15

Program 20 – Aluminum

Program 21 – User definable
Program 22 – User definable
Program 23 – User definable
Program 24 – User definable

10.2.

Menu Definitions

Baseline Sensitivity – Sets unit sensitivity range between 1 (minimum) and 99 (highest)

Alarm Tone – Sets the frequency of the alarm to 500,100 or 1500 hertz.

Alarm Volume – Sets the volume of the alarm in steps between 0 and 7.

Alarm hold Time – Sets the time the LED alarm indication is on after an alarm. This value is
between approximately 1 second and 99 seconds. This function is disabled if the IR Sensor is set
to 1.Or on.

IR Sensor – Enables or disables the intelligent sensor. This activates the unit for a short time
while the person is passing through the detector. If your installation is near an elevator, moving
door, or large moving objects, which trigger the unit, you may want to consider this approach.
This function only works with unit equipped with a sensor.

Target Filter – Sets the amount of low frequency filtering needed to reduce noise in the target
spectrum.

Skew Frequency – Sets the unit in different frequencies in order to work with multiple units.

Wide mode – Enables or disables the wide mode of operation. This is use on detectors with wider
than the normal 30 inches distance between side panels.

Zone Settings – Sets the amplification/ attenuation of the 6 horizontal zones. This is the same as
the IDC values, 1 to 99 is amplification, and 1 to 99 is attenuation.

IDC Controls – This is a feature to help the customer, which has a need to build their own
program to detect, or not detect, a particular object. Each object, when passed though the detector,
shows positive and negative numbers. This is due to the signals going positive and negative.
Ferrous and Non Ferrous materials will go in opposite directions when passed to the middle of the
detector. Programs 17 and 18 are to enable only one reading on the display to enable the user to
set values they want to enhance or reduce. Each program can have up to 7 “windows”, each being

Содержание INTELLISCAN SIX ZONE

Страница 1: ...N SIX ZONE Multi Zone Walk Through Security Metal Detector Ranger Security Detectors Inc 11900 Montana Avenue El Paso TX 79936 Telephone 915 590 4441 Fax 915 592 1043 Web site www rangersecurity com E mail support rangersecurity com Version 9 9 ...

Страница 2: ...ction 10 3 Suggested Parameters for O T P Security Level Section 10 4 F A A Three Gun test Security Level Section 10 5 Suggested Parameters for Three Gun Security Level Section 10 6 Higher Security Weapons Detection Section 10 7 Suggested Parameters for Higher Security Weapons Section 10 8 Industrial Applications Section 11 0 Eliminating False Alarms Section 12 0 Operating Multiple Detectors in Pa...

Страница 3: ...sing A built in display panel provides instant visual identification of the exact location of a suspected weapon or weapons in the archway area Detection Programs The Intelliscan Six Zone has 20 detection programs They have been designed for both weapon screening and asset protection applications The weapon screening applications are designed for various threat levels and provide good detection of...

Страница 4: ...ne provides nine user selectable operation frequencies allowing simultaneous operation of multiple units without interconnecting slaving cables Memory The Intelliscan Six Zone utilizes an embedded microprocessor Whenever adjustments are made to the operating parameters they are automatically retained in memory When the detector is powered down the previously entered operating parameters are retain...

Страница 5: ...5 ...

Страница 6: ...6 1 1 PARTS LIST AND DIAGRAM Parts List 1 Header Electronics enclosure 2 Side Panel A 3 Side Panel B 4 8 Flat Washers 5 8 2 Socket Head 6 8 5 8 Plugs 7 Ten Foot Power Cord Parts Diagram ...

Страница 7: ...ble floor control enables uniform detection to be achieved throughout the detector as the upper zone can be operated independently at normal sensitivity levels Intelliscan Six Zone s Multiple Zone Detection increases the throughput rate of people being screened A decrease in unwanted alarms from harmless personal metal objects coupled with the ability to identify the location of weapon sized objec...

Страница 8: ... A trough 90 degrees so the top socket is facing the Header Assembly see Figure 2 Align the top of the Side Panel with the top of the Header Assembly and insert the Header Assembly interconnection cable firmly into the Side Panel Socket Tighten the connector s securing screws Next insert the four Allen Bolts with washers into Side Panel and start screwing them into the Header Assembly Do not tight...

