SITE SELECTION
CHOOSE YOUR INSTALLATION CAREFULLY!
The Intelliscan Six Zone should be installed
on a level, solid floor. There should be no large metal objects within 3 feet of the unit. Intelliscan
is designed to detect metal that is moving, hence, closely spaced large metal objects such metal
clad doors, passing metal carts or fork lifts, etc.
will cause
an alarm event. Choose your
installation site carefully to minimize disturbances from large moving metal objects in the
surrounding area. Likewise,
care should be taken not to position the unit too close to walls
which contain rebar construction or conduit.
If the unit must be used near stationary metal the
Horizontal Axis Gain Control feature can be used to compensate for signal losses.
Use a Model
1000 Hand scanner to scan walls for the presence of substantial amount of metal.
Plan screening area with enough room to accommodate people waiting to pass through the unit,
space for operators, and a non-metallic table for depositing objects removed from pockets and
area for hand scanning. Make sure the unit will not get exposed to rain, mist or condensation.
Insure the power cord is routed away from pedestrian traffic.
5.0.
USING THE INTELLISCAN SIX ZONE
Intelliscan has an Alarm Display Panel with an L.E.D. array, an L.C.D. alpha-numeric
display and a 20 button Keypad. The L.C.D. display and keypad allow the user to adjust
operating parameters and to tailor the unit’s operation to meet his/her specific security
requirements. The Alarm Display provides information on alarm events, signal strength,
and abnormal conditions such as high noise and / or metal overload conditions.
Turn the unit on by inserting the key into the Key switch and turning it clockwise. All the
L.E.D. elements light up in sequence one at a time. The L.C.D. Panel displays a SELF-
TEST message while a self-diagnostic test is in progress. Next it reads CALIBRATION.
During this period the unit calibrates itself to its surrounding environment (
always keep
moving metal objects and people clear of the unit when it is undergoing calibration.)
If any disturbance to the surrounding environment occurs during SELF-TEST or
CALIBRATION (e.g. a metal cart is moved by the unit, person touches the unit, person
walks through it, etc.) the unit must be returned to SELF-TEST mode. To reset, press the
“
Rst”
(Reset) key on the Keypad. Alternative, turn the AC power off and then back on; it
then automatically self-test and recalibrates.
When the unit has completed testing and calibrating the L.C.D. continuously scrolls and
shows: model and version number. Intelliscan performs all normal screening operations
in this operating mode. Adjustments to the operating parameters settings cannot be made
in this program mode; for example, sensitivity values cannot be accessed. Security
screening should always be performed in this mode.
Operating parameters can only be accessed by an authorized person. Entry into the
operating menu is gained by entering a six-digit pass-code via the keypad. If, after
accessing the menu no keypad changes are made within a five minute period, access to
the operating parameters is automatically terminated. The default pass-code key strokes
are
1, 2, 3, 4, 5, 6
and
Ent
(Enter).