![BEINAT RGX1002 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/beinat/rgx1002/rgx1002_manual_2723717001.webp)
CONFORMITY
230 VA
230 VAC
Guide
use and installation
Please read these installation and use instructions
carefully and keep them for future reference. The
manufacturer reserves the right to introduce all the
technical and constructive changes it deems necessar
EN 50194
CEI 216-3
EN 50270
Di Installazione EN 60079-29-2
Report rilasciati da TUV Italia
The appliance assembly / maintenance operations must be carried out in the absence of mains voltage.
Household Methane or LPG gas detector RGX100
2
BUILT ACCORDING TO REGULATIONS EN 50194-1 - EN 50270
Belonging to
The elegance and the prestige, that have always made BEINAT S.r.l stand out from its competitors, together with the
concept of home fitness comes the household gas detector RGX100
2
detects through the catalytic sensor , the
presence of explosive gas such as: Methane or LPG.
Gas detection
The detector is tested and calibrated to 10% of L.E.L.
Through the built-in relay, the RGX100
2
can activate: solenoid valves, sirens, and any other device alarm.
A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.
through an internal jumper it is possible to select the relay impulse functioning, to connect manual reset solenoid
valves, or the continuous functioning, to activate class “A” solenoid valves and sirens.
The relay, free of voltage, allows installation of multiple detectors on a single solenoid valve ensuring control of
multiple dangerous environments.
The detector is complete with a special circuit that controls the catalytic sensor’s efficiency level, and signals
any possible fault.
The enclosure with IP42 degree of protection can be installed either on the wall or on a 503 flush-mounted box.
Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.
Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side
Channel: Beinat gas solutions
Electric connections also available on
TO PROTECT YOUR FAMILY