Страница 9: ...ader Assembly power cord First Remove the Header Assembly s top access panel The black power cord should be moved from the right hand to the left hand bulkhead compartment and inserted into Side Panel A s power socket Figure 4 refers Once the Side Panel has been secured raise the unit to the upright position and connect the power cord into the outer surface of the appropriate Side Panel Again chec...

Страница 10: ... Display provides information on alarm events signal strength and abnormal conditions such as high noise and or metal overload conditions Turn the unit on by inserting the key into the Key switch and turning it clockwise All the L E D elements light up in sequence one at a time The L C D Panel displays a SELF TEST message while a self diagnostic test is in progress Next it reads CALIBRATION During...

Страница 11: ...in reverse direction Backspace Bks Deletes what has been typed allows for corrections Nominal Nom Resets the settings to the nominal operating parameters original operating values set at the factory Escape Esc Escapes from the scrolling menu program and back to the normal operating mode Reset Rst Recalibrates the unit ...

Страница 12: ...nt occurs an L E D illuminates and depicts the exact position of the object 2 Twelve segment real time signal strength bargraph shows signal strength of objects that pass through the archway Signal level rises as metal is inserted If the signal level rises into the red area the unit alarms Number of bars that are illuminated is proportional to object size 3 Alarm indicator light red L E D lights a...

Страница 13: ...lect appears on the L C D menu Push M select PGL Threat Aviation current 1 new appears on the L C D Any of the 20 programs can be selected See section on program settings Push M select Baseline sensitivity current 50 new appears on the L C D Select new sensitivity Push M select Alarm tone 1 3 current 2 new appears on the L C D select new tone Push M select Alarm Volume 0 7 current 4 new appears on...

Страница 14: ... Program 1 Low threat Aviation Program 2 Medium threat Aviation Program 3 High threat Aviation Program 4 Low threat Federal Buildings Program 5 Medium threat Federal Buildings Program 6 High threat Federal Buildings Program 7 low threat prisons Program 8 Medium threat prisons Program 9 High threat prisons Program 10 Low threat Public Areas Program 11 Medium threat Public Areas Program 12 High thre...

Страница 15: ...uipped with a sensor Target Filter Sets the amount of low frequency filtering needed to reduce noise in the target spectrum Skew Frequency Sets the unit in different frequencies in order to work with multiple units Wide mode Enables or disables the wide mode of operation This is use on detectors with wider than the normal 30 inches distance between side panels Zone Settings Sets the amplification ...

Страница 16: ... only affects some areas of the detector 10 3 O T P Security Level The Operation Test Piece O T P simulates the detection response from a small revolver and is manufactured to the specifications of the U S Federal Aviation Administration The O T P should be carried with its barrel down and butt to the right The O T P must be detected 100 of the time as the person walks though the unit This securit...

Страница 17: ... by external electromagnetic interface of a frequency comparable the operating frequency of the detector In practice the detector interprets the interference as a signal caused by metal The operating frequency can be changed by changing the values of Skew Frequency There are 8 different combinations of frequencies from 1 to 8 13 0 OPERATING MULTIPLE DETECTORS IN PARALLEL If multiple detectors must...

Страница 18: ...ount of metal the weapon or test object will not be detected at ground level It may be possible to achieve detection by simply increasing the sensitivity of Zone 6 to a high positive value Incrementally increase Zone 6 sensitivity in 5 steps and check if weapon test object is detected at each step 16 0 HORIZONTAL AXIS GAIN CONTROL Section 14 and 15 describe how zone sensitivities can be precisely ...

Страница 19: ...an operating perspective the above characteristics mean that variations in metal compositions can produce some unpredictable results For example a small handgun may generate a much stronger detection response than a weapon that is physically much larger 18 0 MAINTENANCE AND REPAIR There are no user adjustable controls inside the unit If equipment fails to perform properly contact the factory techn...

Страница 20: ...Security Detectors Inc Telephone Number 915 590 4441 11900 Montana Avenue Toll Free Number 800 852 8266 El Paso Texas 79936 Fax Number 915 592 1043 Website www rangersecurity com E mail support rangersecurity com ...

Отзывы: