DST-64T / DST642D Wheel Balancers
49
P/N 5900192 — Rev. F — March 2021
Calibrating the Inner Arm
The Inner Arm Calibration makes sure the Inner Arm is returning correct values.
Note
: The Balancer comes from the factory correctly calibrated. You do not need to perform this
calibration when you receive the Balancer. You only need to perform this calibration if you are
seeing multiple incorrect Wheel balances.
Perform this procedure
without
a mounted Wheel.
To calibrate the Inner Arm / Distance Ruler
:
Press
and hold
Stop
, then press
<5g
.
CAL-100-dIS
appears.
Pull out the Distance Ruler to
10
cm and hold it there, then press
ALU
.
CAL-235-dIS
appears.
Pull out the Distance Ruler to
23.5
and hold it there, rest the Head against the Shaft Flange, then
press
ALU
.
CAL 15.0
appears.
Mount a 15" to 17" diameter Wheel onto the Threaded Shaft.
Set the
15.0
to the actual diameter of the Wheel you just mounted, then press
ALU
.
If you mounted a 15" diameter Wheel, you don’t have to change anything.
Put the Head of the Distance Ruler on the Inner Edge of the Wheel, then press
ALU
.
Calibration is complete.