S+S Regeltechnik AERASGARD AC02-SD-TYR2 Скачать руководство пользователя страница 1

AERASGARD

® 

ACO

- SD -TYR2

AERASGARD

® 

ATM - CO

- SD -TYR2

D G F r

Herzlichen Glückwunsch!  
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!  
You have bought a German quality product.
Félicitations !    
Vous avez fait l’acquisition d’un produit allemand de qualité.
Примите наши поздравления !   
Вы приобрели качественный продукт, изготовленный в Германии.

D

  

Bedienungs- und Montageanleitung

Aufputz- CO

2

 - Fühler  bzw.  Messumformer,   

mit Mehrbereichsumschaltung  
und aktivem ⁄ schaltendem Ausgang

G

  

Operating Instructions, Mounting & Installation

On-wall CO

2

 sensors and measuring transducers,  

with multi-range switching  
and  active  ⁄ switching  output

F

  

Notice d’instruction

Sonde (transmetteur) de CO

2

 pour montage en saillie,  

avec commutation multi-gamme  
et sortie active ⁄ tout ou rien

r

  

Руководство по монтажу и обслуживанию

Датчик  ⁄ измерительный преобразователь содержания  
углекислого газа, для открытой установки, 
с переключением диапазонов измерения  
и активным  ⁄ релейным выходом

ACO

2

 - SD - TYR2  

ATM - CO

2

 - SD - TYR2

6003-3400-2017-000

  33400-000  V101

    12  ⁄  2016

S+S REGELTECHNIK GMBH 
PIRNAER STRASSE 20 
90411 NÜRNBERG ⁄ GERMANY

FON  +49 (0) 911 ⁄ 5 19  47- 0 
FAX  +49 (0) 911 ⁄ 5 19  47- 70

[email protected] 
www.SplusS.de

Содержание AERASGARD AC02-SD-TYR2

Страница 1: ...ereichsumschaltung und aktivem schaltendem Ausgang G Operating Instructions Mounting Installation On wall CO2 sensors and measuring transducers with multi range switching and active switching output F...

Страница 2: ...AERASGARD ACO2 SD TYR2 AERASGARD ATM CO2 SD TYR2 D G F r Ma zeichnung Dimensional drawing Plan cot ACO2 SD TYR2 ATM CO2 SD TYR2 126 112 90 50 4 20 112 M16x1 5...

Страница 3: ...ahme 3 VA bei 24 V DC KOHLENDIOXID CO2 Sensor CO2 optischer NDIR Sensor nicht dispersive Infrarot Technologie Zweistrahl Messverfahren mit automatischer Kalibrierung Messbereich CO2 Mehrbereichsumscha...

Страница 4: ...ibrierung verwendet Stattdessen kann mittels des ent sprechenden Abgleich Potentiometers bei Bedarf der Ausgabewert um bis zu 500 ppm korrigiert werden Inbetriebnahme Nach dem Einschalten des Ger tes...

Страница 5: ...r entfallen alle Gew hrleistungsanspr che Dieses Ger t darf nicht in der N he von W rmequellen z B Heizk rpern oder deren W rmestrom eingesetzt werden eine direkte Sonnen einstrahlung oder W rmeeinstr...

Страница 6: ...E CO2 Sensor CO2 optical NDIR sensor non dispersive infra red technology dual beam measuring system with automatic calibration Measuring range CO2 multi range switching selectable via DIP switches 0 2...

Страница 7: ...omatic calibration is not used Instead the output value can be corrected by up to 500 ppm by means of the corresponding calibration potentiometer if required Putting in operation After switching on th...

Страница 8: ...fications made by the user all warranty claims are forfeited This device must not be installed close to heat sources e g radiators or be exposed to their heat flow Direct sun irradiation or heat irrad...

Страница 9: ...RISTIQUES TECHNIQUES Alimentation en tension 24 V ca cc Consommation lectrique moyenne 3 VA 24 V cc DIOXYDE DE CARBONE CO2 Capteur CO2 capteur optique NDIR technologie infrarouge non dispersive proc...

Страница 10: ...is En cas de besoin il est cependant possible de corriger la valeur de sortie jusqu 500 ppm au moyen du potentiom tre de r glage correspondant Mise en service Apr s la mise en marche de l appareil cel...

Страница 11: ...inue de nos produits En cas de modifications des appareils par l utilisateur tous droits de garantie ne seront pas reconnus Cet appareil ne doit pas tre utilis proximit des sources de chaleur par ex r...

Страница 12: ...IR AERASGARD 2 NDIR 2 24 B 3 24 CO2 CO2 NDIR CO2 DIP 0 2000 1 0 5000 1 CO2 0 10 B CO2 2000 1 70 1 5 5000 1 70 1 10 10 1 K 25 C 1 5 2 0 50 C 0 10 B 1 10 50 C 95 2 0 14 1 5 30 RAL 9016 126 x 90 x 50 Tyr...

Страница 13: ...SD TYR2 Standard AERASGARD ATM CO2 SD TYR2 Standard WG02 CO2 CO2 ACO2 SD TYR2 ACO2 SD U T YR2 0 2000 5000 1 0 10 1501 7110 1000 300 ATM CO2 SD TYR2 ATM CO2 SD U T YR2 0 2000 5000 1 0 50 C 0 10 0 10 1...

Страница 14: ...r 10 95 10 50 C ZVEI VDE EMV 0 10 0 UB 15 36 UB GND 24 Circuitry Circuitry 0 10V 0V GND 0 10V 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power supply AC 24V 0V DC 15 36V GND...

Страница 15: ...ther and sun protection optional Protection contre les intemp ries et le soleil en option Copyright by S S Regeltechnik GmbH Nachdruck auch auszugsweise nur mit Genehmigung von S S Regeltechnik GmbH g...

Страница 16: ...usgang CO2 0 10V in ppm UB GND 1 2 3 4 5 6 UB 24V AC DC Ausgang CO2 0 10V in ppm UB GND GND n c in C Ausgang Temperatur 0 10V OFFSET C CO 1 ON DIP 1 2 3 4 5 6 Ausgang Temperatur in C n c GND CO Sensor...

Отзывы: