15
Program 20 – Aluminum
Program 21 – User definable
Program 22 – User definable
Program 23 – User definable
Program 24 – User definable
10.2.
Menu Definitions
Baseline Sensitivity – Sets unit sensitivity range between 1 (minimum) and 99 (highest)
Alarm Tone – Sets the frequency of the alarm to 500,100 or 1500 hertz.
Alarm Volume – Sets the volume of the alarm in steps between 0 and 7.
Alarm hold Time – Sets the time the LED alarm indication is on after an alarm. This value is
between approximately 1 second and 99 seconds. This function is disabled if the IR Sensor is set
to 1.Or on.
IR Sensor – Enables or disables the intelligent sensor. This activates the unit for a short time
while the person is passing through the detector. If your installation is near an elevator, moving
door, or large moving objects, which trigger the unit, you may want to consider this approach.
This function only works with unit equipped with a sensor.
Target Filter – Sets the amount of low frequency filtering needed to reduce noise in the target
spectrum.
Skew Frequency – Sets the unit in different frequencies in order to work with multiple units.
Wide mode – Enables or disables the wide mode of operation. This is use on detectors with wider
than the normal 30 inches distance between side panels.
Zone Settings – Sets the amplification/ attenuation of the 6 horizontal zones. This is the same as
the IDC values, 1 to 99 is amplification, and 1 to 99 is attenuation.
IDC Controls – This is a feature to help the customer, which has a need to build their own
program to detect, or not detect, a particular object. Each object, when passed though the detector,
shows positive and negative numbers. This is due to the signals going positive and negative.
Ferrous and Non Ferrous materials will go in opposite directions when passed to the middle of the
detector. Programs 17 and 18 are to enable only one reading on the display to enable the user to
set values they want to enhance or reduce. Each program can have up to 7 “windows”, each being