 

the

 

accuracy

 

of

 

performed

 

calibration.

Calibration

 

of

 

rotary

 

table

 

is

 

performed:

in

 

case

 

of

 

any

 

change

 

in

 

the

 

position

 

of

 

the

 

rotary

 

table

 

to

 

the

 

scanner

(when

 

scanning

 

on

 

the

 

turntable).

Calibration

 

of

 

rotary

 

table

 

is

 

described

 

in

 

the

 

Scanning

 

on

 

the

 

turntable

section.

Calibration

 

plate

Calibration

 

plate

 

is

 

a

 

special

 

plate

 

with

 

markers,

 

the

 

distance

 

between

 

which

 

is

measured with

 

high

 

accuracy.

 

It

 

is

 

used

 

for

 

setting

 

up

 

a

 

scanner

 

and

 

its

 

calibration.

10

Содержание NEO

Страница 1: ...RANGEVISION Setup and calibration NEO...

Страница 2: ...ckage contents 5 Installing software and drivers 6 Setting up your computer for work with the scanner 7 Connecting projector 7 Configuring computer parameters 8 Scanner assembly 9 Calibrating the scan...

Страница 3: ...the procedures for preparing the scanner installing the required drivers calibration procedure scanning procedure and tips for acquiring high quality three dimensional object model Information may be...

Страница 4: ...3 Texture scanning yes FOV 300 240 240 mm 3D point accuracy 0 06 mm 3D resolution 0 18 mm Working distance 45 cm System requirements operating system Windows 7 8 10 64bit processor Intel Core i3 i5 1...

Страница 5: ...n plate and a stand for the calibration plate which are used to calibrate the scanner Name qty 1 Scanning module Mounting structure with projector 1 Cable kit for PC connection USB HDMI 1 2 Tripod 1 3...

Страница 6: ...esired language type and path for installation After the files have been copied install drivers and graphics libraries necessary for the correct operation of RangeVision 3D scanner If you have access...

Страница 7: ...ctor First connect the USB to power up the projector and then connect it to the HDMI port of your video card After connecting the projector it should be displayed in the system If the computer has sev...

Страница 8: ...recurrence of the problems during the scanner operation you must turn off the screensaver and sleep mode Go to Screen Saver Settings menu and turn off the screen saver disable turning off the display...

Страница 9: ...nning module onto the tripod 2 Connect USB cable to your PC 3 Connect HDMI cable to your PC 4 When using the turntable connect it to the power source then connect the USB cable to your PC and turn the...

Страница 10: ...turntable finding the table axis Full and automatic calibrations are used before work with the scanner after transporting the scanner Fast calibration is used if you suspect that the camera moved due...

Страница 11: ...down list choose the correct calibration plate size specified on the back side of the plate or add a new one It is possible that camera images in the software will be swapped or flipped from the start...

Страница 12: ...cameras matches the markers on the plate the cross is projected on the central marker 3 If the plate placement is incorrect an error message will appear Correct the placement and repeat the step In c...

Страница 13: ...advice on calibration do not change the distance from the center of the plate to the scanner when turning the plate The exception are only snapshots in positions 10 and 11 do not rotate the plate at a...

Страница 14: ...uring orienting starts to be very different from the original one you need to re calibrate the equipment Example The initial accuracy is 0 084 accuracy after orientation is 0 25 The value exceeded 0 2...

Страница 15: ...wn to the right is in compliance with Waste Electrical and Electronic Equipment Directive 2002 96 EC WEEE The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste bu...

Отзывы: